175 related articles for article (PubMed ID: 2068904)
1. Audiometric estimation error with the ABR in high risk infants.
Hyde ML; Malizia K; Riko K; Alberti PW
Acta Otolaryngol; 1991; 111(2):212-9. PubMed ID: 2068904
[TBL] [Abstract][Full Text] [Related]
2. Predicting the type of hearing loss using click auditory brainstem response in babies referred from newborn hearing screening.
Baldwin M; Watkin P
Ear Hear; 2014; 35(1):1-9. PubMed ID: 24105268
[TBL] [Abstract][Full Text] [Related]
3. Predicting the degree of hearing loss using click auditory brainstem response in babies referred from newborn hearing screening.
Baldwin M; Watkin P
Ear Hear; 2013; 34(3):361-9. PubMed ID: 23340456
[TBL] [Abstract][Full Text] [Related]
4. Audiometric accuracy of the click ABR in infants at risk for hearing loss.
Hyde ML; Riko K; Malizia K
J Am Acad Audiol; 1990 Apr; 1(2):59-66. PubMed ID: 2132587
[TBL] [Abstract][Full Text] [Related]
5. Field sensitivity of targeted neonatal hearing screening using the Nottingham ABR Screener.
Mason S; Davis A; Wood S; Farnsworth A
Ear Hear; 1998 Apr; 19(2):91-102. PubMed ID: 9562531
[TBL] [Abstract][Full Text] [Related]
6. Infant air and bone conduction tone burst auditory brain stem responses for classification of hearing loss and the relationship to behavioral thresholds.
Vander Werff KR; Prieve BA; Georgantas LM
Ear Hear; 2009 Jun; 30(3):350-68. PubMed ID: 19322084
[TBL] [Abstract][Full Text] [Related]
7. Long-term audiometric follow-up of click-evoked auditory brainstem response in hearing-impaired infants.
Schoonhoven R; Lamoré PJ; de Laat JA; Grote JJ
Audiology; 2000; 39(3):135-45. PubMed ID: 10905399
[TBL] [Abstract][Full Text] [Related]
8. Auditory steady-state response and auditory brainstem response thresholds in children.
Swanepoel D; Ebrahim S
Eur Arch Otorhinolaryngol; 2009 Feb; 266(2):213-9. PubMed ID: 18560866
[TBL] [Abstract][Full Text] [Related]
9. Electric response audiometry in infants and preschool children. Long-term control of the results.
Garrubba V; Grandori F; Lamoretti M; Nicolai P; Zanetti D; Antonelli AR
Acta Otolaryngol Suppl; 1991; 482():36-43; discussion 44. PubMed ID: 1897360
[TBL] [Abstract][Full Text] [Related]
10. Using a combination of click- and tone burst-evoked auditory brain stem response measurements to estimate pure-tone thresholds.
Gorga MP; Johnson TA; Kaminski JR; Beauchaine KL; Garner CA; Neely ST
Ear Hear; 2006 Feb; 27(1):60-74. PubMed ID: 16446565
[TBL] [Abstract][Full Text] [Related]
11. Using click-evoked auditory brainstem response thresholds in infants to estimate the corresponding pure-tone audiometry thresholds in children referred from UNHS.
Lu TM; Wu FW; Chang H; Lin HC
Int J Pediatr Otorhinolaryngol; 2017 Apr; 95():57-62. PubMed ID: 28576534
[TBL] [Abstract][Full Text] [Related]
12. Auditory-steady-state response reliability in the audiological diagnosis after neonatal hearing screening.
Núñez-Batalla F; Noriega-Iglesias S; Guntín-García M; Carro-Fernández P; Llorente-Pendás JL
Acta Otorrinolaringol Esp; 2016; 67(4):193-200. PubMed ID: 26454645
[TBL] [Abstract][Full Text] [Related]
13. Diagnostic accuracy of CE Chirp.
Biagio-de Jager L; van Dyk Z; Vinck BH
Int J Pediatr Otorhinolaryngol; 2020 Aug; 135():110071. PubMed ID: 32497908
[TBL] [Abstract][Full Text] [Related]
14. Comparison of auditory steady-state responses and auditory brainstem responses in audiometric assessment of adults with sensorineural hearing loss.
Lin YH; Ho HC; Wu HP
Auris Nasus Larynx; 2009 Apr; 36(2):140-5. PubMed ID: 18620826
[TBL] [Abstract][Full Text] [Related]
15. Analysis of click-evoked auditory brainstem responses using time domain cross-correlations between interleaved responses.
Berninger E; Olofsson A; Leijon A
Ear Hear; 2014; 35(3):318-29. PubMed ID: 24557002
[TBL] [Abstract][Full Text] [Related]
16. Newborn hearing screening on infants at risk.
Ohl C; Dornier L; Czajka C; Chobaut JC; Tavernier L
Int J Pediatr Otorhinolaryngol; 2009 Dec; 73(12):1691-5. PubMed ID: 19796829
[TBL] [Abstract][Full Text] [Related]
17. Auditory brainstem response (ABR) to rarefaction and condensation clicks in normal and abnormal ears.
Borg E; Löfqvist L
Scand Audiol; 1982; 11(4):227-35. PubMed ID: 7163765
[TBL] [Abstract][Full Text] [Related]
18. Steady-state evoked potential and behavioral hearing thresholds in a group of children with absent click-evoked auditory brain stem response.
Rance G; Dowell RC; Rickards FW; Beer DE; Clark GM
Ear Hear; 1998 Feb; 19(1):48-61. PubMed ID: 9504272
[TBL] [Abstract][Full Text] [Related]
19. Thresholds for auditory brain stem responses to tones in notched noise from infants and young children with normal hearing or sensorineural hearing loss.
Stapells DR; Gravel JS; Martin BA
Ear Hear; 1995 Aug; 16(4):361-71. PubMed ID: 8549892
[TBL] [Abstract][Full Text] [Related]
20. [Brain stem audiometry and unconventional audiometry in small children--a comparison with pure-tone audiometry performed at a later time].
Jensen JH; Ostri BJ
Ugeskr Laeger; 1991 Apr; 153(15):1055-7. PubMed ID: 2024330
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]