These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 20628818)

  • 1. Estimation of the bidomain conductivity parameters of cardiac tissue from extracellular potential distributions initiated by point stimulation.
    Graham LS; Kilpatrick D
    Ann Biomed Eng; 2010 Dec; 38(12):3630-48. PubMed ID: 20628818
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Estimation of cardiac bidomain parameters from extracellular measurement: two dimensional study.
    Sadleir R; Henriquez C
    Ann Biomed Eng; 2006 Aug; 34(8):1289-303. PubMed ID: 16804743
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of conductivity values on ST segment shift in subendocardial ischaemia.
    Johnston PR; Kilpatrick D
    IEEE Trans Biomed Eng; 2003 Feb; 50(2):150-8. PubMed ID: 12665028
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A sensitivity study of conductivity values in the passive bidomain equation.
    Johnston PR
    Math Biosci; 2011 Aug; 232(2):142-50. PubMed ID: 21624377
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The use of spectral methods in bidomain studies.
    Trayanova N; Pilkington T
    Crit Rev Biomed Eng; 1992; 20(3-4):255-77. PubMed ID: 1478093
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A bidomain model with periodic intracellular junctions: a one-dimensional analysis.
    Trayanova N; Pilkington TC
    IEEE Trans Biomed Eng; 1993 May; 40(5):424-33. PubMed ID: 8225331
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Forward Euler stability of the bidomain model of cardiac tissue.
    Puwal S; Roth BJ
    IEEE Trans Biomed Eng; 2007 May; 54(5):951-3. PubMed ID: 17518295
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of electrode configurations for measuring cardiac tissue conductivities and fibre rotation.
    Johnston BM; Johnston PR; Kilpatrick D
    Ann Biomed Eng; 2006 Jun; 34(6):986-96. PubMed ID: 16783654
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determining six cardiac conductivities from realistically large datasets.
    Johnston BM; Johnston PR
    Math Biosci; 2015 Aug; 266():15-22. PubMed ID: 26048188
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new approach to the determination of cardiac potential distributions: application to the analysis of electrode configurations.
    Johnston BM; Johnston PR; Kilpatrick D
    Math Biosci; 2006 Aug; 202(2):288-309. PubMed ID: 16797036
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Deriving macroscopic myocardial conductivities by homogenization of microscopic models.
    Hand PE; Griffith BE; Peskin CS
    Bull Math Biol; 2009 Oct; 71(7):1707-26. PubMed ID: 19412638
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Six Conductivity Values to Use in the Bidomain Model of Cardiac Tissue.
    Johnston BM
    IEEE Trans Biomed Eng; 2016 Jul; 63(7):1525-31. PubMed ID: 26560866
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A solution method for the determination of cardiac potential distributions with an alternating current source.
    Johnston BM; Johnston PR; Kilpatrick D
    Comput Methods Biomech Biomed Engin; 2008 Jun; 11(3):223-33. PubMed ID: 18568820
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Construction and validation of a plunge electrode array for three-dimensional determination of conductivity in the heart.
    Hooks DA; Trew ML
    IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):626-35. PubMed ID: 18269998
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrical conductivity values used with the bidomain model of cardiac tissue.
    Roth BJ
    IEEE Trans Biomed Eng; 1997 Apr; 44(4):326-8. PubMed ID: 9125816
    [TBL] [Abstract][Full Text] [Related]  

  • 16. How electrode size affects the electric potential distribution in cardiac tissue.
    Patel SG; Roth BJ
    IEEE Trans Biomed Eng; 2000 Sep; 47(9):1284-7. PubMed ID: 11008431
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Exploring anodal and cathodal make and break cardiac excitation mechanisms in a 3D anisotropic bidomain model.
    Colli-Franzone P; Pavarino LF; Scacchi S
    Math Biosci; 2011 Apr; 230(2):96-114. PubMed ID: 21329705
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Using a sensitivity study to facilitate the design of a multi-electrode array to measure six cardiac conductivity values.
    Johnston BM
    Math Biosci; 2013 Jul; 244(1):40-6. PubMed ID: 23624254
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Extracellular measurement of anisotropic bidomain myocardial conductivities. I. Theoretical analysis.
    Le Guyader P; Trelles F; Savard P
    Ann Biomed Eng; 2001 Oct; 29(10):862-77. PubMed ID: 11764317
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Current injection into a two-dimensional anisotropic bidomain.
    Sepulveda NG; Roth BJ; Wikswo JP
    Biophys J; 1989 May; 55(5):987-99. PubMed ID: 2720084
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.