These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

239 related articles for article (PubMed ID: 20679081)

  • 1. Distal enlargement of the optic nerve sheath in the hyperacute stage of intracerebral haemorrhage.
    Skoloudík D; Herzig R; Fadrná T; Bar M; Hradílek P; Roubec M; Jelínková M; Sanák D; Král M; Chmelová J; Herman M; Langová K; Kanovsky P
    Br J Ophthalmol; 2011 Feb; 95(2):217-21. PubMed ID: 20679081
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure.
    Major R; Girling S; Boyle A
    Emerg Med J; 2011 Aug; 28(8):679-81. PubMed ID: 20713366
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Optic nerve sonography - the non-invasive evaluation of intracranial pressure].
    Luberda M; Stachura K; Moskała M
    Przegl Lek; 2013; 70(11):983-5. PubMed ID: 24697043
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage.
    Naldi A; Pivetta E; Coppo L; Cantello R; Comi C; Stecco A; Cerrato P; Lesmeister M; Lochner P
    J Neuroimaging; 2019 May; 29(3):394-399. PubMed ID: 30714259
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fetal optic nerve sheath measurement as a non-invasive tool for assessment of increased intracranial pressure.
    Haratz K; Viñals F; Lev D; Feit H; Ben-Sira L; Lerman-Sagie T; Malinger G
    Ultrasound Obstet Gynecol; 2011 Dec; 38(6):646-51. PubMed ID: 21584889
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The diagnostic performance of ultrasonographic optic nerve sheath diameter and color Doppler indices of the ophthalmic arteries in detecting elevated intracranial pressure.
    Tarzamni MK; Derakhshan B; Meshkini A; Merat H; Fouladi DF; Mostafazadeh S; Rezakhah A
    Clin Neurol Neurosurg; 2016 Feb; 141():82-8. PubMed ID: 26771156
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dilated Optic Nerve Sheath Diameter Predicts Poor Outcome in Acute Spontaneous Intracerebral Hemorrhage.
    Xu H; Li Y; Liu J; Chen Z; Chen Q; Xiang Y; Zhang M; He W; Zhuang Y; Yang Y; Chen W; Chen Y
    Cerebrovasc Dis; 2022; 51(2):199-206. PubMed ID: 34569518
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optic nerve sonographic examination to predict raised intracranial pressure in idiopathic intracranial hypertension: The cut-off points.
    Kishk NA; Ebraheim AM; Ashour AS; Badr NM; Eshra MA
    Neuroradiol J; 2018 Oct; 31(5):490-495. PubMed ID: 30024291
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noninvasive assessment of the intracranial pressure in non-traumatic intracranial hemorrhage.
    Vaiman M; Sigal T; Kimiagar I; Bekerman I
    J Clin Neurosci; 2016 Dec; 34():177-181. PubMed ID: 27612672
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-resolution transbulbar ultrasonography helping differentiate intracranial hypertension in bilateral optic disc oedema patients.
    Chen Q; Chen W; Wang M; Sun X; Sha Y; Li Z; Tian G
    Acta Ophthalmol; 2017 Sep; 95(6):e481-e485. PubMed ID: 28616896
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dilated optic nerve sheath by ultrasound predicts mortality among patients with acute intracerebral hemorrhage.
    Dias FA; Zotin MCZ; Alessio-Alves FF; Martins Filho RKDV; Barreira CMA; Vincenzi OC; Venturelli PM; Boulouis G; Goldstein JN; Pontes-Neto OM
    Arq Neuropsiquiatr; 2023 Oct; 81(10):861-867. PubMed ID: 37939718
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optic nerve ultrasound for detection of intracranial hypertension in intracranial hemorrhage patients: confirmation of previous findings in a different patient population.
    Moretti R; Pizzi B
    J Neurosurg Anesthesiol; 2009 Jan; 21(1):16-20. PubMed ID: 19098619
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Alterations in optic nerve sheath diameter according to cerebrovascular disease sub-groups.
    Gökcen E; Caltekin İ; Savrun A; Korkmaz H; Savrun ŞT; Yıldırım G
    Am J Emerg Med; 2017 Nov; 35(11):1607-1611. PubMed ID: 28473274
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sonography of optic nerve sheath diameter identifies patients with middle cerebral artery infarction at risk of a malignant course: a pilot prospective observational study.
    Lochner P; Fassbender K; Andrejewski A; Behnke S; Wagenpfeil G; Fousse M; Helwig SA; Lesmeister M; Stolz E; Reith W; Brigo F; Yilmaz U
    J Neurol; 2020 Sep; 267(9):2713-2720. PubMed ID: 32440922
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Role of serial ultrasonic optic nerve sheath diameter monitoring in head injury.
    Thotakura AK; Marabathina NR; Danaboyina AR; Mareddy RR
    Neurochirurgie; 2017 Dec; 63(6):444-448. PubMed ID: 29122307
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The quantitative evaluation of intracranial pressure by optic nerve sheath diameter/eye diameter CT measurement.
    Bekerman I; Sigal T; Kimiagar I; Ben Ely A; Vaiman M
    Am J Emerg Med; 2016 Dec; 34(12):2336-2342. PubMed ID: 27717720
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optic Nerve Sheath Diameter is not a predictor of functional outcomes in ICH Patients.
    Vagal VS; Aziz YN; Gusler MT; Patel NM; Sekar P; Behymer TP; Woo D
    J Stroke Cerebrovasc Dis; 2024 Aug; 33(8):107831. PubMed ID: 38914358
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath.
    Blaivas M; Theodoro D; Sierzenski PR
    Acad Emerg Med; 2003 Apr; 10(4):376-81. PubMed ID: 12670853
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure.
    Kim DY; Kim SY; Hong DY; Sung BY; Lee S; Paik JH; Jung HM
    Clin Neurol Neurosurg; 2021 May; 204():106609. PubMed ID: 33813371
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography.
    Jeon JP; Lee SU; Kim SE; Kang SH; Yang JS; Choi HJ; Cho YJ; Ban SP; Byoun HS; Kim YS
    PLoS One; 2017; 12(9):e0183170. PubMed ID: 28902893
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.