458 related articles for article (PubMed ID: 20702923)
1. An oscillating sweeping gap test for VMAT quality assurance.
Bhagwat MS; Han Z; Ng SK; Zygmanski P
Phys Med Biol; 2010 Sep; 55(17):5029-44. PubMed ID: 20702923
[TBL] [Abstract][Full Text] [Related]
2. A novel method for routine quality assurance of volumetric-modulated arc therapy.
Wang Q; Dai J; Zhang K
Med Phys; 2013 Oct; 40(10):101712. PubMed ID: 24089902
[TBL] [Abstract][Full Text] [Related]
3. A real time dose monitoring and dose reconstruction tool for patient specific VMAT QA and delivery.
Tyagi N; Yang K; Gersten D; Yan D
Med Phys; 2012 Dec; 39(12):7194-204. PubMed ID: 23231270
[TBL] [Abstract][Full Text] [Related]
4. Quality assurance of volumetric modulated arc therapy using Elekta Synergy.
Haga A; Nakagawa K; Shiraishi K; Itoh S; Terahara A; Yamashita H; Ohtomo K; Saegusa S; Imae T; Yoda K; Pellegrini R
Acta Oncol; 2009; 48(8):1193-7. PubMed ID: 19863228
[TBL] [Abstract][Full Text] [Related]
5. Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.
Létourneau D; Publicover J; Kozelka J; Moseley DJ; Jaffray DA
Med Phys; 2009 May; 36(5):1813-21. PubMed ID: 19544800
[TBL] [Abstract][Full Text] [Related]
6. Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging.
Zwan BJ; Barnes MP; Hindmarsh J; Lim SB; Lovelock DM; Fuangrod T; O'Connor DJ; Keall PJ; Greer PB
Med Phys; 2017 Aug; 44(8):3909-3922. PubMed ID: 28564208
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of MatriXX for IMRT and VMAT dose verifications in peripheral dose regions.
Han Z; Ng SK; Bhagwat MS; Lyatskaya Y; Zygmanski P
Med Phys; 2010 Jul; 37(7):3704-14. PubMed ID: 20831078
[TBL] [Abstract][Full Text] [Related]
8. A generalized inverse planning tool for volumetric-modulated arc therapy.
Cao D; Afghan MK; Ye J; Chen F; Shepard DM
Phys Med Biol; 2009 Nov; 54(21):6725-38. PubMed ID: 19841516
[TBL] [Abstract][Full Text] [Related]
9. Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma.
Bai S; Li G; Wang M; Jiang Q; Zhang Y; Wei Y
Med Dosim; 2013; 38(2):143-7. PubMed ID: 23402928
[TBL] [Abstract][Full Text] [Related]
10. Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning.
Yang Y; Xing L
Med Phys; 2003 Mar; 30(3):433-41. PubMed ID: 12674244
[TBL] [Abstract][Full Text] [Related]
11. Verification of a rounded leaf-end MLC model used in a radiotherapy treatment planning system.
Williams MJ; Metcalfe P
Phys Med Biol; 2006 Feb; 51(4):N65-78. PubMed ID: 16467576
[TBL] [Abstract][Full Text] [Related]
12. Dose reconstruction for volumetric modulated arc therapy (VMAT) using cone-beam CT and dynamic log files.
Qian J; Lee L; Liu W; Chu K; Mok E; Luxton G; Le QT; Xing L
Phys Med Biol; 2010 Jul; 55(13):3597-610. PubMed ID: 20526034
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric discrepancies caused by differing MLC parameters for dynamic IMRT.
Wasbø E; Valen H
Phys Med Biol; 2008 Jan; 53(2):405-15. PubMed ID: 18184995
[TBL] [Abstract][Full Text] [Related]
14. Development of a novel quality assurance system based on rolled-up and rolled-out radiochromic films in volumetric modulated arc therapy.
Park JY; Lee JW; Choi KS; Lee JS; Kim YH; Hong S; Suh TS
Med Phys; 2011 Dec; 38(12):6688-96. PubMed ID: 22149851
[TBL] [Abstract][Full Text] [Related]
15. Development of a novel methodology for QA of respiratory-gated and VMAT beam delivery using Octavius 4D phantom.
Yang B; Geng H; Ding Y; Kong CW; Cheung CW; Chiu TL; Lam WW; Cheung KY; Yu SK
Med Dosim; 2019 Spring; 44(1):83-90. PubMed ID: 29602598
[TBL] [Abstract][Full Text] [Related]
16. Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT.
Yang Y; Xing L; Li JG; Palta J; Chen Y; Luxton G; Boyer A
Med Phys; 2003 Nov; 30(11):2937-47. PubMed ID: 14655941
[TBL] [Abstract][Full Text] [Related]
17. Commissioning and quality assurance for intensity modulated radiotherapy with dynamic multileaf collimator: experience of the Pontificia Universidad Católica de Chile.
Venencia CD; Besa P
J Appl Clin Med Phys; 2004; 5(3):37-54. PubMed ID: 15753938
[TBL] [Abstract][Full Text] [Related]
18. RapidArc patient specific mechanical delivery accuracy under extreme mechanical limits using linac log files.
Wijesooriya K; Aliotta E; Benedict S; Read P; Rich T; Larner J
Med Phys; 2012 Apr; 39(4):1846-53. PubMed ID: 22482606
[TBL] [Abstract][Full Text] [Related]
19. Commissioning and quality assurance of RapidArc radiotherapy delivery system.
Ling CC; Zhang P; Archambault Y; Bocanek J; Tang G; Losasso T
Int J Radiat Oncol Biol Phys; 2008 Oct; 72(2):575-81. PubMed ID: 18793960
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID.
Mohammadi M; Bezak E
Phys Med Biol; 2007 Jan; 52(1):N21-33. PubMed ID: 17183123
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]