These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 2060287)

  • 1. The median filter as a preprocessor for a patient monitor limit alarm system in intensive care.
    Mäkivirta A; Koski E; Kari A; Sukuvaara T
    Comput Methods Programs Biomed; 1991; 34(2-3):139-44. PubMed ID: 2060287
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A knowledge-based alarm system for monitoring cardiac operated patients--technical construction and evaluation.
    Sukuvaara T; Koski EM; Mäkivirta A; Kari A
    Int J Clin Monit Comput; 1993 May; 10(2):117-26. PubMed ID: 8366312
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Frequency and reliability of alarms in the monitoring of cardiac postoperative patients.
    Koski EM; Mäkivirta A; Sukuvaara T; Kari A
    Int J Clin Monit Comput; 1990 Apr; 7(2):129-33. PubMed ID: 2373943
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Insights into the problem of alarm fatigue with physiologic monitor devices: a comprehensive observational study of consecutive intensive care unit patients.
    Drew BJ; Harris P; Zègre-Hemsey JK; Mammone T; Schindler D; Salas-Boni R; Bai Y; Tinoco A; Ding Q; Hu X
    PLoS One; 2014; 9(10):e110274. PubMed ID: 25338067
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia: Theoretical effects of artifact rejection, alarm delay, averaging, median filtering or a lower setting of the alarm limit.
    Rheineck-Leyssius AT; Kalkman CJ
    J Clin Monit Comput; 1998 Apr; 14(3):151-6. PubMed ID: 9676861
    [TBL] [Abstract][Full Text] [Related]  

  • 6. False alarms during patient monitoring in clinical intensive care units are highly related to poor quality of the monitored electrocardiogram signals.
    Tsimenidis C; Murray A
    Physiol Meas; 2016 Aug; 37(8):1383-91. PubMed ID: 27454130
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Physiologic monitoring alarm load on medical/surgical floors of a community hospital.
    Gross B; Dahl D; Nielsen L
    Biomed Instrum Technol; 2011; Suppl():29-36. PubMed ID: 21599479
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Testing physiologic monitor alarm customization software to reduce alarm rates and improve nurses' experience of alarms in a medical intensive care unit.
    Ruppel H; De Vaux L; Cooper D; Kunz S; Duller B; Funk M
    PLoS One; 2018; 13(10):e0205901. PubMed ID: 30335824
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improving alarm performance in the medical intensive care unit using delays and clinical context.
    Görges M; Markewitz BA; Westenskow DR
    Anesth Analg; 2009 May; 108(5):1546-52. PubMed ID: 19372334
    [TBL] [Abstract][Full Text] [Related]  

  • 10. False alarm reduction in critical care.
    Clifford GD; Silva I; Moody B; Li Q; Kella D; Chahin A; Kooistra T; Perry D; Mark RG
    Physiol Meas; 2016 Aug; 37(8):E5-E23. PubMed ID: 27454172
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Collection of annotated data in a clinical validation study for alarm algorithms in intensive care--a methodologic framework.
    Siebig S; Kuhls S; Imhoff M; Langgartner J; Reng M; Schölmerich J; Gather U; Wrede CE
    J Crit Care; 2010 Mar; 25(1):128-35. PubMed ID: 19327311
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Suppression of false arrhythmia alarms in the ICU: a machine learning approach.
    Ansari S; Belle A; Ghanbari H; Salamango M; Najarian K
    Physiol Meas; 2016 Aug; 37(8):1186-203. PubMed ID: 27454017
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel algorithm for reducing false arrhythmia alarms in intensive care units.
    Srivastava C; Sharma S; Jalali A
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():2525-2528. PubMed ID: 28268837
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reducing false alarms in the ICU by quantifying self-similarity of multimodal biosignals.
    Antink CH; Leonhardt S; Walter M
    Physiol Meas; 2016 Aug; 37(8):1233-52. PubMed ID: 27454256
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intensive care unit alarms--how many do we need?
    Siebig S; Kuhls S; Imhoff M; Gather U; Schölmerich J; Wrede CE
    Crit Care Med; 2010 Feb; 38(2):451-6. PubMed ID: 20016379
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reducing false alarms of intensive care online-monitoring systems: an evaluation of two signal extraction algorithms.
    Borowski M; Siebig S; Wrede C; Imhoff M
    Comput Math Methods Med; 2011; 2011():143480. PubMed ID: 21461385
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An expert system for monitor alarm integration.
    Oberli C; Urzua J; Saez C; Guarini M; Ciprianio A; Garayar B; Lema G; Canessa R; Sacco C; Irarrazaval M
    J Clin Monit Comput; 1999 Jan; 15(1):29-35. PubMed ID: 12578059
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intra-operative monitoring--many alarms with minor impact.
    de Man FR; Greuters S; Boer C; Veerman DP; Loer SA
    Anaesthesia; 2013 Aug; 68(8):804-10. PubMed ID: 23745968
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Making ICU alarms meaningful: a comparison of traditional vs. trend-based algorithms.
    Schoenberg R; Sands DZ; Safran C
    Proc AMIA Symp; 1999; ():379-83. PubMed ID: 10566385
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real-time arrhythmia detection with supplementary ECG quality and pulse wave monitoring for the reduction of false alarms in ICUs.
    Krasteva V; Jekova I; Leber R; Schmid R; Abächerli R
    Physiol Meas; 2016 Aug; 37(8):1273-97. PubMed ID: 27454550
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.