These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

525 related articles for article (PubMed ID: 20657873)

  • 1. Comparison of impression techniques and materials for an implant-supported prosthesis.
    Del'Acqua MA; Chávez AM; Amaral AL; Compagnoni MA; Mollo Fde A
    Int J Oral Maxillofac Implants; 2010; 25(4):771-6. PubMed ID: 20657873
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of impression techniques for an implant-supported prosthesis.
    Del'Acqua MA; Chávez AM; Compagnoni MA; Molo Fde A
    Int J Oral Maxillofac Implants; 2010; 25(4):715-21. PubMed ID: 20657866
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of different impression techniques for internal-connection implants.
    Lee YJ; Heo SJ; Koak JY; Kim SK
    Int J Oral Maxillofac Implants; 2009; 24(5):823-30. PubMed ID: 19865622
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions.
    Vigolo P; Majzoub Z; Cordioli G
    J Prosthet Dent; 2003 Feb; 89(2):186-92. PubMed ID: 12616240
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of splinting in accuracy of two implant impression techniques.
    de Avila ED; de Matos Moraes F; Castanharo SM; Del'Acqua MA; de Assis Mollo F
    J Oral Implantol; 2014 Dec; 40(6):633-9. PubMed ID: 25506658
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of impression and pouring techniques for an implant-supported prosthesis.
    Del'Acqua MA; Arioli-Filho JN; Compagnoni MA; Mollo Fde A
    Int J Oral Maxillofac Implants; 2008; 23(2):226-36. PubMed ID: 18548918
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study.
    Lee H; Ercoli C; Funkenbusch PD; Feng C
    J Prosthet Dent; 2008 Feb; 99(2):107-13. PubMed ID: 18262011
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of accuracy of casts of multiple internal connection implant prosthesis obtained from different impression materials and techniques: an in vitro study.
    Pujari M; Garg P; Prithviraj DR
    J Oral Implantol; 2014 Apr; 40(2):137-45. PubMed ID: 24456531
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impression techniques and misfit-induced strains on implant-supported superstructures: an in vitro study.
    Cehreli MC; Akça K
    Int J Periodontics Restorative Dent; 2006 Aug; 26(4):379-85. PubMed ID: 16939020
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of impression techniques for implants. Part 1--Influence of transfer copings surface abrasion.
    Assunção WG; Cardoso A; Gomes EA; Tabata LF; dos Santos PH
    J Prosthodont; 2008 Dec; 17(8):641-7. PubMed ID: 19090889
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster.
    Wise M
    J Prosthet Dent; 2001 Nov; 86(5):532-8. PubMed ID: 11725282
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Master cast accuracy in single-tooth implant replacement cases: an in vitro comparison. A technical note.
    Vigolo P; Fonzi F; Majzoub Z; Cordioli G
    Int J Oral Maxillofac Implants; 2005; 20(3):455-60. PubMed ID: 15973958
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the accuracy of plastic and metal stock trays for implant impressions.
    Del'acqua MA; de Avila ÉD; Amaral ÂL; Pinelli LA; de Assis Mollo F
    Int J Oral Maxillofac Implants; 2012; 27(3):544-50. PubMed ID: 22616047
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models.
    Choi JH; Lim YJ; Yim SH; Kim CW
    Int J Oral Maxillofac Implants; 2007; 22(5):761-8. PubMed ID: 17974110
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An in vitro comparison of the accuracy of implant impressions with coded healing abutments and different implant angulations.
    Al-Abdullah K; Zandparsa R; Finkelman M; Hirayama H
    J Prosthet Dent; 2013 Aug; 110(2):90-100. PubMed ID: 23929370
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A laboratory investigation of the accuracy of two impression techniques for single-tooth implants.
    Daoudi MF; Setchell DJ; Searson LJ
    Int J Prosthodont; 2001; 14(2):152-8. PubMed ID: 11843452
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of different screw-tightening techniques on the strain generated on an internal-connection implant superstructure. Part 2: Models created with a splinted impression technique.
    Choi JH
    Int J Oral Maxillofac Implants; 2011; 26(5):1016-23. PubMed ID: 22010085
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the precision of three implant transfer impression techniques using two elastomeric impression materials.
    Mostafa TM; Elgendy MN; Kashef NA; Halim MM
    Int J Prosthodont; 2010; 23(6):525-8. PubMed ID: 21209987
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of the accuracy of polyether, polyvinyl siloxane, and plaster impressions for long-span implant-supported prostheses.
    Hoods-Moonsammy VJ; Owen P; Howes DG
    Int J Prosthodont; 2014; 27(5):433-8. PubMed ID: 25191885
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparative study of the accuracy between plastic and metal impression transfer copings for implant restorations.
    Fernandez MA; Paez de Mendoza CY; Platt JA; Levon JA; Hovijitra ST; Nimmo A
    J Prosthodont; 2013 Jul; 22(5):367-76. PubMed ID: 23387412
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.