These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 20716090)

  • 21. Translaryngeal retrograde wire-guided fiberoptic intubation for difficult airway: a case report.
    Chau-In W; Pongmetha S; Sumret K; Vatanasapt P; Khongkankong W
    J Med Assoc Thai; 2005 Jun; 88(6):845-8. PubMed ID: 16083228
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Tracheal intubation with Pentax AWS Airway Scope after failed fiberoptic intubation and failed insertion of the intubating laryngeal mask airway].
    Asai T; Ito I; Kuremoto Y; Kawashima A
    Masui; 2010 Apr; 59(4):470-2. PubMed ID: 20420136
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A comparison of GlideScope videolaryngoscopy with direct laryngoscopy for nasotracheal intubation in children.
    Kim HJ; Kim JT; Kim HS; Kim CS
    Paediatr Anaesth; 2011 Nov; 21(11):1165-6. PubMed ID: 21966964
    [No Abstract]   [Full Text] [Related]  

  • 24. A case report. The use of the fiberoptic laryngoscope for nasotracheal intubation.
    Triplett WW; Ondrey JS; McDonald JS
    Anesth Prog; 1979; 26(2):49. PubMed ID: 295586
    [No Abstract]   [Full Text] [Related]  

  • 25. Facilitating endotracheal intubation using the GlideScope video laryngoscope in children with difficult airways.
    Xue FS; Liu HP; Liu JH; Liao X; Zhang YM
    Paediatr Anaesth; 2009 Sep; 19(9):918-9. PubMed ID: 19691704
    [No Abstract]   [Full Text] [Related]  

  • 26. The GlideScope and the Bonfils is it the device, the operator, or both?
    Fiadjoe JE; Gurnaney HG; Stricker PA
    Paediatr Anaesth; 2013 Jul; 23(7):673-4. PubMed ID: 23738596
    [No Abstract]   [Full Text] [Related]  

  • 27. Poor visualization during direct laryngoscopy and high upper lip bite test score are predictors of difficult intubation with the GlideScope videolaryngoscope.
    Tremblay MH; Williams S; Robitaille A; Drolet P
    Anesth Analg; 2008 May; 106(5):1495-500, table of contents. PubMed ID: 18420866
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Tracheal intubation in older children with severe retro/micrognathia using the GlideScope Cobalt Infant Video Laryngoscope.
    Karsli C; Der T
    Paediatr Anaesth; 2010 Jun; 20(6):577-8. PubMed ID: 20609122
    [No Abstract]   [Full Text] [Related]  

  • 29. Exchange catheter-assisted fiberoptic nasal intubation: a modified technique.
    Gosavi KS; Nirkhi AM
    Anesth Analg; 2011 Jul; 113(1):205-6. PubMed ID: 21700698
    [No Abstract]   [Full Text] [Related]  

  • 30. Flexible cystofibrescope for difficult intubation.
    Malhotra V
    Can J Anaesth; 1991 Nov; 38(8):1071. PubMed ID: 1752011
    [No Abstract]   [Full Text] [Related]  

  • 31. The use of WuScope fiberoptic laryngoscopy for tracheal intubation in complex clinical situations.
    Sprung J; Weingarten T; Dilger J
    Anesthesiology; 2003 Jan; 98(1):263-5. PubMed ID: 12503006
    [No Abstract]   [Full Text] [Related]  

  • 32. [A comparison of bullard laryngoscope and intubating laryngeal mask using fiberoptic guidance for tracheal intubation].
    Onizuka S; Kawano T; Takasaki M
    Masui; 2000 Jul; 49(7):736-9. PubMed ID: 10933023
    [TBL] [Abstract][Full Text] [Related]  

  • 33. LMA-FasTrach.
    McQuibban GA
    Can J Anaesth; 1998 Jan; 45(1):95-6. PubMed ID: 9466042
    [No Abstract]   [Full Text] [Related]  

  • 34. Direct laryngoscopy with the aid of a fiberoptic bronchoscope for tracheal intubation.
    Abeyewardene L; Ganta R; Henthorn R
    Anesth Analg; 1996 Sep; 83(3):665. PubMed ID: 8780318
    [No Abstract]   [Full Text] [Related]  

  • 35. Fiberoptic-guided intubation via the Laryngeal Mask Airway Supreme.
    Mathes AM; Wrobel M; Reus E; Rensing H; Grundmann U
    J Clin Anesth; 2008 Jun; 20(4):322-3. PubMed ID: 18617140
    [No Abstract]   [Full Text] [Related]  

  • 36. Successful airway management with combined use of Glidescope videolaryngoscope and fiberoptic bronchoscope in a patient with Cowden syndrome.
    Sharma D; Kim LJ; Ghodke B
    Anesthesiology; 2010 Jul; 113(1):253-5. PubMed ID: 20526181
    [No Abstract]   [Full Text] [Related]  

  • 37. A difficult airway case with GlideScope-assisted fiberoptic intubation.
    Vitin AA; Erdman JE
    J Clin Anesth; 2007 Nov; 19(7):564-5. PubMed ID: 18063219
    [No Abstract]   [Full Text] [Related]  

  • 38. The Bonfils intubation fibrescope: clinical evaluation and consideration of the learning curve.
    Corbanese U; Morossi M
    Eur J Anaesthesiol; 2009 Jul; 26(7):622-4. PubMed ID: 19300272
    [No Abstract]   [Full Text] [Related]  

  • 39. Failed fiberoptic intubation in a child with epidermolysis bullosa, rescued with combined use of the Glidescope®.
    Fitzmaurice BC; Lambert BG
    Paediatr Anaesth; 2016 Apr; 26(4):455-6. PubMed ID: 26846727
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Optimizing GlideScope laryngoscopy: an in vitro study on an airway model.
    Dupanović M; Jensen R
    Anesthesiology; 2007 Apr; 106(4):886-8. PubMed ID: 17413944
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.