These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

289 related articles for article (PubMed ID: 20673613)

  • 1. Coherent and incoherent effects on the imaging and scattering process in transmission electron microscopy and off-axis electron holography.
    Koch W; Lubk A; Grossmann F; Lichte H; Schmidt R
    Ultramicroscopy; 2010 Oct; 110(11):1397-403. PubMed ID: 20673613
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of the elliptical illumination on acquisition and correction of coherent aberrations in high-resolution electron holography.
    Lehmann M
    Ultramicroscopy; 2004 Jul; 100(1-2):9-23. PubMed ID: 15219689
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The statistics of the thermal motion of the atoms during imaging process in transmission electron microscopy and related techniques.
    Rother A; Gemming T; Lichte H
    Ultramicroscopy; 2009 Jan; 109(2):139-46. PubMed ID: 19027234
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A proposal for the holographic correction of incoherent aberrations by tilted reference waves.
    Röder F; Lubk A
    Ultramicroscopy; 2015 May; 152():63-74. PubMed ID: 25680104
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electron holography with a Cs-corrected transmission electron microscope.
    Geiger D; Lichte H; Linck M; Lehmann M
    Microsc Microanal; 2008 Feb; 14(1):68-81. PubMed ID: 18096096
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A flux-preserving non-linear inline holography reconstruction algorithm for partially coherent electrons.
    Koch CT
    Ultramicroscopy; 2008 Jan; 108(2):141-50. PubMed ID: 17485172
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Lattice-resolution contrast from a focused coherent electron probe. Part I.
    Allen LJ; Findlay SD; Oxley MP; Rossouw CJ
    Ultramicroscopy; 2003 Jul; 96(1):47-63. PubMed ID: 12623171
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Practical image restoration of thick biological specimens using multiple focus levels in transmission electron microscopy.
    Han KF; Sedat JW; Agard DA
    J Struct Biol; 1997 Dec; 120(3):237-44. PubMed ID: 9441929
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrashort electron pulses for diffraction, crystallography and microscopy: theoretical and experimental resolutions.
    Gahlmann A; Tae Park S; Zewail AH
    Phys Chem Chem Phys; 2008 May; 10(20):2894-909. PubMed ID: 18473038
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tutorial on off-axis electron holography.
    Lehmann M; Lichte H
    Microsc Microanal; 2002 Dec; 8(6):447-66. PubMed ID: 12533207
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Linear versus non-linear structural information limit in high-resolution transmission electron microscopy.
    Van Aert S; Chen JH; Van Dyck D
    Ultramicroscopy; 2010 Oct; 110(11):1404-10. PubMed ID: 20655146
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Lattice-resolution contrast from a focused coherent electron probe. Part II.
    Findlay SD; Allen LJ; Oxley MP; Rossouw CJ
    Ultramicroscopy; 2003 Jul; 96(1):65-81. PubMed ID: 12623172
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Off-axis electron holography without Fresnel fringes.
    Yamamoto K; Hirayama T; Tanji T
    Ultramicroscopy; 2004 Nov; 101(2-4):265-9. PubMed ID: 15450672
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Averaging scheme for atomic resolution off-axis electron holograms.
    Niermann T; Lehmann M
    Micron; 2014 Aug; 63():28-34. PubMed ID: 24568718
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transfer and reconstruction of the density matrix in off-axis electron holography.
    Röder F; Lubk A
    Ultramicroscopy; 2014 Nov; 146():103-16. PubMed ID: 25156951
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Practical considerations for high spatial and temporal resolution dynamic transmission electron microscopy.
    Armstrong MR; Boyden K; Browning ND; Campbell GH; Colvin JD; DeHope WJ; Frank AM; Gibson DJ; Hartemann F; Kim JS; King WE; LaGrange TB; Pyke BJ; Reed BW; Shuttlesworth RM; Stuart BC; Torralva BR
    Ultramicroscopy; 2007; 107(4-5):356-67. PubMed ID: 17169490
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modelling imaging based on core-loss spectroscopy in scanning transmission electron microscopy.
    Findlay SD; Oxley MP; Pennycook SJ; Allen LJ
    Ultramicroscopy; 2005 Sep; 104(2):126-40. PubMed ID: 15982522
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Phase measurement of atomic resolution image using transport of intensity equation.
    Ishizuka K; Allman B
    J Electron Microsc (Tokyo); 2005 Jun; 54(3):191-7. PubMed ID: 16076863
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Relativistic effects in elastic scattering of electrons in TEM.
    Rother A; Scheerschmidt K
    Ultramicroscopy; 2009 Jan; 109(2):154-60. PubMed ID: 19026491
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Observation of surfaces by reflection electron holography.
    Osakabe N
    Microsc Res Tech; 1992 Feb; 20(4):457-62. PubMed ID: 1498359
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.