These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
25. Engineering microscale systems for fully autonomous intracellular neural interfaces. Kumar SS; Baker MS; Okandan M; Muthuswamy J Microsyst Nanoeng; 2020; 6():1. PubMed ID: 34567616 [TBL] [Abstract][Full Text] [Related]
26. Fabrication and characterization of polyimide-based 'smooth' titanium nitride microelectrode arrays for neural stimulation and recording. Rodrigues F; Ribeiro JF; Anacleto PA; Fouchard A; David O; Sarro PM; Mendes PM J Neural Eng; 2019 Dec; 17(1):016010. PubMed ID: 31614339 [TBL] [Abstract][Full Text] [Related]
27. Polydopamine-doped conductive polymer microelectrodes for neural recording and stimulation. Kim R; Nam Y J Neurosci Methods; 2019 Oct; 326():108369. PubMed ID: 31326604 [TBL] [Abstract][Full Text] [Related]
28. Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film. Ludwig KA; Uram JD; Yang J; Martin DC; Kipke DR J Neural Eng; 2006 Mar; 3(1):59-70. PubMed ID: 16510943 [TBL] [Abstract][Full Text] [Related]
29. Three dimensional microelectrodes enable high signal and spatial resolution for neural seizure recordings in brain slices and freely behaving animals. Wijdenes P; Haider K; Gavrilovici C; Gunning B; Wolff MD; Lijnse T; Armstrong R; Teskey GC; Rho JM; Dalton C; Syed NI Sci Rep; 2021 Nov; 11(1):21952. PubMed ID: 34754055 [TBL] [Abstract][Full Text] [Related]
31. Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex. Vetter RJ; Williams JC; Hetke JF; Nunamaker EA; Kipke DR IEEE Trans Biomed Eng; 2004 Jun; 51(6):896-904. PubMed ID: 15188856 [TBL] [Abstract][Full Text] [Related]
32. Visualization of the intact interface between neural tissue and implanted microelectrode arrays. Holecko MM; Williams JC; Massia SP J Neural Eng; 2005 Dec; 2(4):97-102. PubMed ID: 16317233 [TBL] [Abstract][Full Text] [Related]
33. High sensitivity recording of afferent nerve activity using ultra-compliant microchannel electrodes: an acute in vivo validation. Minev IR; Chew DJ; Delivopoulos E; Fawcett JW; Lacour SP J Neural Eng; 2012 Apr; 9(2):026005. PubMed ID: 22328617 [TBL] [Abstract][Full Text] [Related]
34. Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves. Davis TS; Wark HA; Hutchinson DT; Warren DJ; O'Neill K; Scheinblum T; Clark GA; Normann RA; Greger B J Neural Eng; 2016 Jun; 13(3):036001. PubMed ID: 27001946 [TBL] [Abstract][Full Text] [Related]