These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 20683155)

  • 1. A full-range, multi-variable, CFD-based methodology to identify abnormal near-wall hemodynamics in a stented coronary artery.
    Murphy JB; Boyle FJ
    Biorheology; 2010; 47(2):117-32. PubMed ID: 20683155
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of different stent designs on local hemodynamics in stented arteries.
    Balossino R; Gervaso F; Migliavacca F; Dubini G
    J Biomech; 2008; 41(5):1053-61. PubMed ID: 18215394
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.
    LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation.
    Martin DM; Murphy EA; Boyle FJ
    Med Eng Phys; 2014 Aug; 36(8):1047-56. PubMed ID: 24953569
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations.
    Beier S; Ormiston J; Webster M; Cater J; Norris S; Medrano-Gracia P; Young A; Cowan B
    Ann Biomed Eng; 2016 Feb; 44(2):315-29. PubMed ID: 26178872
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hydrodynamic effects of compliance mismatch in stented arteries.
    Selvarasu NK; Tafti DK; Vlachos PP
    J Biomech Eng; 2011 Feb; 133(2):021008. PubMed ID: 21280880
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of bifurcation angle and other anatomical characteristics on blood flow - A computational study of non-stented and stented coronary arteries.
    Beier S; Ormiston J; Webster M; Cater J; Norris S; Medrano-Gracia P; Young A; Cowan B
    J Biomech; 2016 Jun; 49(9):1570-1582. PubMed ID: 27062590
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery.
    Morlacchi S; Chiastra C; Gastaldi D; Pennati G; Dubini G; Migliavacca F
    J Biomech Eng; 2011 Dec; 133(12):121010. PubMed ID: 22206427
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On the necessity of modelling fluid-structure interaction for stented coronary arteries.
    Chiastra C; Migliavacca F; Martínez MÁ; Malvè M
    J Mech Behav Biomed Mater; 2014 Jun; 34():217-30. PubMed ID: 24607760
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accurate prediction of wall shear stress in a stented artery: newtonian versus non-newtonian models.
    Mejia J; Mongrain R; Bertrand OF
    J Biomech Eng; 2011 Jul; 133(7):074501. PubMed ID: 21823750
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Augmentation of wall shear stress inhibits neointimal hyperplasia after stent implantation: inhibition through reduction of inflammation?
    Carlier SG; van Damme LC; Blommerde CP; Wentzel JJ; van Langehove G; Verheye S; Kockx MM; Knaapen MW; Cheng C; Gijsen F; Duncker DJ; Stergiopulos N; Slager CJ; Serruys PW; Krams R
    Circulation; 2003 Jun; 107(21):2741-6. PubMed ID: 12742998
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Developed pulsatile flow in a deployed coronary stent.
    Banerjee RK; Devarakonda SB; Rajamohan D; Back LH
    Biorheology; 2007; 44(2):91-102. PubMed ID: 17538201
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Survey of coronary stents development for restenosis prevention].
    Chen J; Ni Z; Gu X
    Zhongguo Yi Liao Qi Xie Za Zhi; 2009 Nov; 33(6):429-34. PubMed ID: 20352916
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Time-dependent 3D simulations of the hemodynamics in a stented coronary artery.
    Faik I; Mongrain R; Leask RL; Rodes-Cabau J; Larose E; Bertrand O
    Biomed Mater; 2007 Mar; 2(1):S28-37. PubMed ID: 18458417
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vascular cell adhesion molecule-1 expression in endothelial cells exposed to physiological coronary wall shear stresses.
    O'Keeffe LM; Muir G; Piterina AV; McGloughlin T
    J Biomech Eng; 2009 Aug; 131(8):081003. PubMed ID: 19604015
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery.
    LaDisa JF; Olson LE; Guler I; Hettrick DA; Audi SH; Kersten JR; Warltier DC; Pagel PS
    J Appl Physiol (1985); 2004 Jul; 97(1):424-30; discussion 416. PubMed ID: 14766776
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computation of hemodynamics in the left coronary artery with variable angulations.
    Chaichana T; Sun Z; Jewkes J
    J Biomech; 2011 Jul; 44(10):1869-78. PubMed ID: 21550611
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The conical stent in coronary artery improves hemodynamics compared with the traditional cylindrical stent.
    Yu Y; Zhou Y; Ma Q; Jia S; Wu S; Sun Y; Liu X; Zhao Y; Liu Y; Shi D
    Int J Cardiol; 2017 Jan; 227():166-171. PubMed ID: 27863293
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel design of a noncylindric stent with beneficial effects on flow characteristics: an experimental and numerical flow study in an axisymmetric arterial model with sequential mild stenoses.
    Papaioannou TG; Christofidis CCh; Mathioulakis DS; Stefanadis CI
    Artif Organs; 2007 Aug; 31(8):627-38. PubMed ID: 17651118
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Hemodynamics analysis of intravascular stents with different design features].
    Liang D; Yang D
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Dec; 23(6):1241-4. PubMed ID: 17228717
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.