143 related articles for article (PubMed ID: 20609436)
1. Lumbopelvic fracture-dislocation combined with unstable pelvic ring injury: one stage stabilisation with spinal instrumentation.
Soultanis K; Karaliotas GI; Mastrokalos D; Sakellariou VI; Starantzis KA; Soucacos PN
Injury; 2011 Oct; 42(10):1179-83. PubMed ID: 20609436
[No Abstract] [Full Text] [Related]
2. Traumatic spondylopelvic dissociation. A report of two cases.
Vresilovic EJ; Mehta S; Placide R; Milam RA
J Bone Joint Surg Am; 2005 May; 87(5):1098-103. PubMed ID: 15866975
[No Abstract] [Full Text] [Related]
3. Fracture-dislocation of the sacroiliac joint with severely unstable fractures of the pelvis and femur in a 16-month-old patient: a case report.
Shi Q; Wu W; Han J; Dai S; Tan W; Li X
J Orthop Sci; 2015 Nov; 20(6):1127-31. PubMed ID: 25196791
[No Abstract] [Full Text] [Related]
4. Unstable pelvic ring disruptions in unstable patients.
Kregor PJ; Routt ML
Injury; 1999; 30 Suppl 2():B19-28. PubMed ID: 10562857
[TBL] [Abstract][Full Text] [Related]
5. [Unstable pelvic ring fracture: osteosynthesis of the posterior lesion by percutaneous sacroiliac fixation].
Tayot O; Meusnier T; Fessy MH; Beguin L; Carret JP; Bejui J
Rev Chir Orthop Reparatrice Appar Mot; 2001 Jun; 87(4):320-30. PubMed ID: 11431627
[TBL] [Abstract][Full Text] [Related]
6. [Triangular vertebropelvine stabilisation of unstable posterior pelvic ring fractures].
Tiemann AH; Schmidt C; Josten C
Zentralbl Chir; 2003 Mar; 128(3):202-8. PubMed ID: 12695926
[TBL] [Abstract][Full Text] [Related]
7. Unstable pediatric sacral fracture with bone loss caused by a high-energy gunshot injury.
Schildhauer TA; Bellabarba C; Selznick HS; McRoberts D; Vedder NB; Chapman JR
J Trauma; 2007 Oct; 63(4):E95-9. PubMed ID: 17308489
[No Abstract] [Full Text] [Related]
8. Computed tomography-guided screw fixation of a sacroiliac joint dislocation fracture: a case report.
Tsukushi S; Katagiri H; Nakashima H; Shido Y; Wasa J
J Orthop Sci; 2003; 8(5):729-32. PubMed ID: 14557943
[TBL] [Abstract][Full Text] [Related]
9. Less invasive lumbopelvic fixation technique using a percutaneous pedicle screw system for unstable pelvic ring fracture in a patient with severe multiple traumas.
Yano S; Aoki Y; Watanabe A; Nakajima T; Takazawa M; Hirasawa H; Takahashi K; Nakagawa K; Nakajima A; Takahashi H; Orita S; Eguchi Y; Suzuki T; Ohtori S
J Neurosurg Spine; 2017 Feb; 26(2):203-207. PubMed ID: 27716018
[TBL] [Abstract][Full Text] [Related]
10. A novel technique for stabilising sacroiliac joint dislocation using spinal instrumentation: technical notes and clinical outcomes.
Miyake T; Futamura K; Baba T; Hasegawa M; Tsuihiji K; Kanda N; Tsuchida Y; Mogami A; Obayashi O; Ogura S
Eur J Trauma Emerg Surg; 2022 Aug; 48(4):3193-3201. PubMed ID: 35022804
[TBL] [Abstract][Full Text] [Related]
11. Is there a role for percutaneous pelvic and acetabular reconstruction?
Rommens PM
Injury; 2007 Apr; 38(4):463-77. PubMed ID: 17397846
[TBL] [Abstract][Full Text] [Related]
12. Percutaneous Sacroiliac Screw Fixation of the Posterior Pelvic Ring.
Iorio JA; Jakoi AM; Rehman S
Orthop Clin North Am; 2015 Oct; 46(4):511-21. PubMed ID: 26410639
[TBL] [Abstract][Full Text] [Related]
13. One-stage percutaneous treatment in a patient with pelvic and vertebral compression fractures.
Sedat J; Chau Y; Razafidratsiva C; Bronsard N; de Peretti F
Cardiovasc Intervent Radiol; 2010 Feb; 33(1):219-22. PubMed ID: 19774411
[TBL] [Abstract][Full Text] [Related]
14. [Percutaneous sacroiliac lag screw fixation of the posterior pelvic ring. Increasing safety by standardization of visualization and insertion technique].
Tosounidis G; Culemann U; Wirbel R; Holstein JH; Pohlemann T
Unfallchirurg; 2007 Aug; 110(8):669-74. PubMed ID: 17572870
[TBL] [Abstract][Full Text] [Related]
15. Bilateral sacroiliac joint dislocation (anterior and posterior) with triradiate cartilage injury: a case report.
Lee DH; Jeong WK; Inna P; Noh W; Lee DK; Lee SH
J Orthop Trauma; 2011 Dec; 25(12):e111-4. PubMed ID: 21577148
[TBL] [Abstract][Full Text] [Related]
16. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation.
Baskin KM; Cahill AM; Kaye RD; Born CT; Grudziak JS; Towbin RB
Pediatr Radiol; 2004 Dec; 34(12):963-9. PubMed ID: 15365650
[TBL] [Abstract][Full Text] [Related]
17. Seat belt syndrome with unstable Chance fracture dislocation of the second lumbar vertebra without neurological deficits.
Onu DO; Hunn AW; Bohmer RD
BMJ Case Rep; 2014 Jan; 2014():. PubMed ID: 24403388
[TBL] [Abstract][Full Text] [Related]
18. Technique of reduction and internal fixation of thoracolumbar fracture-dislocation using pedicle screws and variable screw placement plates.
Chavda DV; Brantigan JW
Orthop Rev; 1994 May; Suppl():25-31. PubMed ID: 8090553
[TBL] [Abstract][Full Text] [Related]
19. Do Transsacral-transiliac Screws Across Uninjured Sacroiliac Joints Affect Pain and Functional Outcomes in Trauma Patients?
Heydemann J; Hartline B; Gibson ME; Ambrose CG; Munz JW; Galpin M; Achor TS; Gary JL
Clin Orthop Relat Res; 2016 Jun; 474(6):1417-21. PubMed ID: 26472585
[TBL] [Abstract][Full Text] [Related]
20. Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod.
Wang H; Fu YH; Ke C; Zhuang Y; Zhang K; Wei X; Li Z; Lei JL; Zhang BF; Liu P
Int Orthop; 2018 Mar; 42(3):681-686. PubMed ID: 29238871
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]