These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

246 related articles for article (PubMed ID: 20657032)

  • 1. Three-dimensional contrast-enhanced multidetector CT for anatomic, dynamic, and perfusion characterization of abnormal myocardium to guide ventricular tachycardia ablations.
    Tian J; Jeudy J; Smith MF; Jimenez A; Yin X; Bruce PA; Lei P; Turgeman A; Abbo A; Shekhar R; Saba M; Shorofsky S; Dickfeld T
    Circ Arrhythm Electrophysiol; 2010 Oct; 3(5):496-504. PubMed ID: 20657032
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Integration of 3-dimensional scar models from SPECT to guide ventricular tachycardia ablation.
    Tian J; Smith MF; Ahmad G; Dilsizian V; Jimenez A; Dickfeld T
    J Nucl Med; 2012 Jun; 53(6):894-901. PubMed ID: 22577237
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical application of PET/CT fusion imaging for three-dimensional myocardial scar and left ventricular anatomy during ventricular tachycardia ablation.
    Tian J; Smith MF; Chinnadurai P; Dilsizian V; Turgeman A; Abbo A; Gajera K; Xu C; Plotnick D; Peters R; Saba M; Shorofsky S; Dickfeld T
    J Cardiovasc Electrophysiol; 2009 Jun; 20(6):567-604. PubMed ID: 19207761
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Integration of three-dimensional scar maps for ventricular tachycardia ablation with positron emission tomography-computed tomography.
    Dickfeld T; Lei P; Dilsizian V; Jeudy J; Dong J; Voudouris A; Peters R; Saba M; Shekhar R; Shorofsky S
    JACC Cardiovasc Imaging; 2008 Jan; 1(1):73-82. PubMed ID: 19356409
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MRI-Guided ventricular tachycardia ablation: integration of late gadolinium-enhanced 3D scar in patients with implantable cardioverter-defibrillators.
    Dickfeld T; Tian J; Ahmad G; Jimenez A; Turgeman A; Kuk R; Peters M; Saliaris A; Saba M; Shorofsky S; Jeudy J
    Circ Arrhythm Electrophysiol; 2011 Apr; 4(2):172-84. PubMed ID: 21270103
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cardiac CT With Delayed Enhancement in the Characterization of Ventricular Tachycardia Structural Substrate: Relationship Between CT-Segmented Scar and Electro-Anatomic Mapping.
    Esposito A; Palmisano A; Antunes S; Maccabelli G; Colantoni C; Rancoita PMV; Baratto F; Di Serio C; Rizzo G; De Cobelli F; Della Bella P; Del Maschio A
    JACC Cardiovasc Imaging; 2016 Jul; 9(7):822-832. PubMed ID: 26897692
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Relationship of bipolar and unipolar electrogram voltage to scar transmurality and composition derived by magnetic resonance imaging in patients with nonischemic cardiomyopathy undergoing VT ablation.
    Spears DA; Suszko AM; Dalvi R; Crean AM; Ivanov J; Nanthakumar K; Downar E; Chauhan VS
    Heart Rhythm; 2012 Nov; 9(11):1837-46. PubMed ID: 22846338
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Integration of 3D electroanatomic maps and magnetic resonance scar characterization into the navigation system to guide ventricular tachycardia ablation.
    Andreu D; Berruezo A; Ortiz-Pérez JT; Silva E; Mont L; Borràs R; de Caralt TM; Perea RJ; Fernández-Armenta J; Zeljko H; Brugada J
    Circ Arrhythm Electrophysiol; 2011 Oct; 4(5):674-83. PubMed ID: 21880674
    [TBL] [Abstract][Full Text] [Related]  

