These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 20709637)

  • 1. From vascular corrosion cast to electrical analog model for the study of human liver hemodynamics and perfusion.
    Debbaut C; Monbaliu D; Casteleyn C; Cornillie P; Van Loo D; Masschaele B; Pirenne J; Simoens P; Van Hoorebeke L; Segers P
    IEEE Trans Biomed Eng; 2011 Jan; 58(1):25-35. PubMed ID: 20709637
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hypothermic machine perfusion of the liver and the critical balance between perfusion pressures and endothelial injury.
    't Hart NA; van der Plaats A; Leuvenink HG; van Goor H; Wiersema-Buist J; Verkerke GJ; Rakhorst G; Ploeg RJ
    Transplant Proc; 2005; 37(1):332-4. PubMed ID: 15808634
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ex-vivo study of flow dynamics and endothelial cell structure during extended hypothermic machine perfusion preservation of livers.
    Jain S; Xu H; Duncan H; Jones JW; Zhang JX; Clemens MG; Lee CY
    Cryobiology; 2004 Jun; 48(3):322-32. PubMed ID: 15157780
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of flow and addition of oxygen during porcine liver hypothermic machine perfusion.
    Vekemans K; Liu Q; Brassil J; Komuta M; Pirenne J; Monbaliu D
    Transplant Proc; 2007 Oct; 39(8):2647-51. PubMed ID: 17954199
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flow competition between hepatic arterial and portal venous flow during hypothermic machine perfusion preservation of porcine livers.
    Monbaliu DR; Debbaut C; Hillewaert WJ; Laleman WJ; Sainz-Barriga M; Pirenne J; Segers P
    Int J Artif Organs; 2012 Feb; 35(2):119-31. PubMed ID: 22388941
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inhibition of TXA synthesis with OKY-046 improves liver preservation by prolonged hypothermic machine perfusion in rats.
    Xu H; Lee CY; Clemens MG; Zhang JX
    J Gastroenterol Hepatol; 2008 Jul; 23(7 Pt 2):e212-20. PubMed ID: 17645480
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.
    van der Plaats A; Maathuis MH; 'T Hart NA; Bellekom AA; Hofker HS; van der Houwen EB; Verkerke GJ; Leuvenink HG; Verdonck P; Ploeg RJ; Rakhorst G
    Ann Biomed Eng; 2006 Dec; 34(12):1924-34. PubMed ID: 17066322
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hypothermic machine perfusion of liver grafts for transplantation: technical development in human discard and miniature swine models.
    Guarrera JV; Estevez J; Boykin J; Boyce R; Rashid J; Sun S; Arrington B
    Transplant Proc; 2005; 37(1):323-5. PubMed ID: 15808631
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation and calibration of an electrical analog model of human liver perfusion based on hypothermic machine perfusion experiments.
    Debbaut C; Monbaliu DR; Segers P
    Int J Artif Organs; 2014 Jun; 37(6):486-98. PubMed ID: 24980258
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Engineering point of view on liver transplantation strategies: multi-level modeling of hepatic perfusion.
    Debbaut C; Monbaliu D; Segers P
    Transplant Proc; 2014 Nov; 46(9):3143-6. PubMed ID: 25420845
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modeling the impact of partial hepatectomy on the hepatic hemodynamics using a rat model.
    Debbaut C; De Wilde D; Casteleyn C; Cornillie P; Van Loo D; Van Hoorebeke L; Monbaliu D; Fan YD; Segers P
    IEEE Trans Biomed Eng; 2012 Dec; 59(12):3293-303. PubMed ID: 22588575
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hypothermic Liver Machine Perfusion With EKPS-1 Solution vs Aqix RS-I Solution: In Vivo Feasibility Study in a Pig Transplantation Model.
    Vekemans K; Liu Q; Heedfeld V; Van de Vel K; Wylin T; Pirenne J; Monbaliu D
    Transplant Proc; 2009 Mar; 41(2):617-21. PubMed ID: 19328939
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of an adequate perfusion pressure for continuous dual vessel hypothermic machine perfusion of the rat liver.
    't Hart NA; der van Plaats A; Leuvenink HG; van Goor H; Wiersema-Buist J; Verkerke GJ; Rakhorst G; Ploeg RJ
    Transpl Int; 2007 Apr; 20(4):343-52. PubMed ID: 17326775
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The influence of storage temperature during machine perfusion on preservation quality of marginal donor livers.
    Olschewski P; Gass P; Ariyakhagorn V; Jasse K; Hunold G; Menzel M; Schöning W; Schmitz V; Neuhaus P; Puhl G
    Cryobiology; 2010 Jun; 60(3):337-43. PubMed ID: 20233587
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hypothermic machine perfusion of rat livers preserves endothelial cell function.
    Xu H; Zhang JX; Jones JW; Southard JH; Clemens MG; Lee CY
    Transplant Proc; 2005; 37(1):335-7. PubMed ID: 15808635
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hepatic function in hypothermically stored porcine livers: comparison of hypothermic machine perfusion vs cold storage.
    Jain S; Lee CY; Baicu S; Duncan H; Xu H; Jones JW; Clemens MG; Brassil J; Taylor MJ; Brockbank KG
    Transplant Proc; 2005; 37(1):340-1. PubMed ID: 15808637
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiofrequency ablation (RFA): development of a flow model for bovine livers for extensive bench testing.
    Lubienski A; Bitsch RG; Lubienski K; Kauffmann G; Duex M
    Cardiovasc Intervent Radiol; 2006; 29(6):1068-72. PubMed ID: 16845558
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemodynamic, biochemical, and morphological characteristics during preservation of normal porcine livers by hypothermic machine perfusion.
    Monbaliu D; Vekemans K; De Vos R; Brassil J; Heedfeld V; Qiang L; D'hollander M; Roskams T; Pirenne J
    Transplant Proc; 2007 Oct; 39(8):2652-8. PubMed ID: 17954200
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved microcirculation by low-viscosity histidine- tryptophan-ketoglutarate graft flush and subsequent cold storage in University of Wisconsin solution: results of an orthotopic rat liver transplantation model.
    Olschewski P; Hunold G; Eipel C; Neumann U; Schöning W; Schmitz V; Vollmar B; Neuhaus P; Puhl G
    Transpl Int; 2008 Dec; 21(12):1175-80. PubMed ID: 18699843
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved kidney graft function after preservation using a novel hypothermic machine perfusion device.
    Maathuis MH; Manekeller S; van der Plaats A; Leuvenink HG; 't Hart NA; Lier AB; Rakhorst G; Ploeg RJ; Minor T
    Ann Surg; 2007 Dec; 246(6):982-8; discussion 989-91. PubMed ID: 18043100
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.