These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 20693011)

  • 21. [Titanium, steel and their combination in bone surgery].
    Rüedi Th; Perren SM; Pohler O; Riede U
    Langenbecks Arch Chir; 1975; Suppl():395-8. PubMed ID: 1207267
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of the effect of bracket and archwire composition on frictional forces in the buccal segments.
    Nair SV; Padmanabhan R; Janardhanam P
    Indian J Dent Res; 2012; 23(2):203-8. PubMed ID: 22945710
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biocompatibility of gold and stainless steel chains used for forced eruption of impacted teeth - an in vitro investigation.
    Zingler S; Erber R; Lux CJ; Seeberger R; Bister D; Ludwig B
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2013 Aug; 116(2):159-68. PubMed ID: 23643583
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Bonding of autopolymerizing acrylic resins to magnetic stainless steel alloys using metal conditioner.
    Shimizu H; Tsue F; Chen ZX; Kawaguchi T; Takahashi Y
    J Dent; 2008 Feb; 36(2):138-42. PubMed ID: 18191011
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Porcelain veneering of titanium--clinical and technical aspects.
    Haag P
    Swed Dent J Suppl; 2011; (217):11-75. PubMed ID: 22338822
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Electrochemistry of galvanic couples between carbon and common metallic biomaterials in the presence of crevices.
    Silva RA; Barbosa MA; Jenkins GM; Sutherland I
    Biomaterials; 1990 Jul; 11(5):336-40. PubMed ID: 2400800
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release.
    Summer B; Fink U; Zeller R; Rueff F; Maier S; Roider G; Thomas P
    Contact Dermatitis; 2007 Jul; 57(1):35-9. PubMed ID: 17577355
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.
    Jain R; Podworny N; Hearn T; Anderson GI; Schemitsch EH
    J Orthop Trauma; 1997 Oct; 11(7):490-5. PubMed ID: 9334950
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Characterization and cytotoxicity of ions released from stainless steel and nickel-titanium orthodontic alloys.
    Eliades T; Pratsinis H; Kletsas D; Eliades G; Makou M
    Am J Orthod Dentofacial Orthop; 2004 Jan; 125(1):24-9. PubMed ID: 14718875
    [TBL] [Abstract][Full Text] [Related]  

  • 30. In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires.
    Verstrynge A; Van Humbeeck J; Willems G
    Am J Orthod Dentofacial Orthop; 2006 Oct; 130(4):460-70. PubMed ID: 17045145
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Study of corrosion between a titanium implant and dental alloys.
    Reclaru L; Meyer JM
    J Dent; 1994 Jun; 22(3):159-68. PubMed ID: 8027459
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Notch sensitivity of titanium alloy, commercially pure titanium, and stainless steel spinal implants.
    Dick JC; Bourgeault CA
    Spine (Phila Pa 1976); 2001 Aug; 26(15):1668-72. PubMed ID: 11474353
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A computational evaluation of the effect of intramedullary nail material properties on the stabilization of simulated femoral shaft fractures.
    Perez A; Mahar A; Negus C; Newton P; Impelluso T
    Med Eng Phys; 2008 Jul; 30(6):755-60. PubMed ID: 17905637
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A comparison of stainless steel and nickel-titanium H-type instruments of identical design: torsional and bending tests.
    Kazemi RB; Stenman E; Spångberg LS
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2000 Oct; 90(4):500-6. PubMed ID: 11027388
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Particles, sweat, and tears: a comparative study on bioaccessibility of ferrochromium alloy and stainless steel particles, the pure metals and their metal oxides, in simulated skin and eye contact.
    Hedberg Y; Midander K; Wallinder IO
    Integr Environ Assess Manag; 2010 Jul; 6(3):456-68. PubMed ID: 20821707
    [TBL] [Abstract][Full Text] [Related]  

  • 37. In vitro corrosion of Ti-6Al-4V and type 316L stainless steel when galvanically coupled with carbon.
    Thompson NG; Buchanan RA; Lemons JE
    J Biomed Mater Res; 1979 Jan; 13(1):35-44. PubMed ID: 429383
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Dimensional changes of one-piece frameworks cast from titanium, base metal, or noble metal alloys and supported on telescopic crowns.
    Gebelein M; Richter G; Range U; Reitemeier B
    J Prosthet Dent; 2003 Feb; 89(2):193-200. PubMed ID: 12616241
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Promising in vitro performances of a new nickel-free stainless steel.
    Montanaro L; Cervellati M; Campoccia D; Arciola CR
    J Mater Sci Mater Med; 2006 Mar; 17(3):267-75. PubMed ID: 16555119
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Multicycle mechanical performance of titanium and stainless steel transpedicular spine implants.
    Pienkowski D; Stephens GC; Doers TM; Hamilton DM
    Spine (Phila Pa 1976); 1998 Apr; 23(7):782-8. PubMed ID: 9563108
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.