212 related articles for article (PubMed ID: 20636059)
1. Miniature mass spectrometers.
Ouyang Z; Cooks RG
Annu Rev Anal Chem (Palo Alto Calif); 2009; 2():187-214. PubMed ID: 20636059
[TBL] [Abstract][Full Text] [Related]
2. Sampling wand for an ion trap mass spectrometer.
Hou K; Xu W; Xu J; Cooks RG; Ouyang Z
Anal Chem; 2011 Mar; 83(5):1857-61. PubMed ID: 21299234
[TBL] [Abstract][Full Text] [Related]
3. Synchronized discharge ionization for analysis of volatile organic compounds using a hand-held ion trap mass spectrometer.
Chen TC; Ouyang Z
Anal Chem; 2013 Feb; 85(3):1767-72. PubMed ID: 23256567
[TBL] [Abstract][Full Text] [Related]
4. Design and characterization of a multisource hand-held tandem mass spectrometer.
Gao L; Sugiarto A; Harper JD; Cooks RG; Ouyang Z
Anal Chem; 2008 Oct; 80(19):7198-205. PubMed ID: 18754674
[TBL] [Abstract][Full Text] [Related]
5. Atmospheric pressure ionization in a miniature mass spectrometer.
Laughlin BC; Mulligan CC; Cooks RG
Anal Chem; 2005 May; 77(9):2928-39. PubMed ID: 15859613
[TBL] [Abstract][Full Text] [Related]
6. Breaking the pumping speed barrier in mass spectrometry: discontinuous atmospheric pressure interface.
Gao L; Cooks RG; Ouyang Z
Anal Chem; 2008 Jun; 80(11):4026-32. PubMed ID: 18461971
[TBL] [Abstract][Full Text] [Related]
7. Development of a miniature mass spectrometer with continuous atmospheric pressure interface.
Zhai Y; Feng Y; Wei Y; Wang Y; Xu W
Analyst; 2015 May; 140(10):3406-14. PubMed ID: 25860539
[TBL] [Abstract][Full Text] [Related]
8. Miniature mass analyzers.
Badman ER; Graham Cooks R
J Mass Spectrom; 2000 Jun; 35(6):659-71. PubMed ID: 10862117
[TBL] [Abstract][Full Text] [Related]
9. Miniaturization and geometry optimization of a polymer-based rectilinear ion trap.
Fico M; Yu M; Ouyang Z; Cooks RG; Chappell WJ
Anal Chem; 2007 Nov; 79(21):8076-82. PubMed ID: 17914891
[TBL] [Abstract][Full Text] [Related]
10. High-throughput miniature cylindrical ion trap array mass spectrometer.
Tabert AM; Griep-Raming J; Guymon AJ; Cooks RG
Anal Chem; 2003 Nov; 75(21):5656-64. PubMed ID: 14588002
[TBL] [Abstract][Full Text] [Related]
11. Ambient ionization and miniature mass spectrometry system for chemical and biological analysis.
Ma X; Ouyang Z
Trends Analyt Chem; 2016 Dec; 85(A):10-19. PubMed ID: 28042191
[TBL] [Abstract][Full Text] [Related]
12. Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector.
Amsden JJ; Herr PJ; Landry DMW; Kim W; Vyas R; Parker CB; Kirley MP; Keil AD; Gilchrist KH; Radauscher EJ; Hall SD; Carlson JB; Baldasaro N; Stokes D; Di Dona ST; Russell ZE; Grego S; Edwards SJ; Sperline RP; Denton MB; Stoner BR; Gehm ME; Glass JT
J Am Soc Mass Spectrom; 2018 Feb; 29(2):360-372. PubMed ID: 29052038
[TBL] [Abstract][Full Text] [Related]
13. Ambient mass spectrometry with a handheld mass spectrometer at high pressure.
Keil A; Talaty N; Janfelt C; Noll RJ; Gao L; Ouyang Z; Cooks RG
Anal Chem; 2007 Oct; 79(20):7734-9. PubMed ID: 17867653
[TBL] [Abstract][Full Text] [Related]
14. High-Throughput Screening Using a Synchronized Pulsed Self-aspiration Vacuum Electrospray Ionization Miniature Mass Spectrometer.
Zhu Y; Zhang Q; Zhang Q; Lu J; Wang K; Zhang R; Yu Q
Anal Chem; 2022 May; 94(20):7417-7424. PubMed ID: 35533348
[TBL] [Abstract][Full Text] [Related]
15. Handheld rectilinear ion trap mass spectrometer.
Gao L; Song Q; Patterson GE; Cooks RG; Ouyang Z
Anal Chem; 2006 Sep; 78(17):5994-6002. PubMed ID: 16944876
[TBL] [Abstract][Full Text] [Related]
16. Autonomous in situ analysis and real-time chemical detection using a backpack miniature mass spectrometer: concept, instrumentation development, and performance.
Hendricks PI; Dalgleish JK; Shelley JT; Kirleis MA; McNicholas MT; Li L; Chen TC; Chen CH; Duncan JS; Boudreau F; Noll RJ; Denton JP; Roach TA; Ouyang Z; Cooks RG
Anal Chem; 2014 Mar; 86(6):2900-8. PubMed ID: 24521448
[TBL] [Abstract][Full Text] [Related]
17. Mini 12, miniature mass spectrometer for clinical and other applications--introduction and characterization.
Li L; Chen TC; Ren Y; Hendricks PI; Cooks RG; Ouyang Z
Anal Chem; 2014 Mar; 86(6):2909-16. PubMed ID: 24521423
[TBL] [Abstract][Full Text] [Related]
18. Development of a low power miniature linear ion trap mass spectrometer with extended mass range.
Li G; Li D; Cheng Y; Pei X; Zhang H; Wang Y; Sun J; Dong M
Rev Sci Instrum; 2017 Dec; 88(12):123108. PubMed ID: 29289174
[TBL] [Abstract][Full Text] [Related]
19. Glow discharge electron impact ionization source for miniature mass spectrometers.
Gao L; Song Q; Noll RJ; Duncan J; Cooks RG; Ouyang Z
J Mass Spectrom; 2007 May; 42(5):675-80. PubMed ID: 17441220
[TBL] [Abstract][Full Text] [Related]
20. Characterization of electrode surface roughness and its impact on ion trap mass analysis.
Xu W; Chappell WJ; Cooks RG; Ouyang Z
J Mass Spectrom; 2009 Mar; 44(3):353-60. PubMed ID: 19021150
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]