  • 9. CMR-based identification of critical isthmus sites of ischemic and nonischemic ventricular tachycardia.
    Piers SR; Tao Q; de Riva Silva M; Siebelink HM; Schalij MJ; van der Geest RJ; Zeppenfeld K
    JACC Cardiovasc Imaging; 2014 Aug; 7(8):774-84. PubMed ID: 25051947
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Integration of merged delayed-enhanced magnetic resonance imaging and multidetector computed tomography for the guidance of ventricular tachycardia ablation: a pilot study.
    Cochet H; Komatsu Y; Sacher F; Jadidi AS; Scherr D; Riffaud M; Derval N; Shah A; Roten L; Pascale P; Relan J; Sermesant M; Ayache N; Montaudon M; Laurent F; Hocini M; Haïssaguerre M; Jaïs P
    J Cardiovasc Electrophysiol; 2013 Apr; 24(4):419-26. PubMed ID: 23252727
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hibernating substrate of ventricular tachycardia: a three-dimensional metabolic and electro-anatomic assessment.
    Hussein AA; Niekoop M; Dilsizian V; Ghzally Y; Abdulghani M; Asoglu R; Chen W; Smith M; See V; Shorofsky SR; Dickfeld TM;
    J Interv Card Electrophysiol; 2017 Apr; 48(3):247-254. PubMed ID: 28120237
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Epicardial substrate mapping for ventricular tachycardia ablation in patients with non-ischaemic cardiomyopathy: a new algorithm to differentiate between scar and viable myocardium developed by simultaneous integration of computed tomography and contrast-enhanced magnetic resonance imaging.
    Piers SR; van Huls van Taxis CF; Tao Q; van der Geest RJ; Askar SF; Siebelink HM; Schalij MJ; Zeppenfeld K
    Eur Heart J; 2013 Feb; 34(8):586-96. PubMed ID: 23161702
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Catheter ablation of ventricular tachycardias in patients with ischemic cardiomyopathy: validation of voltage mapping criteria for substrate modification by myocardial viability assessment using FDG PET.
    Kettering K; Weig HJ; Reimold M; Schwegler AC; Busch M; Laszlo R; Gawaz M; Schreieck J
    Clin Res Cardiol; 2010 Nov; 99(11):753-60. PubMed ID: 20532538
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional architecture of scar and conducting channels based on high resolution ce-CMR: insights for ventricular tachycardia ablation.
    Fernández-Armenta J; Berruezo A; Andreu D; Camara O; Silva E; Serra L; Barbarito V; Carotenutto L; Evertz R; Ortiz-Pérez JT; De Caralt TM; Perea RJ; Sitges M; Mont L; Frangi A; Brugada J
    Circ Arrhythm Electrophysiol; 2013 Jun; 6(3):528-37. PubMed ID: 23685537
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of ventricular tachycardia scar substrate by intracardiac echocardiography.
    Hussein A; Jimenez A; Ahmad G; Mesubi O; Klein T; Gurm G; Beck H; Shams O; See V; Saliaris A; Shorofsky S; Dickfeld T
    Pacing Clin Electrophysiol; 2014 Apr; 37(4):412-21. PubMed ID: 24164545
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three-dimensional 123I-meta-iodobenzylguanidine cardiac innervation maps to assess substrate and successful ablation sites for ventricular tachycardia: feasibility study for a novel paradigm of innervation imaging.
    Klein T; Abdulghani M; Smith M; Huang R; Asoglu R; Remo BF; Turgeman A; Mesubi O; Sidhu S; Synowski S; Saliaris A; See V; Shorofsky S; Chen W; Dilsizian V; Dickfeld T
    Circ Arrhythm Electrophysiol; 2015 Jun; 8(3):583-91. PubMed ID: 25713216
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Catheter ablation of ventricular tachycardia guided by contrast-enhanced cardiac computed tomography.
    Bello D; Kipper S; Valderrábano M; Shivkumar K
    Heart Rhythm; 2004 Oct; 1(4):490-2. PubMed ID: 15851204
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Image integration using intracardiac ultrasound and 3D reconstruction for scar mapping and ablation of ventricular tachycardia.
    Bunch TJ; Weiss JP; Crandall BG; Day JD; DiMarco JP; Ferguson JD; Mason PK; McDaniel G; Osborn JS; Wiggins D; Mahapatra S
    J Cardiovasc Electrophysiol; 2010 Jun; 21(6):678-84. PubMed ID: 20102427
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Relation of the unipolar low-voltage penumbra surrounding the endocardial low-voltage scar to ventricular tachycardia circuit sites and ablation outcomes in ischemic cardiomyopathy.
    Chopra N; Tokuda M; Ng J; Reichlin T; Nof E; John RM; Tedrow UB; Stevenson WG
    J Cardiovasc Electrophysiol; 2014 Jun; 25(6):602-8. PubMed ID: 24576211
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Regional myocardial wall thinning at multidetector computed tomography correlates to arrhythmogenic substrate in postinfarction ventricular tachycardia: assessment of structural and electrical substrate.
    Komatsu Y; Cochet H; Jadidi A; Sacher F; Shah A; Derval N; Scherr D; Pascale P; Roten L; Denis A; Ramoul K; Miyazaki S; Daly M; Riffaud M; Sermesant M; Relan J; Ayache N; Kim S; Montaudon M; Laurent F; Hocini M; Haïssaguerre M; Jaïs P
    Circ Arrhythm Electrophysiol; 2013 Apr; 6(2):342-50. PubMed ID: 23476043
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.