BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 20696471)

  • 21. Sirolimus-eluting biodegradable poly-L-lactide stent for peripheral vascular application: a preliminary study in porcine carotid arteries.
    Bünger CM; Grabow N; Sternberg K; Kröger C; Ketner L; Schmitz KP; Kreutzer HJ; Ince H; Nienaber CA; Klar E; Schareck W
    J Surg Res; 2007 May; 139(1):77-82. PubMed ID: 17292417
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Tissue response to poly(L-lactic acid)-based blend with phospholipid polymer for biodegradable cardiovascular stents.
    Kim HI; Ishihara K; Lee S; Seo JH; Kim HY; Suh D; Kim MU; Konno T; Takai M; Seo JS
    Biomaterials; 2011 Mar; 32(9):2241-7. PubMed ID: 21185597
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Efficacy of a polyphosphazene nanocoat in reducing thrombogenicity, in-stent stenosis, and inflammatory response in porcine renal and iliac artery stents.
    Henn C; Satzl S; Christoph P; Kurz P; Radeleff B; Stampfl U; Stampfl S; Berger I; Richter GM
    J Vasc Interv Radiol; 2008 Mar; 19(3):427-37. PubMed ID: 18295704
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biodegradable polymeric microspheres and nanospheres for drug delivery in the peritoneum.
    Kohane DS; Tse JY; Yeo Y; Padera R; Shubina M; Langer R
    J Biomed Mater Res A; 2006 May; 77(2):351-61. PubMed ID: 16425240
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The effect of pH on the degradation of biodegradable poly(L-lactide-co-glycolide) 80/20 urethral stent material in vitro.
    Juuti H; Kotsar A; Mikkonen J; Isotalo T; Talja M; Tammela TL; Törmälä P; Kellomäki M
    J Endourol; 2012 Jun; 26(6):701-5. PubMed ID: 22192097
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Mechanism(s) of increased vascular cell adhesion on nanostructured poly(lactic-co-glycolic acid) films.
    Miller DC; Haberstroh KM; Webster TJ
    J Biomed Mater Res A; 2005 Jun; 73(4):476-84. PubMed ID: 15880725
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Biological evaluation of materials for cardiovascular application: the role of the short-term inflammatory response in endothelial regeneration.
    Boccafoschi F; Mosca C; Ramella M; Carmagnola I; Chiono V; Ciardelli G; Cannas M
    J Biomed Mater Res A; 2013 Nov; 101(11):3131-40. PubMed ID: 23529998
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biocompatibility and degradation characteristics of PLGA-based electrospun nanofibrous scaffolds with nanoapatite incorporation.
    Ji W; Yang F; Seyednejad H; Chen Z; Hennink WE; Anderson JM; van den Beucken JJ; Jansen JA
    Biomaterials; 2012 Oct; 33(28):6604-14. PubMed ID: 22770568
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Muraglitazar-eluting bioabsorbable vascular stent inhibits neointimal hyperplasia in porcine iliac arteries.
    Uurto I; Hämäläinen M; Suominen V; Laurila M; Kotsar A; Isotalo T; Tammela TL; Kellomäki M; Salenius JP
    J Vasc Interv Radiol; 2015 Jan; 26(1):124-30. PubMed ID: 25454655
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Study of patency of vascular grafts manufactured by means of electrospinning].
    Popova IV; Stepanova AO; Plotnikova TA; Sergeevichev DS; Akulov AE; Pokushalov AA; Laktionov PP; Karpenko AA
    Angiol Sosud Khir; 2015; 21(2):136-8, 140-2. PubMed ID: 26035576
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of the biocompatibility of calcium phosphate cement/PLGA microparticle composites.
    Link DP; van den Dolder J; van den Beucken JJ; Cuijpers VM; Wolke JG; Mikos AG; Jansen JA
    J Biomed Mater Res A; 2008 Dec; 87(3):760-9. PubMed ID: 18200545
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Poly(epsilon-caprolactone) and poly (L-lactic-co-glycolic acid) degradable polymer sponges attenuate astrocyte response and lesion growth in acute traumatic brain injury.
    Wong DY; Hollister SJ; Krebsbach PH; Nosrat C
    Tissue Eng; 2007 Oct; 13(10):2515-23. PubMed ID: 17655492
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biocompatibility of tetramethylpyrazine-eluting stents in normal porcine coronary arteries.
    Ma GS; Chen LJ; Chen Z; Ding S; Shen CX; Feng Y
    Biomed Pharmacother; 2008 Feb; 62(2):125-9. PubMed ID: 17764890
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Vitamin-C delivery from CoCr alloy surfaces using polymer-free and polymer-based platforms for cardiovascular stent applications.
    Thiruppathi E; Mani G
    Langmuir; 2014 Jun; 30(21):6237-49. PubMed ID: 24832897
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Biodegradable braided poly(lactic-co-glycolic acid) urethral stent combined with dutasteride in the treatment of acute urinary retention due to benign prostatic enlargement: a pilot study.
    Kotsar A; Isotalo T; Juuti H; Mikkonen J; Leppiniemi J; Hänninen V; Kellomäki M; Talja M; Tammela TL
    BJU Int; 2009 Mar; 103(5):626-9. PubMed ID: 18990149
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of the SYNERGY with the PROMUS (XIENCE V) and bare metal and polymer-only Element control stents in porcine coronary arteries.
    Wilson GJ; Huibregtse BA; Pennington DE; Dawkins KD
    EuroIntervention; 2012 Jun; 8(2):250-7. PubMed ID: 22717928
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Long-term biocompatibility evaluation of a novel polymer-coated stent in a porcine coronary stent model.
    Huang Y; Liu X; Wang L; Li S; Verbeken E; De Scheerder I
    Coron Artery Dis; 2003 Aug; 14(5):401-8. PubMed ID: 12878906
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Paclitaxel releasing films consisting of poly(vinyl alcohol)-graft-poly(lactide-co-glycolide) and their potential as biodegradable stent coatings.
    Westedt U; Wittmar M; Hellwig M; Hanefeld P; Greiner A; Schaper AK; Kissel T
    J Control Release; 2006 Mar; 111(1-2):235-46. PubMed ID: 16466824
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Mechanical properties and in vitro degradation of bioresorbable fibers and expandable fiber-based stents.
    Zilberman M; Nelson KD; Eberhart RC
    J Biomed Mater Res B Appl Biomater; 2005 Aug; 74(2):792-9. PubMed ID: 15991233
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of the vascular responses to balloon-expandable stenting in the coronary and peripheral circulations: long-term results in an animal model using the TriMaxx stent.
    Dubé H; Clifford AG; Barry CM; Schwarten DE; Schwartz LB
    J Vasc Surg; 2007 Apr; 45(4):821-7. PubMed ID: 17398392
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.