517 related articles for article (PubMed ID: 20623672)
1. Collagen/heparin coating on titanium surface improves the biocompatibility of titanium applied as a blood-contacting biomaterial.
Chen J; Chen C; Chen Z; Chen J; Li Q; Huang N
J Biomed Mater Res A; 2010 Nov; 95(2):341-9. PubMed ID: 20623672
[TBL] [Abstract][Full Text] [Related]
2. Heparin/collagen multilayer as a thromboresistant and endothelial favorable coating for intravascular stent.
Lin Q; Yan J; Qiu F; Song X; Fu G; Ji J
J Biomed Mater Res A; 2011 Jan; 96(1):132-41. PubMed ID: 21105161
[TBL] [Abstract][Full Text] [Related]
3. The effect of coimmobilizing heparin and fibronectin on titanium on hemocompatibility and endothelialization.
Li G; Yang P; Qin W; Maitz MF; Zhou S; Huang N
Biomaterials; 2011 Jul; 32(21):4691-703. PubMed ID: 21463893
[TBL] [Abstract][Full Text] [Related]
4. Influence of a layer-by-layer-assembled multilayer of anti-CD34 antibody, vascular endothelial growth factor, and heparin on the endothelialization and anticoagulation of titanium surface.
Liu S; Liu T; Chen J; Maitz M; Chen C; Huang N
J Biomed Mater Res A; 2013 Apr; 101(4):1144-57. PubMed ID: 23045161
[TBL] [Abstract][Full Text] [Related]
5. Anticoagulant surface modification of titanium via layer-by-layer assembly of collagen and sulfated chitosan multilayers.
Li QL; Huang N; Chen J; Wan G; Zhao A; Chen J; Wang J; Yang P; Leng Y
J Biomed Mater Res A; 2009 Jun; 89(3):575-84. PubMed ID: 18435411
[TBL] [Abstract][Full Text] [Related]
6. Biofunctionalization of titanium with PEG and anti-CD34 for hemocompatibility and stimulated endothelialization.
Chen J; Cao J; Wang J; Maitz MF; Guo L; Zhao Y; Li Q; Xiong K; Huang N
J Colloid Interface Sci; 2012 Feb; 368(1):636-47. PubMed ID: 22172691
[TBL] [Abstract][Full Text] [Related]
7. Polysaccharide-protein surface modification of titanium via a layer-by-layer technique: characterization and cell behaviour aspects.
Cai K; Rechtenbach A; Hao J; Bossert J; Jandt KD
Biomaterials; 2005 Oct; 26(30):5960-71. PubMed ID: 15913761
[TBL] [Abstract][Full Text] [Related]
8. The endothelialization and hemocompatibility of the functional multilayer on titanium surface constructed with type IV collagen and heparin.
Zhang K; Li JA; Deng K; Liu T; Chen JY; Huang N
Colloids Surf B Biointerfaces; 2013 Aug; 108():295-304. PubMed ID: 23563297
[TBL] [Abstract][Full Text] [Related]
9. The covalent immobilization of heparin to pulsed-plasma polymeric allylamine films on 316L stainless steel and the resulting effects on hemocompatibility.
Yang Z; Wang J; Luo R; Maitz MF; Jing F; Sun H; Huang N
Biomaterials; 2010 Mar; 31(8):2072-83. PubMed ID: 20022107
[TBL] [Abstract][Full Text] [Related]
10. In situ endothelialization of intravascular stents coated with an anti-CD34 antibody functionalized heparin-collagen multilayer.
Lin Q; Ding X; Qiu F; Song X; Fu G; Ji J
Biomaterials; 2010 May; 31(14):4017-25. PubMed ID: 20149438
[TBL] [Abstract][Full Text] [Related]
11. Anticoagulation and endothelial cell behaviors of heparin-loaded graphene oxide coating on titanium surface.
Pan CJ; Pang LQ; Gao F; Wang YN; Liu T; Ye W; Hou YH
Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():333-40. PubMed ID: 27040227
[TBL] [Abstract][Full Text] [Related]
12. Response of fibroblast activity and polyelectrolyte multilayer films coating titanium.
Brunot C; Grosgogeat B; Picart C; Lagneau C; Jaffrezic-Renault N; Ponsonnet L
Dent Mater; 2008 Aug; 24(8):1025-35. PubMed ID: 18237774
[TBL] [Abstract][Full Text] [Related]
13. The response of osteoblast-like cells towards collagen type I coating immobilized by p-nitrophenylchloroformate to titanium.
van den Dolder J; Jansen JA
J Biomed Mater Res A; 2007 Dec; 83(3):712-9. PubMed ID: 17559125
[TBL] [Abstract][Full Text] [Related]
14. Oriented immobilization of anti-CD34 antibody on titanium surface for self-endothelialization induction.
Li QL; Huang N; Chen C; Chen JL; Xiong KQ; Chen JY; You TX; Jin J; Liang X
J Biomed Mater Res A; 2010 Sep; 94(4):1283-93. PubMed ID: 20694996
[TBL] [Abstract][Full Text] [Related]
15. Plasma mediated collagen-I-coating of metal implant materials to improve biocompatibility.
Hauser J; Koeller M; Bensch S; Halfmann H; Awakowicz P; Steinau HU; Esenwein S
J Biomed Mater Res A; 2010 Jul; 94(1):19-26. PubMed ID: 20091709
[TBL] [Abstract][Full Text] [Related]
16. Biofunctionalization of titanium surface with multilayer films modified by heparin-VEGF-fibronectin complex to improve endothelial cell proliferation and blood compatibility.
Wang HG; Yin TY; Ge SP; Zhang Q; Dong QL; Lei DX; Sun DM; Wang GX
J Biomed Mater Res A; 2013 Feb; 101(2):413-20. PubMed ID: 22865832
[TBL] [Abstract][Full Text] [Related]
17. Heparin-mimicking multilayer coating on polymeric membrane via LbL assembly of cyclodextrin-based supramolecules.
Deng J; Liu X; Ma L; Cheng C; Shi W; Nie C; Zhao C
ACS Appl Mater Interfaces; 2014 Dec; 6(23):21603-14. PubMed ID: 25375347
[TBL] [Abstract][Full Text] [Related]
18. Tailoring of the titanium surface by immobilization of heparin/fibronectin complexes for improving blood compatibility and endothelialization: an in vitro study.
Li G; Yang P; Liao Y; Huang N
Biomacromolecules; 2011 Apr; 12(4):1155-68. PubMed ID: 21332186
[TBL] [Abstract][Full Text] [Related]
19. Surface engineering of titanium thin films with silk fibroin via layer-by-layer technique and its effects on osteoblast growth behavior.
Cai K; Hu Y; Jandt KD
J Biomed Mater Res A; 2007 Sep; 82(4):927-35. PubMed ID: 17335030
[TBL] [Abstract][Full Text] [Related]
20. Immobilization of heparin/poly-(L)-lysine nanoparticles on dopamine-coated surface to create a heparin density gradient for selective direction of platelet and vascular cells behavior.
Liu T; Liu Y; Chen Y; Liu S; Maitz MF; Wang X; Zhang K; Wang J; Wang Y; Chen J; Huang N
Acta Biomater; 2014 May; 10(5):1940-54. PubMed ID: 24342042
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]