These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 20598261)

  • 1. Single-balloon-assisted colonoscopy in patients with previously failed colonoscopy.
    Teshima CW; Aktas H; Haringsma J; Kuipers EJ; Mensink PB
    Gastrointest Endosc; 2010 Jun; 71(7):1319-23. PubMed ID: 20598261
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Enteroscope without overtube for cecal intubation after an incomplete colonoscopy.
    Coppola F; Gaia S; Cosimato M; Recchia S
    Dig Liver Dis; 2011 Jun; 43(6):475-7. PubMed ID: 21334994
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Double-balloon colonoscopy after failed conventional colonoscopy: a pilot series with a new instrument.
    Gay G; Delvaux M
    Endoscopy; 2007 Sep; 39(9):788-92. PubMed ID: 17703387
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computer-assisted colonoscopy (the NeoGuide Endoscopy System): results of the first human clinical trial ("PACE study").
    Eickhoff A; van Dam J; Jakobs R; Kudis V; Hartmann D; Damian U; Weickert U; Schilling D; Riemann JF
    Am J Gastroenterol; 2007 Feb; 102(2):261-6. PubMed ID: 17156149
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Push-and-pull enteroscopy using a single-balloon technique for difficult colonoscopy.
    May A; Nachbar L; Ell C
    Endoscopy; 2006 Apr; 38(4):395-8. PubMed ID: 16680641
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Usefulness of the double-balloon enteroscope in colonoscopies performed in patients with previously failed colonoscopy.
    Mönkemüller K; Knippig C; Rickes S; Fry LC; Schulze A; Malfertheiner P
    Scand J Gastroenterol; 2007 Feb; 42(2):277-8. PubMed ID: 17327949
    [No Abstract]   [Full Text] [Related]  

  • 7. Technical considerations and patient comfort in total colonoscopy with and without a transparent cap: initial experiences from a pilot study.
    Dafnis GM
    Endoscopy; 2000 May; 32(5):381-4. PubMed ID: 10817176
    [TBL] [Abstract][Full Text] [Related]  

  • 8. How to approach the small bowel with flexible enteroscopy.
    May A
    Gastroenterol Clin North Am; 2010 Dec; 39(4):797-806. PubMed ID: 21093756
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Short double-balloon enteroscope for previously failed colonoscopy.
    Matsushita M; Shimatani M; Tanaka T; Fukata N; Kawamata S; Okazaki K
    Gastrointest Endosc; 2011 Apr; 73(4):854-5; author reply 855. PubMed ID: 21457831
    [No Abstract]   [Full Text] [Related]  

  • 10. Double-balloon endoscopy versus magnet-imaging enhanced colonoscopy for difficult colonoscopies, a randomized study.
    Suzuki T; Matsushima M; Tsukune Y; Fujisawa M; Yazaki T; Uchida T; Gocyo S; Okita I; Shirakura K; Sasao K; Saito T; Sakamoto I; Igarashi M; Koike J; Takagi A; Mine T
    Endoscopy; 2012 Jan; 44(1):38-42. PubMed ID: 22143991
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Obscure GI bleeding in the tropics: impact of introduction of double-balloon and capsule endoscopies on outcome.
    Das K; Sarkar R; Dasgupta J; Ray S; Ghatak S; Das K; Mridha AR; Dhali GK; Chowdhury A
    Gastrointest Endosc; 2010 Aug; 72(2):292-300. PubMed ID: 20541203
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effective dilation of small-bowel strictures by double-balloon enteroscopy in patients with symptomatic Crohn's disease (with video).
    Despott EJ; Gupta A; Burling D; Tripoli E; Konieczko K; Hart A; Fraser C
    Gastrointest Endosc; 2009 Nov; 70(5):1030-6. PubMed ID: 19640518
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Testing the procedure for virtual colonoscopy and its possible place in the algorithm of study of colonic diseases].
    Klimova NV; Darvin VV; Il'kanich AIa; Vasil'ev VV; Shurygina IL; Chrnobaĭ SIu
    Vestn Rentgenol Radiol; 2007; (3):46-53. PubMed ID: 18557354
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of a double balloon enteroscope facilitates caecal intubation after incomplete colonoscopy with a standard colonoscope.
    Kaltenbach T; Soetikno R; Friedland S
    Dig Liver Dis; 2006 Dec; 38(12):921-5. PubMed ID: 16990055
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Complications of single-balloon enteroscopy: a prospective evaluation of 166 procedures.
    Aktas H; de Ridder L; Haringsma J; Kuipers EJ; Mensink PB
    Endoscopy; 2010 May; 42(5):365-8. PubMed ID: 20178072
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnostic yield and therapeutic impact of double-balloon enteroscopy in a large cohort of patients with obscure gastrointestinal bleeding.
    Sun B; Rajan E; Cheng S; Shen R; Zhang C; Zhang S; Wu Y; Zhong J
    Am J Gastroenterol; 2006 Sep; 101(9):2011-5. PubMed ID: 16848814
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Artificial bowel markers: a novel method for measuring the accuracy of colonoscopy.
    Beckly JB; Douie WJ; Hayward CM; Oppong CF; Coleman MG; Beckly DE; Hosie KB
    Dis Colon Rectum; 2007 Jul; 50(7):1047-52. PubMed ID: 17279301
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The status of colonoscopy in a surgical practice].
    Gresser A; Daiber D; Guggenmos H
    Fortschr Med; 1981 Jun; 99(23):912-6. PubMed ID: 7262774
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Novel single-balloon enteroscopy for diagnosis and treatment of the small intestine: preliminary experiences.
    Tsujikawa T; Saitoh Y; Andoh A; Imaeda H; Hata K; Minematsu H; Senoh K; Hayafuji K; Ogawa A; Nakahara T; Sasaki M; Fujiyama Y
    Endoscopy; 2008 Jan; 40(1):11-5. PubMed ID: 18058613
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The measurement of forces exerted during colonoscopy.
    Appleyard MN; Mosse CA; Mills TN; Bell GD; Castillo FD; Swain CP
    Gastrointest Endosc; 2000 Aug; 52(2):237-40. PubMed ID: 10922101
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.