These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

83 related articles for article (PubMed ID: 20706482)

  • 1. Formulas for Fabry-Perot velocimeter performance using both stripe and multifrequency techniques.
    Goosman DR
    Appl Opt; 1991 Sep; 30(27):3907-23. PubMed ID: 20706482
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Image plane detector for Fabry-Perot interferometers: physical model and improvement with anticoincidence detection.
    Hays PB; Wang J
    Appl Opt; 1991 Aug; 30(22):3100-7. PubMed ID: 20706360
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analytical description of a fabry-perot spectrometer. 3: off-axis behavior and interference filters.
    Hernandez G
    Appl Opt; 1974 Nov; 13(11):2654-61. PubMed ID: 20134750
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analytical model for low finesse, external cavity, fiber Fabry-Perot interferometers including multiple reflections and angular misalignment.
    Wilkinson PR; Pratt JR
    Appl Opt; 2011 Aug; 50(23):4671-80. PubMed ID: 21833146
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fabry-perot spectrometer adjustment for the compensation of Doppler shift from rapidly rotating and rapidly flowing sources.
    Trauger JT; Roesler FL
    Appl Opt; 1972 Sep; 11(9):1964-9. PubMed ID: 20119266
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Decoding the spectra of low-finesse extrinsic optical fiber Fabry-Perot interferometers.
    Ma C; Dong B; Gong J; Wang A
    Opt Express; 2011 Nov; 19(24):23727-42. PubMed ID: 22109399
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analytical description of a Fabry-Perot spectrometer. 7: TESS, a high-luminosity high-resolution twin-etalon scanning spectrometer.
    Hernandez G
    Appl Opt; 1982 Feb; 21(3):507-13. PubMed ID: 20372485
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Phase-conjugate holographic system for high-resolution particle-image velocimetry.
    Barnhart DH; Adrian RJ; Papen GC
    Appl Opt; 1994 Oct; 33(30):7159-70. PubMed ID: 20941270
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fabry-Perot fringe enhancement.
    Gilson VA
    Appl Opt; 1967 Jul; 6(7):1217-9. PubMed ID: 20062166
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A twelve-channel multiple-interferometer fabry-perot spectrometer.
    Daehler M
    Appl Opt; 1970 Nov; 9(11):2529-34. PubMed ID: 20094300
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nonlinear optical processing with Fabry-Perot interferometers containing phase recording media.
    Bartholomew BJ; Lee SH
    Appl Opt; 1980 Jan; 19(2):201-6. PubMed ID: 20216830
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Luminous flux amplification in Fabry-Perot spectrometry.
    Dupoisot H; Prat R; Slansky S
    Appl Opt; 1978 Dec; 17(24):3930-2. PubMed ID: 20208637
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Force sensitivity and fringe contrast characteristics of spheroidal Fabry-Perot interferometers.
    Wei G; Jiang Q
    Opt Express; 2020 Aug; 28(17):24586-24598. PubMed ID: 32906998
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A moiré fringe method of Fabry-Perot spectrometer scanning.
    Shepherd GG; Paffrath L
    Appl Opt; 1967 Oct; 6(10):1659-63. PubMed ID: 20062284
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-precision velocimetry: optimization of a fabry-perot interferometer.
    Courteville A; Salvadé Y; Dändliker R
    Appl Opt; 2000 Apr; 39(10):1521-6. PubMed ID: 18345045
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reflection and transmission properties of holographic mirrors and holographic Fabry-Perot filters. Ill. Holographic Fabry-Perot filters.
    Wang W
    Appl Opt; 1994 Dec; 33(34):7883-94. PubMed ID: 20963002
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High resolution laser induced fluorescence Doppler velocimetry utilizing saturated absorption spectroscopy.
    Aramaki M; Ogiwara K; Etoh S; Yoshimura S; Tanaka MY
    Rev Sci Instrum; 2009 May; 80(5):053505. PubMed ID: 19485505
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Response of scanning Fabry-Perot interferometers to asymmetric spectral line profiles.
    Bielski A; Bobkowski R; Szudy J
    Appl Opt; 1988 Sep; 27(18):3864-8. PubMed ID: 20539478
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fabry-Perot with short pulse lasers: spectral selection and spectral analysis in dye lasers.
    Daussy H; Dumanchin R; de Witte O
    Appl Opt; 1978 Feb; 17(3):451-8. PubMed ID: 20174429
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fabry-Perot-interferometer imaging system for thermospheric temperature and wind measurements.
    Sivjee GG; Hallinan TJ; Swenson GR
    Appl Opt; 1980 Jul; 19(13):2206-9. PubMed ID: 20221209
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.