108 related articles for article (PubMed ID: 20640991)
1. Heat generation during cement removal in revision total hip replacement - a comparison of three methods.
Nogler M; Mayr E
Hip Int; 2010; 20(3):308-13. PubMed ID: 20640991
[TBL] [Abstract][Full Text] [Related]
2. Excessive heat generation during cutting of cement in the Robodoc hip-revision procedure.
Nogler M; Krismer M; Haid C; Ogon M; Bach C; Wimmer C
Acta Orthop Scand; 2001 Dec; 72(6):595-9. PubMed ID: 11817874
[TBL] [Abstract][Full Text] [Related]
3. Contamination during removal of cement in revision hip arthroplasty. A cadaver study using ultrasound and high-speed cutters.
Nogler M; Lass-Flörl C; Wimmer C; Mayr E; Bach C; Ogon M
J Bone Joint Surg Br; 2003 Apr; 85(3):436-9. PubMed ID: 12729125
[TBL] [Abstract][Full Text] [Related]
4. Thermal tissue damage caused by ultrasonic cement removal from the humerus.
Goldberg SH; Cohen MS; Young M; Bradnock B
J Bone Joint Surg Am; 2005 Mar; 87(3):583-91. PubMed ID: 15741626
[TBL] [Abstract][Full Text] [Related]
5. Effect of an ultrasonic device on temperatures generated in bone and on bone-cement structure.
Brooks AT; Nelson CL; Stewart CL; Skinner RA; Siems ML
J Arthroplasty; 1993 Aug; 8(4):413-8. PubMed ID: 8409994
[TBL] [Abstract][Full Text] [Related]
6. A-mode ultrasound-based intra-femoral bone cement detection and 3D reconstruction in RTHR.
Heger S; Mumme T; Sellei R; De La Fuente M; Wirtz DC; Radermacher K
Comput Aided Surg; 2007 May; 12(3):168-75. PubMed ID: 17538789
[TBL] [Abstract][Full Text] [Related]
7. Histological findings of the femoral bone after cement removal in hip revision. An experimental study of cadaver femurs with two different cement removal procedures.
Porsch M; Schmidt J
Arch Orthop Trauma Surg; 2003 Jun; 123(5):199-202. PubMed ID: 12743715
[TBL] [Abstract][Full Text] [Related]
8. Comparison of Ho:YAG laser and coblation for interface tissue removal in minimally invasive hip refixation procedures.
Kraaij G; Malan DF; van der Heide HJ; Dankelman J; Nelissen RG; Valstar ER
Med Eng Phys; 2012 Apr; 34(3):370-7. PubMed ID: 21855390
[TBL] [Abstract][Full Text] [Related]
9. Femoral cement extraction in revision total hip arthroplasty--an in vitro study comparing computer-assisted freehand-navigated cement removal to conventional cement extraction.
Mumme T; Friedrich MJ; Rode H; Gravius S; Andereya S; Müller-Rath R; de la Fuente M
Biomed Tech (Berl); 2015 Dec; 60(6):567-75. PubMed ID: 26053005
[TBL] [Abstract][Full Text] [Related]
10. Comparison of fixation of the femoral component without cement and fixation with use of a bone-vacuum cementing technique for the prevention of fat embolism during total hip arthroplasty. A prospective, randomized clinical trial.
Pitto RP; Koessler M; Kuehle JW
J Bone Joint Surg Am; 1999 Jun; 81(6):831-43. PubMed ID: 10391548
[TBL] [Abstract][Full Text] [Related]
11. Reduction of the potential for thermal damage during hip resurfacing.
Gill HS; Campbell PA; Murray DW; De Smet KA
J Bone Joint Surg Br; 2007 Jan; 89(1):16-20. PubMed ID: 17259409
[TBL] [Abstract][Full Text] [Related]
12. A device for removal of femoral distal cement plug during hip revision arthroplasty: a high-powered drill equipped with a centralizer.
Jingushi S; Noguchi Y; Shuto T; Nakashima T; Iwamoto Y
J Arthroplasty; 2000 Feb; 15(2):231-3. PubMed ID: 10708092
[TBL] [Abstract][Full Text] [Related]
13. Failure of total hip arthroplasty with a precoated prosthesis. 4- to 11-year results.
Dowd JE; Cha CW; Trakru S; Kim SY; Yang IH; Rubash HE
Clin Orthop Relat Res; 1998 Oct; (355):123-36. PubMed ID: 9917597
[TBL] [Abstract][Full Text] [Related]
14. Thermal effects of cement mantle thickness for hip resurfacing.
Little JP; Gray HA; Murray DW; Beard DJ; Gill HS
J Arthroplasty; 2008 Apr; 23(3):454-8. PubMed ID: 18358388
[TBL] [Abstract][Full Text] [Related]
15. Effects of pre-cooling and pre-heating procedures on cement polymerization and thermal osteonecrosis in cemented hip replacements.
Li C; Schmid S; Mason J
Med Eng Phys; 2003 Sep; 25(7):559-64. PubMed ID: 12835068
[TBL] [Abstract][Full Text] [Related]
16. The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement.
Seeger JB; Jaeger S; Bitsch RG; Mohr G; Röhner E; Clarius M
J Bone Joint Surg Am; 2013 Jan; 95(1):48-53. PubMed ID: 23283372
[TBL] [Abstract][Full Text] [Related]
17. [Cement removal with ultrasound in revision or total hip prosthesis].
Schwaller CA; Elke R
Orthopade; 2001 May; 30(5):310-6. PubMed ID: 11417239
[TBL] [Abstract][Full Text] [Related]
18. Computer-assisted fluoroscopic navigation system for removal of distal femoral bone cement in revision total hip arthroplasty.
Akiyama H; Kawanabe K; Goto K; Ohnishi E; Nakamura T
J Arthroplasty; 2007 Apr; 22(3):445-8. PubMed ID: 17400101
[TBL] [Abstract][Full Text] [Related]
19. Cement-implant interface gaps explain the poor results of CMW3 for femoral stem fixation: A cadaver study of migration, fatigue and mantle morphology.
Race A; Miller MA; Clarke MT; Mann KA
Acta Orthop; 2005 Oct; 76(5):679-87. PubMed ID: 16263615
[TBL] [Abstract][Full Text] [Related]
20. Cement removal and bone bed preparation of the femoral medullary canal assisted by flexible endoscope in total hip revision arthroplasty.
Takagi M; Tamaki Y; Kobayashi S; Sasaki K; Takakubo Y; Ishii M
J Orthop Sci; 2009 Nov; 14(6):719-26. PubMed ID: 19997818
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]