These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 20589032)

  • 1. Self-mixing flow sensor using a monolithic VCSEL array with parallel readout.
    Lim YL; Kliese R; Bertling K; Tanimizu K; Jacobs PA; Rakić AD
    Opt Express; 2010 May; 18(11):11720-7. PubMed ID: 20589032
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Self-mixing imaging sensor using a monolithic VCSEL array with parallel readout.
    Lim YL; Nikolic M; Bertling K; Kliese R; Rakić AD
    Opt Express; 2009 Mar; 17(7):5517-25. PubMed ID: 19333319
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electroosmotic mixing in microchannels.
    Glasgow I; Batton J; Aubry N
    Lab Chip; 2004 Dec; 4(6):558-62. PubMed ID: 15570365
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microfluidic pH-sensing chips integrated with pneumatic fluid-control devices.
    Lin CF; Lee GB; Wang CH; Lee HH; Liao WY; Chou TC
    Biosens Bioelectron; 2006 Feb; 21(8):1468-75. PubMed ID: 16099154
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sample flow switching techniques on microfluidic chips.
    Pan YJ; Lin JJ; Luo WJ; Yang RJ
    Biosens Bioelectron; 2006 Feb; 21(8):1644-8. PubMed ID: 16112854
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Magnetic-based microfluidic platform for biomolecular separation.
    Ramadan Q; Samper V; Poenar D; Yu C
    Biomed Microdevices; 2006 Jun; 8(2):151-8. PubMed ID: 16688574
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Self-mixing in multi-transverse mode semiconductor lasers: model and potential application to multi-parametric sensing.
    Columbo L; Brambilla M; Dabbicco M; Scamarcio G
    Opt Express; 2012 Mar; 20(6):6286-305. PubMed ID: 22418511
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Self-mixing sensing system based on uncooled vertical-cavity surface-emitting laser array: linking multichannel operation and enhanced performance.
    Tucker JR; Mowla A; Herbert J; Fuentes MA; Freakley CS; Bertling K; Lim YL; Matharu RS; Perchoux J; Taimre T; Wilson SJ; Rakić AD
    Opt Lett; 2014 Jan; 39(2):394-7. PubMed ID: 24562155
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Photoacoustic imaging velocimetry for flow-field measurement.
    Ma S; Yang S; Xing D
    Opt Express; 2010 May; 18(10):9991-10000. PubMed ID: 20588853
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The golden-mean surface pattern to enhance flow mixing in micro-channel.
    Wang JF; Liu Y; Xu YS
    Biomed Microdevices; 2009 Apr; 11(2):351-7. PubMed ID: 18850319
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hydrodynamic focusing of conducting fluids for conductivity-based biosensors.
    Nasir M; Ateya DA; Burk D; Golden JP; Ligler FS
    Biosens Bioelectron; 2010 Feb; 25(6):1363-9. PubMed ID: 19932019
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simulation of two-dimensional fully developed laminar flow for a magneto-hydrodynamic (MHD) pump.
    Wang PJ; Chang CY; Chang ML
    Biosens Bioelectron; 2004 Jul; 20(1):115-21. PubMed ID: 15142583
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electrothermal stirring for heterogeneous immunoassays.
    Sigurdson M; Wang D; Meinhart CD
    Lab Chip; 2005 Dec; 5(12):1366-73. PubMed ID: 16286967
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A generic-tee-plenum mixing system for application to single point aerosol sampling in stacks and ducts.
    Han T; O'Neal DL; Ortiz CA
    Health Phys; 2007 Jan; 92(1):40-9. PubMed ID: 17164598
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficient micromixing of a highly viscous biosample with water using orbital shaking and microchannels.
    Yuan L; Zheng YF; Chen W
    Rev Sci Instrum; 2010 May; 81(5):054301. PubMed ID: 20515156
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multiwell micromechanical cantilever array reader for biotechnology.
    Zhang R; Best A; Berger R; Cherian S; Lorenzoni S; Macis E; Raiteri R; Cain R
    Rev Sci Instrum; 2007 Aug; 78(8):084103. PubMed ID: 17764339
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A digital microfluidic platform for the automation of quantitative biomolecular assays.
    Jensen EC; Bhat BP; Mathies RA
    Lab Chip; 2010 Mar; 10(6):685-91. PubMed ID: 20221555
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High performance microfluidic capillary electrophoresis devices.
    Fu LM; Leong JC; Lin CF; Tai CH; Tsai CH
    Biomed Microdevices; 2007 Jun; 9(3):405-12. PubMed ID: 17487587
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Combining multiple optical trapping with microflow manipulation for the rapid bioanalytics on microparticles in a chip.
    Boer G; Johann R; Rohner J; Merenda F; Delacrétaz G; Renaud P; Salathé RP
    Rev Sci Instrum; 2007 Nov; 78(11):116101. PubMed ID: 18052509
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spectrally resolved flow imaging of fluids inside a microfluidic chip with ultrahigh time resolution.
    Harel E; Pines A
    J Magn Reson; 2008 Aug; 193(2):199-206. PubMed ID: 18538599
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.