BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

314 related articles for article (PubMed ID: 20647101)

  • 1. A comparative computational analysis of the mechanical behavior of two nickel-titanium rotary endodontic instruments.
    Necchi S; Petrini L; Taschieri S; Migliavacca F
    J Endod; 2010 Aug; 36(8):1380-4. PubMed ID: 20647101
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical behaviour of nickel-titanium rotary endodontic instruments in simulated clinical conditions: a computational study.
    Necchi S; Taschieri S; Petrini L; Migliavacca F
    Int Endod J; 2008 Nov; 41(11):939-49. PubMed ID: 19133083
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals.
    Kim HC; Kim HJ; Lee CJ; Kim BM; Park JK; Versluis A
    Int Endod J; 2009 Jul; 42(7):593-602. PubMed ID: 19467053
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of cross-sectional design and dimension on mechanical behavior of nickel-titanium instruments under torsion and bending: a numerical analysis.
    Zhang EW; Cheung GS; Zheng YF
    J Endod; 2010 Aug; 36(8):1394-8. PubMed ID: 20647104
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture.
    Kim HC; Lee MH; Yum J; Versluis A; Lee CJ; Kim BM
    J Endod; 2010 Jul; 36(7):1195-9. PubMed ID: 20630298
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile.
    Berutti E; Chiandussi G; Gaviglio I; Ibba A
    J Endod; 2003 Jan; 29(1):15-9. PubMed ID: 12540212
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Instrument separation analysis of multi-used ProTaper Universal rotary system during root canal therapy.
    Wu J; Lei G; Yan M; Yu Y; Yu J; Zhang G
    J Endod; 2011 Jun; 37(6):758-63. PubMed ID: 21787484
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stress distribution of three NiTi rotary files under bending and torsional conditions using a mathematic analysis.
    Kim TO; Cheung GS; Lee JM; Kim BM; Hur B; Kim HC
    Int Endod J; 2009 Jan; 42(1):14-21. PubMed ID: 19125976
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments.
    Miyai K; Ebihara A; Hayashi Y; Doi H; Suda H; Yoneyama T
    Int Endod J; 2006 Feb; 39(2):119-26. PubMed ID: 16454792
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Defects in nickel-titanium instruments after clinical use. Part 5: single use from endodontic specialty practices.
    Shen Y; Coil JM; McLean AG; Hemerling DL; Haapasalo M
    J Endod; 2009 Oct; 35(10):1363-7. PubMed ID: 19801231
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Torque during canal instrumentation using rotary nickel-titanium files.
    Sattapan B; Palamara JE; Messer HH
    J Endod; 2000 Mar; 26(3):156-60. PubMed ID: 11199710
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effectiveness of two nickel-titanium rotary instruments and a hand file for removing gutta-percha in severely curved root canals during retreatment: an ex vivo study.
    Gergi R; Sabbagh C
    Int Endod J; 2007 Jul; 40(7):532-7. PubMed ID: 17511787
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: value of the safety quotient.
    Blum JY; Machtou P; Ruddle C; Micallef JP
    J Endod; 2003 Sep; 29(9):567-75. PubMed ID: 14503829
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation between experimental cyclic fatigue resistance and numerical stress analysis for nickel-titanium rotary files.
    Lee MH; Versluis A; Kim BM; Lee CJ; Hur B; Kim HC
    J Endod; 2011 Aug; 37(8):1152-7. PubMed ID: 21763912
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative analysis of torsional and bending behavior through finite-element models of 5 Ni-Ti endodontic instruments.
    Arbab-Chirani R; Chevalier V; Arbab-Chirani S; Calloch S
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Jan; 111(1):115-21. PubMed ID: 21176826
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Torsional strength and toughness of nickel-titanium rotary files.
    Yum J; Cheung GS; Park JK; Hur B; Kim HC
    J Endod; 2011 Mar; 37(3):382-6. PubMed ID: 21329826
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis.
    Kim HC; Cheung GS; Lee CJ; Kim BM; Park JK; Kang SI
    J Endod; 2008 Jun; 34(6):743-7. PubMed ID: 18498904
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of electrochemical polishing on the mechanical properties of K3 nickel-titanium rotary instruments.
    Barbosa FO; Gomes JA; de Araújo MC
    J Endod; 2008 Dec; 34(12):1533-6. PubMed ID: 19026889
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect from cyclic fatigue of nickel-titanium rotary files on torsional resistance.
    Kim JY; Cheung GS; Park SH; Ko DC; Kim JW; Kim HC
    J Endod; 2012 Apr; 38(4):527-30. PubMed ID: 22414843
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cyclic fatigue testing and metallographic analysis of nickel-titanium rotary instruments.
    Pirani C; Cirulli PP; Chersoni S; Micele L; Ruggeri O; Prati C
    J Endod; 2011 Jul; 37(7):1013-6. PubMed ID: 21689562
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.