These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

247 related articles for article (PubMed ID: 20715426)

  • 1. [Insertion procedure of the Swan-Ganz catheter].
    Narumiya C; Isobe F
    Kyobu Geka; 2010 Jul; 63(8 Suppl):607-11. PubMed ID: 20715426
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Pulmonary artery catheterization in 9071 cardiac surgery patients: a review of complications].
    Procaccini B; Clementi G
    Ital Heart J Suppl; 2004 Dec; 5(12):891-9. PubMed ID: 15709458
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Swan-Ganz catheter-induced severe complications in cardiac surgery: right ventricular perforation, knotting, and rupture of a pulmonary artery.
    Bossert T; Gummert JF; Bittner HB; Barten M; Walther T; Falk V; Mohr FW
    J Card Surg; 2006; 21(3):292-5. PubMed ID: 16684066
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Vertebral arteriovenous fistula as a result of Swan-Ganz catheter insertion: surgical correction in a symptomatic patient.
    Majeski JA
    Int Surg; 1999; 84(1):74-7. PubMed ID: 10421023
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulmonary artery pseudoaneurysm after Swan-Ganz catheterization: a case presentation and review of literature.
    Nellaiyappan M; Omar HR; Justiz R; Sprenker C; Camporesi EM; Mangar D
    Eur Heart J Acute Cardiovasc Care; 2014 Sep; 3(3):281-8. PubMed ID: 24470440
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Indications for Swan-Ganz catheterization.
    Hebert KA; Glancy DL
    Heart Dis Stroke; 1994; 3(4):196-200. PubMed ID: 7921663
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Intracardial knotting of a Swan-Ganz catheter. Description of a clinical case].
    Barbagli R; Campolo MC; Cominelli E
    Minerva Anestesiol; 1994 Apr; 60(4):211-4. PubMed ID: 8090321
    [TBL] [Abstract][Full Text] [Related]  

  • 8. How to insert a pulmonary arterial flotation catheter.
    Pierce T; Woodcock T
    Br J Hosp Med; 1989 Dec; 42(6):484-7. PubMed ID: 2611473
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.
    Corley A; Barnett AG; Mullany D; Fraser JF
    Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A knot in the heart.
    Ahmed H; Kaufman D; Zenilman ME
    Am Surg; 2008 Mar; 74(3):235-6. PubMed ID: 18376690
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Swan-Ganz catheters: past, present, and future. A viewpoint.
    Chatterjee K
    Circulation; 2009 Jan; 119(1):147-52. PubMed ID: 19124674
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Swan-Ganz catheter (pulmonary artery catheter)].
    Neya K
    Kyobu Geka; 2009 Jul; 62(8 Suppl):677-81. PubMed ID: 20715691
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Complications caused by a Swan-Ganz catheter. An inadvertent entrapment in the right atrium during cardiac surgery].
    Seitz W; Kaukemüller J; Frank G
    Anaesthesist; 1989 May; 38(5):259-61. PubMed ID: 2735522
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transfemoral percutaneous removal of a knotted Swan-Ganz catheter.
    Katsikis A; Karavolias G; Voudris V
    Catheter Cardiovasc Interv; 2009 Nov; 74(5):802-4. PubMed ID: 19830792
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The Swan-Ganz catheter: nursing role in catheter insertion and patient monitoring].
    Feldker W; Hilscher G
    Dtsch Krankenpflegez; 1991 Feb; 44(2):86-9. PubMed ID: 1900772
    [No Abstract]   [Full Text] [Related]  

  • 16. [Intracardiac knotting of a Swan-Ganz catheter. Detection using intraoperative trans-esophageal echocardiography].
    Galán Serrano J; Correa López J; Tarradell Zamora R; Alvarez Escudero J; Moreno Bueno M; Villar Landeira JM
    Rev Esp Anestesiol Reanim; 1991; 38(4):265-7. PubMed ID: 1771289
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous invasive cardiac output monitoring--the Baxter/Edwards Critical-Care Swan Ganz IntelliCath and Viligance system.
    Munro HM; Wood CE; Taylor BL; Smith GB
    Clin Intensive Care; 1994; 5(2):52-5. PubMed ID: 10147254
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Frequency, Indications And Complications Of Pulmonary Artery Catheter Insertion In Adult Open-Heart Surgery Patients Of A Tertiary Care Hospital.
    Ahmed SS; Akhtar MI; Kamal R
    J Ayub Med Coll Abbottabad; 2016; 28(4):793-797. PubMed ID: 28586614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Pulmonary artery catheterization in patients with blood diseases].
    Bychinin MV; Galstyan GM; Shulutko EM; Kulikov SM
    Anesteziol Reanimatol; 2014; (2):64-9. PubMed ID: 25055498
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Diagnostic and therapeutic consequences of pulmonary artery catheters. Prospective evaluation in an intensive care unit].
    Schoenenberger RA; Weiss P; Ritz R
    Schweiz Med Wochenschr; 1995 May; 125(19):959-64. PubMed ID: 7761806
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]