These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 20594078)

  • 21. Evaluation of an indirect oscillometric blood pressure monitor in anaesthetised dogs at three different anatomical locations.
    Fujiyama M; Sano H; Chambers JP; Gieseg M
    N Z Vet J; 2017 Jul; 65(4):185-191. PubMed ID: 28514936
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of an indirect oscillometric blood pressure monitor in normotensive and hypotensive anesthetized dogs.
    Shih A; Robertson S; Vigani A; da Cunha A; Pablo L; Bandt C
    J Vet Emerg Crit Care (San Antonio); 2010 Jun; 20(3):313-8. PubMed ID: 20636984
    [TBL] [Abstract][Full Text] [Related]  

  • 23. High Definition Oscillometry: a novel technique for non-invasive blood pressure monitoring in the cynomolgus monkey (Macaca fascicularis).
    Schmelting B; Niehoff M; Egner B; Korte SH; Weinbauer GF
    J Med Primatol; 2009 Oct; 38(5):293-301. PubMed ID: 19281483
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison of CAT Doppler and oscillometric Memoprint machines for non-invasive blood pressure measurement in conscious cats.
    Jepson RE; Hartley V; Mendl M; Caney SM; Gould DJ
    J Feline Med Surg; 2005 Jun; 7(3):147-52. PubMed ID: 15922221
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of blood pressure measurements obtained in dogs by use of indirect oscillometry in a veterinary clinic versus at home.
    Kallet AJ; Cowgill LD; Kass PH
    J Am Vet Med Assoc; 1997 Mar; 210(5):651-4. PubMed ID: 9054993
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of high-definition and conventional oscillometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines.
    Wernick M; Doherr M; Howard J; Francey T
    J Small Anim Pract; 2010 Jun; 51(6):318-24. PubMed ID: 20492450
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of direct and indirect blood pressure measurements in anesthetized dogs.
    Gains MJ; Grodecki KM; Jacobs RM; Dyson D; Foster RA
    Can J Vet Res; 1995 Jul; 59(3):238-40. PubMed ID: 8521360
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of noninvasive oscillometric blood pressure monitoring in anesthetized boid snakes.
    Chinnadurai SK; Wrenn A; DeVoe RS
    J Am Vet Med Assoc; 2009 Mar; 234(5):625-30. PubMed ID: 19250041
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of telemetry and high-definition oscillometry for blood pressure measurements in conscious dogs: effects of torcetrapib.
    Meyer O; Jenni R; Greiter-Wilke A; Breidenbach A; Holzgrefe HH
    J Am Assoc Lab Anim Sci; 2010 Jul; 49(4):464-71. PubMed ID: 20819394
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Sensitivity of two noninvasive blood pressure measurement techniques compared to telemetry in cynomolgus monkeys and beagle dogs.
    Mitchell AZ; McMahon C; Beck TW; Sarazan RD
    J Pharmacol Toxicol Methods; 2010; 62(1):54-63. PubMed ID: 20435151
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs.
    Vachon C; Belanger MC; Burns PM
    Res Vet Sci; 2014 Aug; 97(1):111-7. PubMed ID: 24924217
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A clinical comparison between a non-invasive blood pressure monitor using high definition oscillometry (Memodiagnostic MD 15/90 Pro) and invasive arterial blood pressure measurement in anaesthetized dogs.
    Rysnik MK; Cripps P; Iff I
    Vet Anaesth Analg; 2013 Sep; 40(5):503-11. PubMed ID: 23565863
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.
    Acierno MJ; da Cunha A; Smith J; Tully TN; Guzman DS; Serra V; Mitchell MA
    J Am Vet Med Assoc; 2008 Nov; 233(10):1587-90. PubMed ID: 19014291
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Oscillometric and Doppler arterial blood pressure measurement in conscious goats.
    Szaluś-Jordanow O; Czopowicz M; Świerk A; Szpinda O; Garncarz M; Mickiewicz M; Moroz A; Bagnicka E; Kaba J
    Can J Vet Res; 2018 Oct; 82(4):244-248. PubMed ID: 30363283
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of how well conscious cats tolerate blood pressure measurement from the radial and coccygeal arteries.
    Cannon MJ; Brett J
    J Feline Med Surg; 2012 Dec; 14(12):906-9. PubMed ID: 22832888
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Doppler and oscillometric mean blood pressure best represent direct blood pressure measurements in anesthetized rhesus macaques (Macaca mulatta).
    Kang SC; Jampachaisri K; Pacharinsak C
    J Med Primatol; 2019 Apr; 48(2):123-128. PubMed ID: 30644561
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Adaptation of human oscillometric blood pressure monitors for use in dogs.
    Hunter JS; McGrath CJ; Thatcher CD; Remillard RL; McCain WC
    Am J Vet Res; 1990 Sep; 51(9):1439-42. PubMed ID: 2396790
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Indirect arterial blood pressure measurement in nonsedated Irish wolfhounds: reference values for the breed.
    Bright JM; Dentino M
    J Am Anim Hosp Assoc; 2002; 38(6):521-6. PubMed ID: 12428882
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of the automated oscillometric method with the gold standard Doppler ultrasound method to access the ankle-brachial pressure index.
    Hamel JF; Foucaud D; Fanello S
    Angiology; 2010 Jul; 61(5):487-91. PubMed ID: 20211935
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of two species-specific oscillometric blood pressure monitors with direct blood pressure measurement in anesthetized cats.
    Cerejo SA; Teixeira-Neto FJ; Garofalo NA; Rodrigues JC; Celeita-Rodríguez N; Lagos-Carvajal AP
    J Vet Emerg Crit Care (San Antonio); 2017 Jul; 27(4):409-418. PubMed ID: 28654723
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.