885 related articles for article (PubMed ID: 20622626)
61. Prevention of airway fires: do not overlook the expired oxygen concentration.
Remz M; Luria I; Gravenstein M; Rice SD; Morey TE; Gravenstein N; Rice MJ
Anesth Analg; 2013 Nov; 117(5):1172-6. PubMed ID: 23835452
[TBL] [Abstract][Full Text] [Related]
62. Nitrogen dioxide production during mechanical ventilation with nitric oxide in adults. Effects of ventilator internal volume, air versus nitrogen dilution, minute ventilation, and inspired oxygen fraction.
Nishimura M; Hess D; Kacmarek RM; Ritz R; Hurford WE
Anesthesiology; 1995 May; 82(5):1246-54. PubMed ID: 7741300
[TBL] [Abstract][Full Text] [Related]
63. Evaluation of a portable oxygen concentrator to provide fresh gas flow to dogs undergoing anesthesia.
Burn J; Caulkett NA; Gunn M; Cooney C; Kutz SJ; Boysen SR
Can Vet J; 2016 Jun; 57(6):614-8. PubMed ID: 27247461
[TBL] [Abstract][Full Text] [Related]
64. Oxygen delivery during transtracheal oxygenation: a comparison of two manual devices.
Lenfant F; Péan D; Brisard L; Freysz M; Lejus C
Anesth Analg; 2010 Oct; 111(4):922-4. PubMed ID: 20802052
[TBL] [Abstract][Full Text] [Related]
65. Influence of tidal volume, respiratory rate, and supplemental oxygen flow on delivered oxygen fraction using a mouth to mask ventilation device.
Palmisano JM; Moler FW; Galura C; Gordon M; Custer JR
J Emerg Med; 1993; 11(6):685-9. PubMed ID: 8157905
[TBL] [Abstract][Full Text] [Related]
66. Higher Fresh Gas Flow Rates Decrease Tidal Volume During Pressure Control Ventilation.
Mohammad S; Gravenstein N; Gonsalves D; Vasilopoulos T; Lampotang S
Anesth Analg; 2017 May; 124(5):1506-1511. PubMed ID: 28333703
[TBL] [Abstract][Full Text] [Related]
67. Measurement of oxygen concentration delivered via nasal cannulae by tracheal sampling.
O'Reilly Nugent A; Kelly PT; Stanton J; Swanney MP; Graham B; Beckert L
Respirology; 2014 May; 19(4):538-43. PubMed ID: 24661379
[TBL] [Abstract][Full Text] [Related]
68. [Experimental study of changes in FiO2 during manual ventilation].
Diependaele JF; Rakza T; Truffert P; Abazine A; Riou Y; Goldstein P; Lequien P; Storme L
Arch Pediatr; 2001 Apr; 8(4):368-73. PubMed ID: 11339127
[TBL] [Abstract][Full Text] [Related]
69. Oxygen delivery using neonatal self-inflating resuscitation bags without a reservoir.
Thió M; Bhatia R; Dawson JA; Davis PG
Arch Dis Child Fetal Neonatal Ed; 2010 Sep; 95(5):F315-9. PubMed ID: 19843501
[TBL] [Abstract][Full Text] [Related]
70. In Vitro-In Silico Comparison of Pulsed Oxygen Delivery From Portable Oxygen Concentrators Versus Continuous Flow Oxygen Delivery.
Chen JZ; Katz IM; Pichelin M; Zhu K; Caillibotte G; Finlay WH; Martin AR
Respir Care; 2019 Feb; 64(2):117-129. PubMed ID: 30696754
[TBL] [Abstract][Full Text] [Related]
71. Maximum FIO2 in minimum time depending on the kind of resuscitation bag and oxygen flow.
Quintana S; Martínez Pérez J; Alvarez M; Vila JS; Jara F; Nava JM
Intensive Care Med; 2004 Jan; 30(1):155-8. PubMed ID: 14551682
[TBL] [Abstract][Full Text] [Related]
72. Malfunction of the Siaretron 1000 Iper™ hyperbaric ventilator.
Bothma PA; Brodbeck A; Bapat U
Diving Hyperb Med; 2009 Mar; 39(1):45-7. PubMed ID: 22753168
[TBL] [Abstract][Full Text] [Related]
73. Performance characteristics of seven bilevel mechanical ventilators in pressure-support mode with different cycling criteria: a comparative bench study.
Chen Y; Cheng K; Zhou X
Med Sci Monit; 2015 Jan; 21():310-7. PubMed ID: 25619202
[TBL] [Abstract][Full Text] [Related]
74. Evaluation of a Rebreathing System for Use with Portable Mechanical Ventilators.
Blakeman T; Smith M; Branson R
J Spec Oper Med; 2024 Jun; 24(2):34-38. PubMed ID: 38837173
[TBL] [Abstract][Full Text] [Related]
75. Perioperative pulmonary function in acute respiratory failure: effect of ventilator type and gas mixture.
Schapera A; Marks JD; Minagi H; Goodman P; Katz JA
Anesthesiology; 1989 Sep; 71(3):396-402. PubMed ID: 2774267
[TBL] [Abstract][Full Text] [Related]
76. Evaluation of a portable, lightweight modular system to deliver high inspired oxygen to trauma casualties without the use of pressurised cylinders.
Kirkman E; Pope C; Wilson C; Woolley T; Watts S; Byers M
BMJ Mil Health; 2024 Jun; ():. PubMed ID: 38909997
[TBL] [Abstract][Full Text] [Related]
77. [Laboratory testing measurement of FIO2 delivered by Boussignac CPAP system with an input of 100% oxygen].
Templier F; Dolveck F; Baer M; Chauvin M; Fletcher D
Ann Fr Anesth Reanim; 2003 Feb; 22(2):103-7. PubMed ID: 12706763
[TBL] [Abstract][Full Text] [Related]
78. Positive end expiratory pressure and critical oxygenation during transport in ventilated patients.
McQuillan PJ; Hillman DR; Woods WP
Intensive Care Med; 1990; 16(8):513-6. PubMed ID: 2286733
[TBL] [Abstract][Full Text] [Related]
79. Comparison of three high flow oxygen therapy delivery devices: a clinical physiological cross-over study.
Chanques G; Riboulet F; Molinari N; Carr J; Jung B; Prades A; Galia F; Futier E; Constantin JM; Jaber S
Minerva Anestesiol; 2013 Dec; 79(12):1344-55. PubMed ID: 23857440
[TBL] [Abstract][Full Text] [Related]
80. Performance of portable ventilators at altitude.
Blakeman T; Britton T; Rodriquez D; Branson R
J Trauma Acute Care Surg; 2014 Sep; 77(3 Suppl 2):S151-5. PubMed ID: 25159349
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]