These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

80 related articles for article (PubMed ID: 20653761)

  • 1. Real time triplane echocardiography in aortic valve stenosis: validation, reliability, and feasibility of a new method for valve area quantification.
    Alunni G; Giorgi M; Sartori C; Garrone P; Conrotto F; D'Amico M; Scacciatella P; Andriani M; Levis M; Marra S
    Echocardiography; 2010 Jul; 27(6):644-50. PubMed ID: 20653761
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Real time triplane echocardiography in the assessment of the functional area of prosthetic aortic valves: reliability and feasibility.
    Alunni G; Garrone P; Giorgi M; Calcagnile C; Sbarra P; Marocco C; Costanza G; Meynet I; Casolati D; Marra S
    Echocardiography; 2012; 29(1):34-41. PubMed ID: 22044699
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real-time three-dimensional echocardiography in aortic stenosis: a novel, simple, and reliable method to improve accuracy in area calculation.
    Gutiérrez-Chico JL; Zamorano JL; Prieto-Moriche E; Hernández-Antolín RA; Bravo-Amaro M; Pérez de Isla L; Sanmartín-Fernández M; Baz-Alonso JA; Iñiguez-Romo A
    Eur Heart J; 2008 May; 29(10):1296-306. PubMed ID: 17989075
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aortic valve stenosis planimetry by means of three-dimensional transesophageal echocardiography in the real clinical setting: feasibility, reliability and systematic deviations.
    Saura D; de la Morena G; Flores-Blanco PJ; Oliva MJ; Caballero L; González-Carrillo J; Espinosa MD; López-Ruiz M; García-Navarro M; Valdés M
    Echocardiography; 2015 Mar; 32(3):508-15. PubMed ID: 25041359
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-dimensional imaging of the left ventricular outflow tract: impact on aortic valve area estimation by the continuity equation.
    Gaspar T; Adawi S; Sachner R; Asmer I; Ganaeem M; Rubinshtein R; Shiran A
    J Am Soc Echocardiogr; 2012 Jul; 25(7):749-57. PubMed ID: 22613774
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Feasibility of using real time "Live 3D" echocardiography to visualize the stenotic aortic valve.
    Suradi H; Byers S; Green-Hess D; Gradus-Pizlo I; Sawada S; Feigenbaum H
    Echocardiography; 2010 Sep; 27(8):1011-20. PubMed ID: 20849488
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improving the accuracy of effective orifice area assessment after transcatheter aortic valve replacement: validation of left ventricular outflow tract diameter and pulsed-wave Doppler location and impact of three-dimensional measurements.
    Khalique OK; Hamid NB; Kodali SK; Nazif TM; Marcoff L; Paradis JM; Williams MR; Vahl TP; George I; Leon MB; Hahn RT
    J Am Soc Echocardiogr; 2015 Nov; 28(11):1283-93. PubMed ID: 26323890
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography.
    Poh KK; Levine RA; Solis J; Shen L; Flaherty M; Kang YJ; Guerrero JL; Hung J
    Eur Heart J; 2008 Oct; 29(20):2526-35. PubMed ID: 18263866
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of accuracy of aortic valve area assessment in aortic stenosis by real time three-dimensional echocardiography in biplane mode versus two-dimensional transthoracic and transesophageal echocardiography.
    Blot-Souletie N; Hébrard A; Acar P; Carrié D; Puel J
    Echocardiography; 2007 Nov; 24(10):1065-72. PubMed ID: 18001360
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging.
    Thavendiranathan P; Liu S; Datta S; Walls M; Nitinunu A; Van Houten T; Tomson NA; Vidmar L; Georgescu B; Wang Y; Srinivasan S; De Michelis N; Raman SV; Ryan T; Vannan MA
    J Am Soc Echocardiogr; 2012 Jan; 25(1):56-65. PubMed ID: 22105057
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aortic root geometry in patients with aortic stenosis assessed by real-time three-dimensional transesophageal echocardiography.
    Wu VC; Kaku K; Takeuchi M; Otani K; Yoshitani H; Tamura M; Abe H; Lin FC; Otsuji Y
    J Am Soc Echocardiogr; 2014 Jan; 27(1):32-41. PubMed ID: 24238752
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Three-dimensional surface area of the aortic valve orifice by three-dimensional echocardiography: clinical validation of a novel index for assessment of aortic stenosis.
    Ge S; Warner JG; Abraham TP; Kon ND; Brooker RF; Nomeir AM; Fowle KM; Burgess P; Kitzman DW
    Am Heart J; 1998 Dec; 136(6):1042-50. PubMed ID: 9842018
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of aortic stenosis by three-dimensional echocardiography: an accurate and novel approach.
    Goland S; Trento A; Iida K; Czer LS; De Robertis M; Naqvi TZ; Tolstrup K; Akima T; Luo H; Siegel RJ
    Heart; 2007 Jul; 93(7):801-7. PubMed ID: 17488766
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of three-dimensional imaging and pressure recovery on echocardiographic evaluation of severe aortic stenosis: a pilot study.
    Stähli BE; Abouelnour A; Nguyen TD; Vecchiati A; Maier W; Lüscher TF; Frauenfelder T; Tanner FC
    Echocardiography; 2014 Sep; 31(8):1006-16. PubMed ID: 24447293
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Differences in aortic valve area measured with CT planimetry and echocardiography (continuity equation) are related to divergent estimates of left ventricular outflow tract area.
    Halpern EJ; Mallya R; Sewell M; Shulman M; Zwas DR
    AJR Am J Roentgenol; 2009 Jun; 192(6):1668-73. PubMed ID: 19457833
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantification of aortic valve stenosis: head-to-head comparison of 64-slice spiral computed tomography with transesophageal and transthoracic echocardiography and cardiac catheterization.
    Lembcke A; Kivelitz DE; Borges AC; Lachnitt A; Hein PA; Dohmen PM; Thiele H
    Invest Radiol; 2009 Jan; 44(1):7-14. PubMed ID: 19060789
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Precision of forty slice spiral computed tomography for quantifying aortic valve stenosis: comparison with echocardiography and validation against cardiac catheterization.
    Lembcke A; Thiele H; Lachnitt A; Enzweiler CN; Wagner M; Hein PA; Eddicks S; Kivelitz DE
    Invest Radiol; 2008 Oct; 43(10):719-28. PubMed ID: 18791414
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pitfalls of anatomical aortic valve area measurements using two-dimensional transoesophageal echocardiography and the potential of three-dimensional transoesophageal echocardiography.
    Nakai H; Takeuchi M; Yoshitani H; Kaku K; Haruki N; Otsuji Y
    Eur J Echocardiogr; 2010 May; 11(4):369-76. PubMed ID: 20022869
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of dual-source computed tomography for the quantification of the aortic valve area in patients with aortic stenosis versus transthoracic echocardiography and invasive hemodynamic assessment.
    Ropers D; Ropers U; Marwan M; Schepis T; Pflederer T; Wechsel M; Klinghammer L; Flachskampf FA; Daniel WG; Achenbach S
    Am J Cardiol; 2009 Dec; 104(11):1561-7. PubMed ID: 19932793
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real-time 3-dimensional Doppler echocardiography for the assessment of stroke volume: an in vivo human study compared with standard 2-dimensional echocardiography.
    Pemberton J; Li X; Kenny A; Davies CH; Minette MS; Sahn DJ
    J Am Soc Echocardiogr; 2005 Oct; 18(10):1030-6. PubMed ID: 16198879
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.