260 related articles for article (PubMed ID: 20604524)
21. Scanning electrochemical microscope observation of defects in a hexadecanethiol monolayer on gold with shear force-based tip-substrate positioning.
Yamada H; Ogata M; Koike T
Langmuir; 2006 Aug; 22(18):7923-7. PubMed ID: 16922585
[TBL] [Abstract][Full Text] [Related]
22. Imaging immobilised ssDNA and detecting DNA hybridisation by means of the repelling mode of scanning electrochemical microscopy (SECM).
Turcu F; Schulte A; Hartwich G; Schuhmann W
Biosens Bioelectron; 2004 Nov; 20(5):925-32. PubMed ID: 15530789
[TBL] [Abstract][Full Text] [Related]
23. Properties of hybridized DNA arrays on single-crystalline undoped and boron-doped (100) diamonds studied by atomic force microscopy in electrolytes.
Rezek B; Shin D; Nebel CE
Langmuir; 2007 Jul; 23(14):7626-33. PubMed ID: 17547423
[TBL] [Abstract][Full Text] [Related]
24. 4D shearforce-based constant-distance mode scanning electrochemical microscopy.
Nebel M; Eckhard K; Erichsen T; Schulte A; Schuhmann W
Anal Chem; 2010 Sep; 82(18):7842-8. PubMed ID: 20735144
[TBL] [Abstract][Full Text] [Related]
25. AFM nanometer surface morphological study of in situ electropolymerized neutral red redox mediator oxysilane sol-gel encapsulated glucose oxidase electrochemical biosensors.
Chiorcea-Paquim AM; Pauliukaite R; Brett CM; Oliveira-Brett AM
Biosens Bioelectron; 2008 Oct; 24(2):297-305. PubMed ID: 18485690
[TBL] [Abstract][Full Text] [Related]
26. Conductive supports for combined AFM-SECM on biological membranes.
Frederix PL; Bosshart PD; Akiyama T; Chami M; Gullo MR; Blackstock JJ; Dooleweerdt K; de Rooij NF; Staufer U; Engel A
Nanotechnology; 2008 Sep; 19(38):384004. PubMed ID: 21832564
[TBL] [Abstract][Full Text] [Related]
27. Grafting of single, stimuli-responsive poly(ferrocenylsilane) polymer chains to gold surfaces.
Zou S; Ma Y; Hempenius MA; Schönherr H; Vancso GJ
Langmuir; 2004 Jul; 20(15):6278-87. PubMed ID: 15248713
[TBL] [Abstract][Full Text] [Related]
28. Monolayers and multilayers of conjugated polymers as nanosized electronic components.
Zotti G; Vercelli B; Berlin A
Acc Chem Res; 2008 Sep; 41(9):1098-109. PubMed ID: 18570441
[TBL] [Abstract][Full Text] [Related]
29. Fabrication and characterization of contact lenses bearing surface-immobilized layers of intact liposomes.
Danion A; Brochu H; Martin Y; Vermette P
J Biomed Mater Res A; 2007 Jul; 82(1):41-51. PubMed ID: 17265438
[TBL] [Abstract][Full Text] [Related]
30. Hopping intermittent contact-scanning electrochemical microscopy (HIC-SECM): visualizing interfacial reactions and fluxes from surfaces to bulk solution.
Lazenby RA; McKelvey K; Unwin PR
Anal Chem; 2013 Mar; 85(5):2937-44. PubMed ID: 23373422
[TBL] [Abstract][Full Text] [Related]
31. Synthesis and electrografting of dendron anchored OEGylated surfaces and their protein adsorption resistance.
Felipe MJ; Ponnapati RR; Pernites RB; Dutta P; Advincula RC
ACS Appl Mater Interfaces; 2010 Dec; 2(12):3401-5. PubMed ID: 21077629
[TBL] [Abstract][Full Text] [Related]
32. Intermittent contact-scanning electrochemical microscopy (IC-SECM): a new approach for tip positioning and simultaneous imaging of interfacial topography and activity.
McKelvey K; Edwards MA; Unwin PR
Anal Chem; 2010 Aug; 82(15):6334-7. PubMed ID: 20583818
[TBL] [Abstract][Full Text] [Related]
33. Characterization of batch-microfabricated scanning electrochemical-atomic force microscopy probes.
Dobson PS; Weaver JM; Holder MN; Unwin PR; Macpherson JV
Anal Chem; 2005 Jan; 77(2):424-34. PubMed ID: 15649037
[TBL] [Abstract][Full Text] [Related]
34. Mapping of enzyme activity by detection of enzymatic products during AFM imaging with integrated SECM-AFM probes.
Kranz C; Kueng A; Lugstein A; Bertagnolli E; Mizaikoff B
Ultramicroscopy; 2004 Aug; 100(3-4):127-34. PubMed ID: 15231302
[TBL] [Abstract][Full Text] [Related]
35. Scanning electrochemical microscopy combined with surface plasmon resonance: studies of localized film thickness variations and molecular conformation changes.
Xiang J; Guo J; Zhou F
Anal Chem; 2006 Mar; 78(5):1418-24. PubMed ID: 16503589
[TBL] [Abstract][Full Text] [Related]
36. Dense passivating poly(ethylene glycol) films on indium tin oxide substrates.
Schlapak R; Armitage D; Saucedo-Zeni N; Hohage M; Howorka S
Langmuir; 2007 Sep; 23(20):10244-53. PubMed ID: 17715951
[TBL] [Abstract][Full Text] [Related]
37. Atomic force microscopy with nanoelectrode tips for high resolution electrochemical, nanoadhesion and nanoelectrical imaging.
Nellist MR; Chen Y; Mark A; Gödrich S; Stelling C; Jiang J; Poddar R; Li C; Kumar R; Papastavrou G; Retsch M; Brunschwig BS; Huang Z; Xiang C; Boettcher SW
Nanotechnology; 2017 Mar; 28(9):095711. PubMed ID: 28139467
[TBL] [Abstract][Full Text] [Related]
38. Cleavage-sensing redox peptide monolayers for the rapid measurement of the proteolytic activity of trypsin and alpha-thrombin enzymes.
Adjémian J; Anne A; Cauet G; Demaille C
Langmuir; 2010 Jun; 26(12):10347-56. PubMed ID: 20329721
[TBL] [Abstract][Full Text] [Related]
39. Fabrication and characterization of a nanometer-sized optical fiber electrode based on selective chemical etching for scanning electrochemical/optical microscopy.
Maruyama K; Ohkawa H; Ogawa S; Ueda A; Niwa O; Suzuki K
Anal Chem; 2006 Mar; 78(6):1904-12. PubMed ID: 16536427
[TBL] [Abstract][Full Text] [Related]
40. Controlling the supramolecular assembly of redox-active dendrimers at molecular printboards by scanning electrochemical microscopy.
Nijhuis CA; Sinha JK; Wittstock G; Huskens J; Ravoo BJ; Reinhoudt DN
Langmuir; 2006 Nov; 22(23):9770-5. PubMed ID: 17073510
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]