243 related articles for article (PubMed ID: 20598204)
1. Imaging, core-loss, and low-loss electron-energy-loss spectroscopy mapping in aberration-corrected STEM.
Lazar S; Shao Y; Gunawan L; Nechache R; Pignolet A; Botton GA
Microsc Microanal; 2010 Aug; 16(4):416-24. PubMed ID: 20598204
[TBL] [Abstract][Full Text] [Related]
2. Local analysis of the edge dislocation core in BaTiO(3) thin film by STEM-EELS.
Kurata H; Isojima S; Kawai M; Shimakawa Y; Isoda S
J Microsc; 2009 Nov; 236(2):128-31. PubMed ID: 19903238
[TBL] [Abstract][Full Text] [Related]
3. Molecular mapping by low-energy-loss energy-filtered transmission electron microscopy imaging.
Linares EM; Leite CA; Valadares LF; Silva CA; Rezende CA; Galembeck F
Anal Chem; 2009 Mar; 81(6):2317-24. PubMed ID: 19222212
[TBL] [Abstract][Full Text] [Related]
4. Study of atomic resolved plasmon-loss image by spherical aberration-corrected STEM-EELS method.
Yamazaki T; Kotaka Y; Tsukada M; Kataoka Y
Ultramicroscopy; 2010 Aug; 110(9):1161-5. PubMed ID: 20451326
[TBL] [Abstract][Full Text] [Related]
5. Surface channeling in aberration-corrected scanning transmission electron microscopy of nanostructures.
Liu J; Allard LF
Microsc Microanal; 2010 Aug; 16(4):425-33. PubMed ID: 20598201
[TBL] [Abstract][Full Text] [Related]
6. Nanocrystalline Domain Identification in Gold Films, by Backscattered Electron Imaging and Energy-Filtered Transmission Electron Microscopy.
Leite CA; Galembeck F
J Colloid Interface Sci; 2001 Mar; 235(1):4-8. PubMed ID: 11237437
[TBL] [Abstract][Full Text] [Related]
7. Mapping of valence energy losses via energy-filtered annular dark-field scanning transmission electron microscopy.
Gu L; Sigle W; Koch CT; Nelayah J; Srot V; van Aken PA
Ultramicroscopy; 2009 Aug; 109(9):1164-70. PubMed ID: 19525066
[TBL] [Abstract][Full Text] [Related]
8. A new experimental procedure to quantify annular dark field images in scanning transmission electron microscopy.
Walther T
J Microsc; 2006 Feb; 221(Pt 2):137-44. PubMed ID: 16499552
[TBL] [Abstract][Full Text] [Related]
9. Local boron environment in B-doped nanocrystalline diamond films.
Turner S; Lu YG; Janssens SD; Da Pieve F; Lamoen D; Verbeeck J; Haenen K; Wagner P; Van Tendeloo G
Nanoscale; 2012 Sep; 4(19):5960-4. PubMed ID: 22903371
[TBL] [Abstract][Full Text] [Related]
10. Fine structural features of nanoscale zero-valent iron characterized by spherical aberration corrected scanning transmission electron microscopy (Cs-STEM).
Liu A; Zhang WX
Analyst; 2014 Sep; 139(18):4512-8. PubMed ID: 25050411
[TBL] [Abstract][Full Text] [Related]
11. Valence state map of iron oxide thin film obtained from electron spectroscopy imaging series.
Chen KF; Lo SC; Chang L; Egerton R; Kai JJ; Lin JJ; Chen FR
Micron; 2007; 38(4):354-61. PubMed ID: 16934475
[TBL] [Abstract][Full Text] [Related]
12. The formation and utility of sub-angstrom to nanometer-sized electron probes in the aberration-corrected transmission electron microscope at the University of Illinois.
Wen J; Mabon J; Lei C; Burdin S; Sammann E; Petrov I; Shah AB; Chobpattana V; Zhang J; Ran K; Zuo JM; Mishina S; Aoki T
Microsc Microanal; 2010 Apr; 16(2):183-93. PubMed ID: 20187990
[TBL] [Abstract][Full Text] [Related]
13. Depth sectioning in scanning transmission electron microscopy based on core-loss spectroscopy.
D'Alfonso AJ; Findlay SD; Oxley MP; Pennycook SJ; van Benthem K; Allen LJ
Ultramicroscopy; 2007 Dec; 108(1):17-28. PubMed ID: 17395376
[TBL] [Abstract][Full Text] [Related]
14. Application of two-dimensional crystallography and image processing to atomic resolution Z-contrast images.
Morgan DG; Ramasse QM; Browning ND
J Electron Microsc (Tokyo); 2009 Jun; 58(3):223-44. PubMed ID: 19297343
[TBL] [Abstract][Full Text] [Related]
15. Lattice imaging in low-angle and high-angle bright-field scanning transmission electron microscopy.
Watanabe K; Kikuchi Y; Yamazaki T; Asano E; Nakanishi N; Kotaka Y; Okunishi E; Hashimoto I
Acta Crystallogr A; 2004 Nov; 60(Pt 6):591-7. PubMed ID: 15507742
[TBL] [Abstract][Full Text] [Related]
16. Evaluation and optimization of the performance of elastic and inelastic scanning transmission electron microscope imaging by correlation analysis.
Mory C; Bonnet N; Colliex C; Kohl H; Tencé M
Scanning Microsc Suppl; 1988; 2():329-42. PubMed ID: 3244971
[TBL] [Abstract][Full Text] [Related]
17. Low-energy-loss EFTEM imaging of thick particles and aggregates.
Valadares LF; do Carmo Bragança F; da Silva CA; Leite CA; Galembeck F
J Colloid Interface Sci; 2007 May; 309(1):140-8. PubMed ID: 17286981
[TBL] [Abstract][Full Text] [Related]
18. Sub-nanometre elemental analysis of Cu cluster in Fe-Cu-Ni alloy using aberration corrected STEM-EDS.
Nakamichi H; Yamada K; Sato K
J Microsc; 2011 Apr; 242(1):55-61. PubMed ID: 21118232
[TBL] [Abstract][Full Text] [Related]
19. Effects of tilt on high-resolution ADF-STEM imaging.
Maccagnano-Zacher SE; Mkhoyan KA; Kirkland EJ; Silcox J
Ultramicroscopy; 2008 Jul; 108(8):718-26. PubMed ID: 18160220
[TBL] [Abstract][Full Text] [Related]
20. Direct imaging and chemical identification of the encapsulated metal atoms in bimetallic endofullerene peapods.
Nicholls RJ; Sader K; Warner JH; Plant SR; Porfyrakis K; Nellist PD; Briggs GA; Cockayne DJ
ACS Nano; 2010 Jul; 4(7):3943-8. PubMed ID: 20557070
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]