104 related articles for article (PubMed ID: 20630337)
1. Determination of accurate stent graft configuration in abdominal aortic aneurysm using computed tomography: a preliminary study.
Kim HC; Park SW; Nam KW; Choi H; Choi EJ; Jin S; Kim MG; Sun K
Clin Imaging; 2010; 34(4):255-62. PubMed ID: 20630337
[TBL] [Abstract][Full Text] [Related]
2. Assessment of abdominal aortic aneurysms using a cone-beam CT system: an experimental phantom study and an initial clinical evaluation before and after stent-graft treatment in patients with an abdominal aortic aneurysm.
Ichikawa K; Kumazaki T; Hayashi H; Ochi M
J Nippon Med Sch; 2001 Dec; 68(6):498-509. PubMed ID: 11744930
[TBL] [Abstract][Full Text] [Related]
3. Comparison of the deployment and healing of thin-walled expanded PTFE stented grafts and covered stents.
White R; Kopchok G; Zalewski M; Ayres B; Wilson E; de Virgilio C; Donayre C
Ann Vasc Surg; 1996 Jul; 10(4):336-46. PubMed ID: 8879388
[TBL] [Abstract][Full Text] [Related]
4. Helical CT angiography of stent-grafts in abdominal aortic aneurysms: morphologic changes and complications.
Tillich M; Hausegger KA; Tiesenhausen K; Tauss J; Groell R; Szolar DH
Radiographics; 1999; 19(6):1573-83. PubMed ID: 10555675
[TBL] [Abstract][Full Text] [Related]
5. Pulsatile distension of the proximal aneurysm neck is larger in patients with stent graft migration.
van Keulen JW; Moll FL; Barwegen GK; Vonken EP; van Herwaarden JA
Eur J Vasc Endovasc Surg; 2010 Sep; 40(3):326-31. PubMed ID: 20561803
[TBL] [Abstract][Full Text] [Related]
6. The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation device.
Litwinski RA; Donayre CE; Chow SL; Song TK; Kopchok G; Walot I; White RA
J Vasc Surg; 2006 Dec; 44(6):1176-81. PubMed ID: 17145418
[TBL] [Abstract][Full Text] [Related]
7. Localization and segmentation of aortic endografts using marker detection.
de Bruijne M; Niessen WJ; Maintz JB; Viergever MA
IEEE Trans Med Imaging; 2003 Apr; 22(4):473-82. PubMed ID: 12774893
[TBL] [Abstract][Full Text] [Related]
8. CT virtual intravascular endoscopy in the visualization of fenestrated stent-grafts.
Sun Z; Allen YB; Nadkarni S; Knight R; Hartley DE; Lawrence-Brown MM
J Endovasc Ther; 2008 Feb; 15(1):42-51. PubMed ID: 18254667
[TBL] [Abstract][Full Text] [Related]
9. The influence of different types of stent grafts on aneurysm neck dynamics after endovascular aneurysm repair.
van Keulen JW; Vincken KL; van Prehn J; Tolenaar JL; Bartels LW; Viergever MA; Moll FL; van Herwaarden JA
Eur J Vasc Endovasc Surg; 2010 Feb; 39(2):193-9. PubMed ID: 19879781
[TBL] [Abstract][Full Text] [Related]
10. A quantitative evaluation of abdominal aorta aneurysm by CT images.
Park CS; Park JI; Kim KG; Cho CN; Ahn BU; Jae HJ
Technol Health Care; 2015; 23(1):37-45. PubMed ID: 25408283
[TBL] [Abstract][Full Text] [Related]
11. Automatic detection of selective arterial devices for advanced visualization during abdominal aortic aneurysm endovascular repair.
Lessard S; Kauffmann C; Pfister M; Cloutier G; Thérasse É; de Guise JA; Soulez G
Med Eng Phys; 2015 Oct; 37(10):979-86. PubMed ID: 26362721
[TBL] [Abstract][Full Text] [Related]
12. Computational fluid dynamics: hemodynamic changes in abdominal aortic aneurysm after stent-graft implantation.
Frauenfelder T; Lotfey M; Boehm T; Wildermuth S
Cardiovasc Intervent Radiol; 2006; 29(4):613-23. PubMed ID: 16508795
[TBL] [Abstract][Full Text] [Related]
13. Computed tomography virtual intravascular endoscopy in the evaluation of fenestrated stent graft repair of abdominal aortic aneurysms.
Sun Z; Mwipatayi BP; Allen YB; Hartley DE; Lawrence-Brown MM
ANZ J Surg; 2009 Nov; 79(11):836-40. PubMed ID: 20078536
[TBL] [Abstract][Full Text] [Related]
14. Measurement of abdominal aortic aneurysms with three-dimensional ultrasound imaging: preliminary report.
Leotta DF; Paun M; Beach KW; Kohler TR; Zierler RE; Strandness DE
J Vasc Surg; 2001 Apr; 33(4):700-7. PubMed ID: 11296320
[TBL] [Abstract][Full Text] [Related]
15. Durability of abdominal aortic endograft with the Talent Unidoc stent graft in common practice: Core lab reanalysis from the TAURIS multicenter study.
Cao P; De Rango P; Parlani G; Verzini F;
J Vasc Surg; 2009 Apr; 49(4):859-65. PubMed ID: 19341881
[TBL] [Abstract][Full Text] [Related]
16. Three-dimensional visualization of suprarenal aortic stent-grafts: evaluation of migration in midterm follow-up.
Sun Z
J Endovasc Ther; 2006 Feb; 13(1):85-93. PubMed ID: 16445328
[TBL] [Abstract][Full Text] [Related]
17. The Anaconda AAA stent graft system: 2-year clinical and technical results of a multicentre clinical evaluation.
Rödel SG; Geelkerken RH; Prescott RJ; Florek HJ; Kasprzak P; Brunkwall J;
Eur J Vasc Endovasc Surg; 2009 Dec; 38(6):732-40. PubMed ID: 19775918
[TBL] [Abstract][Full Text] [Related]
18. [Influence of fixation mechanism on changes of the supra- and infrarenal segment of the aorta after endovascular treatment of infrarenal aortic aneurysm].
Oberhuber A; Schwarz A; Hoffmann M; Klass O; Schelzig H; Orend KH; Mühling B
Zentralbl Chir; 2010 Oct; 135(5):433-7. PubMed ID: 20976646
[TBL] [Abstract][Full Text] [Related]
19. Three dimensional active contours for the reconstruction of abdominal aortic aneurysms.
Ayyalasomayajula A; Polk A; Basudhar A; Missoum S; Nissim L; Vande Geest JP
Ann Biomed Eng; 2010 Jan; 38(1):164-76. PubMed ID: 19902358
[TBL] [Abstract][Full Text] [Related]
20. Endovascular treatment of abdominal aortic aneurysms--6 years of experience with Ella stent-graft system.
Köcher M; Utíkal P; Koutná J; Bachleda P; Buriánková E; Herman M; Bucil J; Benýsek V; Cerná M; Kojecký Z
Eur J Radiol; 2004 Aug; 51(2):181-8. PubMed ID: 15246525
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]