124 related articles for article (PubMed ID: 20696948)
1. Medical devices and the FDA approval process: balancing safety and innovation; comment on "prevalence of fracture and fragment embolization of bard retrievable vena cava filters and clinical implications including cardiac perforation and tamponade".
Redberg RF
Arch Intern Med; 2010 Nov; 170(20):1831-3. PubMed ID: 20696948
[No Abstract] [Full Text] [Related]
2. Prevalence of fracture and fragment embolization of Bard retrievable vena cava filters and clinical implications including cardiac perforation and tamponade.
Nicholson W; Nicholson WJ; Tolerico P; Taylor B; Solomon S; Schryver T; McCullum K; Goldberg H; Mills J; Schuler B; Shears L; Siddoway L; Agarwal N; Tuohy C
Arch Intern Med; 2010 Nov; 170(20):1827-31. PubMed ID: 20696949
[TBL] [Abstract][Full Text] [Related]
3. Correction to article about prevalence of fracture and fragment embolization of Bard retrievable vena cava filters.
Nicholson WJ
Arch Intern Med; 2012 Jun; 172(12):972. PubMed ID: 22732763
[No Abstract] [Full Text] [Related]
4. Fragmentation, embolization, and left ventricular perforation of a recovery filter.
Desjardins B; Kamath SH; Williams D
J Vasc Interv Radiol; 2010 Aug; 21(8):1293-6. PubMed ID: 20598567
[TBL] [Abstract][Full Text] [Related]
5. Cardiac perforation and tamponade: the deadly duo of central venous catheters.
Yoder D
Int J Trauma Nurs; 2001; 7(3):108-12. PubMed ID: 11477392
[No Abstract] [Full Text] [Related]
6. Long-term retrievability of IVC filters: should we abandon permanent devices?
Berczi V; Bottomley JR; Thomas SM; Taneja S; Gaines PA; Cleveland TJ
Cardiovasc Intervent Radiol; 2007; 30(5):820-7. PubMed ID: 17763901
[TBL] [Abstract][Full Text] [Related]
7. Perforation of the heart by an inferior vena cava filter.
Bolton JW; Aldea GS
Mil Med; 1994 Apr; 159(4):360-2. PubMed ID: 20058439
[TBL] [Abstract][Full Text] [Related]
8. Intracardiac embolization of inferior vena cava filter associated with right atrium perforation and cardiac tamponade.
Soeiro Ade M; Fernandes FL; Teixeira RP; Nicz PF; Soeiro MC; Serrano CV; Oliveira MT
Rev Bras Cir Cardiovasc; 2014; 29(2):285-8. PubMed ID: 25140481
[TBL] [Abstract][Full Text] [Related]
9. Bard Denali inferior vena cava filter fracture and embolization resulting in cardiac tamponade: a device failure analysis.
Kuo WT; Robertson SW
J Vasc Interv Radiol; 2015 Jan; 26(1):111-5.e1. PubMed ID: 25541449
[TBL] [Abstract][Full Text] [Related]
10. Complications of inferior vena cava filters.
Passman MA
J Vasc Surg Venous Lymphat Disord; 2017 Jan; 5(1):7. PubMed ID: 27987613
[No Abstract] [Full Text] [Related]
11. A needle through the heart: rare complication of inferior vena caval filters.
Kalavakunta JK; Thomas CS; Gupta V
J Invasive Cardiol; 2009 Nov; 21(11):E221-3. PubMed ID: 19901424
[TBL] [Abstract][Full Text] [Related]
12. Error in Figure 2 and Footnote Addition for Table 2 in: Prevalence of Fracture and Fragment Embolization of Bard Retrievable Vena Cava Filters and Clinical Implications Including Cardiac Perforation and Tamponade.
Arch Intern Med; 2012 Jun; 172(12):958. PubMed ID: 23752815
[No Abstract] [Full Text] [Related]
13. Inferior vena cava filters. Indications, safety, effectiveness.
Becker DM; Philbrick JT; Selby JB
Arch Intern Med; 1992 Oct; 152(10):1985-94. PubMed ID: 1417371
[TBL] [Abstract][Full Text] [Related]
14. Retrievable vena cava filters for preventing pulmonary embolism in trauma patients: a cautionary tale.
Antevil JL; Sise MJ; Sack DI; Sasadeusz KJ; Swanson SM; Rivera L; Lome BR; Weingarten KE; Kaminski SS
J Trauma; 2006 Jan; 60(1):35-40. PubMed ID: 16456434
[TBL] [Abstract][Full Text] [Related]
15. Retrievable vena cava filters in trauma patients for high-risk prophylaxis and prevention of pulmonary embolism.
Allen TL; Carter JL; Morris BJ; Harker CP; Stevens MH
Am J Surg; 2005 Jun; 189(6):656-61. PubMed ID: 15910715
[TBL] [Abstract][Full Text] [Related]
16. The safety and effectiveness of the retrievable option inferior vena cava filter: a United States prospective multicenter clinical study.
Johnson MS; Nemcek AA; Benenati JF; Baumann DS; Dolmatch BL; Kaufman JA; Garcia MJ; Stecker MS; Venbrux AC; Haskal ZJ; Avelar RL
J Vasc Interv Radiol; 2010 Aug; 21(8):1173-84. PubMed ID: 20598570
[TBL] [Abstract][Full Text] [Related]
17. Inferior vena cava filters in trauma patients: efficacy, morbidity, and retrievability.
Smoot RL; Koch CA; Heller SF; Sabater EA; Cullinane DC; Bannon MP; Thomsen KM; Harmsen WS; Baerga-Varela Y; Schiller HJ
J Trauma; 2010 Apr; 68(4):899-903. PubMed ID: 20386285
[TBL] [Abstract][Full Text] [Related]
18. OptEase and TrapEase vena cava filters: a single-center experience in 258 patients.
Onat L; Ganiyusufoglu AK; Mutlu A; Sirvanci M; Duran C; Ulusoy OL; Hamzaoglu A
Cardiovasc Intervent Radiol; 2009 Sep; 32(5):992-7. PubMed ID: 19449061
[TBL] [Abstract][Full Text] [Related]
19. An overview of FDA medical device regulation as it relates to deep brain stimulation devices.
Peña C; Bowsher K; Costello A; De Luca R; Doll S; Li K; Schroeder M; Stevens T
IEEE Trans Neural Syst Rehabil Eng; 2007 Sep; 15(3):421-4. PubMed ID: 17894274
[TBL] [Abstract][Full Text] [Related]
20. Ins and outs of inferior vena cava filters in patients with venous thromboembolism: the experience at Monash Medical Centre and review of the published reports.
Seshadri T; Tran H; Lau KK; Tan B; Gan TE
Intern Med J; 2008 Jan; 38(1):38-43. PubMed ID: 17916166
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]