BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

238 related articles for article (PubMed ID: 20715540)

  • 1. [Effect of training period on learning process in endotracheal intubation using Macintosh laryngoscope].
    Hirabayashi Y
    Masui; 2010 Aug; 59(8):1048-52. PubMed ID: 20715540
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope.
    Hirabayashi Y; Seo N
    J Clin Anesth; 2009 Jun; 21(4):268-71. PubMed ID: 19502032
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Comparison of performance of endotracheal intubation by senior residents in anesthesiology using Airway Scope VS Macintosh laryngoscope].
    Hakozaki T; Hirabayashi Y; Seo N
    Masui; 2009 Jan; 58(1):100-2. PubMed ID: 19175024
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison between the Airtraq and Macintosh laryngoscopes for routine airway management by experienced anesthesiologists: a randomized clinical trial.
    Chalkeidis O; Kotsovolis G; Kalakonas A; Filippidou M; Triantafyllou C; Vaikos D; Koutsioumpas E
    Acta Anaesthesiol Taiwan; 2010 Mar; 48(1):15-20. PubMed ID: 20434108
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Guided insertion of the ProSeal laryngeal mask airway is superior to conventional tracheal intubation by first-month anesthesia residents after brief manikin-only training.
    Hohlrieder M; Brimacombe J; von Goedecke A; Keller C
    Anesth Analg; 2006 Aug; 103(2):458-62, table of contents. PubMed ID: 16861434
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the new Viewmax laryngoscope in a simulated difficult airway.
    Leung YY; Hung CT; Tan ST
    Acta Anaesthesiol Scand; 2006 May; 50(5):562-7. PubMed ID: 16643225
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Airtraq optical laryngoscope].
    Hirabayashi Y; Otsuka Y; Taira K; Shinohara T; Kikuchi Y; Shimada N; Kono R; Tamai K; Inoue S; Seo N
    Masui; 2008 Aug; 57(8):1026-30. PubMed ID: 18710017
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [The efficacy of video intubating laryngoscope for novice residents].
    Iwase Y; Matsushima H; Nemoto M; Fujita A; Ozaki M; Ueno K; Oh'ishi S; Higuchi J; Sakio H
    Masui; 2004 Mar; 53(3):313-9. PubMed ID: 15071888
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Assessment of the practice of endotracheal intubation by levering Laryngoscope in teaching of undergraduate medical students].
    Higashizawa T; Bito H; Nishiyama T; Sakai T; Konishi A
    Masui; 1997 Sep; 46(9):1255-8. PubMed ID: 9311221
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Training resident anesthesiologists in adult challenging intubation comparing Truview EVO2 and Macintosh laryngoscope: a preliminary study.
    Carlino C; Pastore JC; Battistini GM; Cancellieri F; De Caria D; Ruggieri N; Bordone G; Bellato V
    Minerva Anestesiol; 2009 Oct; 75(10):563-7. PubMed ID: 19461566
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of McGrath and Macintosh laryngoscopes in novice users: a manikin study.
    Ray DC; Billington C; Kearns PK; Kirkbride R; Mackintosh K; Reeve CS; Robinson N; Stewart CJ; Trudeau T
    Anaesthesia; 2009 Nov; 64(11):1207-10. PubMed ID: 19825056
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Nasotracheal intubation using GlideScope videolaryngoscope or Macintosh laryngoscope by novice laryngoscopists].
    Shimada M; Hirabayashi Y; Seo N
    Masui; 2010 Oct; 59(10):1318-20. PubMed ID: 20960914
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Learning manual skills in spinal anesthesia and orotracheal intubation: is there any recommended number of cases for anesthesia residency training program?
    Charuluxananan S; Kyokong O; Somboonviboon W; Pothimamaka S
    J Med Assoc Thai; 2001 Jun; 84 Suppl 1():S251-5. PubMed ID: 11529340
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tracheal intubation by inexperienced medical residents using the Airtraq and Macintosh laryngoscopes--a manikin study.
    Maharaj CH; Ni Chonghaile M; Higgins BD; Harte BH; Laffey JG
    Am J Emerg Med; 2006 Nov; 24(7):769-74. PubMed ID: 17098095
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Comparison of Cormack/Lehane classification grades decided by novice residents and those by board certified anesthesiologists].
    Shibuya H; Amano E; Konishi A; Nogawa R; Hitomi K; Hirata T
    Masui; 2009 Jul; 58(7):917-21. PubMed ID: 19618837
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Airtraq optical laryngoscope: tracheal intubation by novice laryngoscopists.
    Hirabayashi Y; Seo N
    Emerg Med J; 2009 Feb; 26(2):112-3. PubMed ID: 19164621
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retention of tracheal intubation skills by novice personnel: a comparison of the Airtraq and Macintosh laryngoscopes.
    Maharaj CH; Costello J; Higgins BD; Harte BH; Laffey JG
    Anaesthesia; 2007 Mar; 62(3):272-8. PubMed ID: 17300305
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The GlideScope Ranger video laryngoscope can be useful in airway management of entrapped patients.
    Nakstad AR; Sandberg M
    Acta Anaesthesiol Scand; 2009 Nov; 53(10):1257-61. PubMed ID: 19681773
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
    van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
    Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The regional anesthesia "learning curve". What is the minimum number of epidural and spinal blocks to reach consistency?
    Kopacz DJ; Neal JM; Pollock JE
    Reg Anesth; 1996; 21(3):182-90. PubMed ID: 8744658
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.