These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 2071772)
1. CPAP with a Siemens Servo 900C ventilator during weaning in infants. Radermacher P; Breulmann M; Felber HJ; Santak B Intensive Care Med; 1991; 17(3):189. PubMed ID: 2071772 [No Abstract] [Full Text] [Related]
2. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing. Aerts JG; van den Berg B; Bogaard JM Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760 [TBL] [Abstract][Full Text] [Related]
3. Automatic tube compensation during weaning from mechanical ventilation: evidence and clinical implications. Unoki T; Serita A; Grap MJ Crit Care Nurse; 2008 Aug; 28(4):34-42; quiz 43. PubMed ID: 18669705 [No Abstract] [Full Text] [Related]
4. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning. Patel RG; Petrini MF Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020 [TBL] [Abstract][Full Text] [Related]
5. Total inspiratory work with modern demand valve devices compared to continuous flow CPAP. Samodelov LF; Falke KJ Intensive Care Med; 1988; 14(6):632-9. PubMed ID: 3053843 [TBL] [Abstract][Full Text] [Related]
6. [The use of methods of assisted pulmonary ventilation in the weaning of children from ventilator breathing]. Tseloval'nikov IuM; Shtatnov MK; Ostreĭkov IF Anesteziol Reanimatol; 1998; (1):53-5. PubMed ID: 9553264 [No Abstract] [Full Text] [Related]
7. Helmet noninvasive ventilation for weaning from mechanical ventilation. Klein M; Weksler N; Bartal C; Gurman GM Respir Care; 2004 Sep; 49(9):1035-7. PubMed ID: 15329175 [TBL] [Abstract][Full Text] [Related]
9. Pressure characteristics of the Ambu CPAP system and the Servo ventilator 900C in CPAP mode. Zetterström H; Jonsson LO Acta Anaesthesiol Scand; 1987 Jan; 31(1):104-10. PubMed ID: 3548197 [TBL] [Abstract][Full Text] [Related]
10. Weaning from mechanical ventilation. When paediatric intensive care medicine profits from adult experience and vice-versa. Brochard L Intensive Care Med; 2001 Oct; 27(10):1564-6. PubMed ID: 11685295 [No Abstract] [Full Text] [Related]
11. A randomised controlled trial of two methods of delivering nasal continuous positive airway pressure after extubation to infants weighing less than 1000 g: binasal (Hudson) versus single nasal prongs. Davis P; Davies M; Faber B Arch Dis Child Fetal Neonatal Ed; 2001 Sep; 85(2):F82-5. PubMed ID: 11517198 [TBL] [Abstract][Full Text] [Related]
12. [Nasal vs. tracheal CPAP in newborn infants in weaning from artificial respiration]. Guimarães H; Costa V; Moreira HP; Tavares M Arch Pediatr; 1997 Nov; 4(11):1152-3. PubMed ID: 9488761 [No Abstract] [Full Text] [Related]
13. Effects of different CPAP systems on weaning parameters in patients recovering from acute respiratory failure. Tütüncü AS; Cakar N; Esen F; Kesecioğlu J; Telci L Adv Exp Med Biol; 1996; 388():579-83. PubMed ID: 8798862 [No Abstract] [Full Text] [Related]
14. Nasal CPAP for neonates: what do we know in 2003? De Paoli AG; Morley C; Davis PG Arch Dis Child Fetal Neonatal Ed; 2003 May; 88(3):F168-72. PubMed ID: 12719386 [TBL] [Abstract][Full Text] [Related]
15. Nasal continuous positive airway pressure from high flow cannula versus Infant Flow for Preterm infants. Campbell DM; Shah PS; Shah V; Kelly EN J Perinatol; 2006 Sep; 26(9):546-9. PubMed ID: 16837929 [TBL] [Abstract][Full Text] [Related]
16. A randomized, controlled trial comparing two different continuous positive airway pressure systems for the successful extubation of extremely low birth weight infants. Stefanescu BM; Murphy WP; Hansell BJ; Fuloria M; Morgan TM; Aschner JL Pediatrics; 2003 Nov; 112(5):1031-8. PubMed ID: 14595042 [TBL] [Abstract][Full Text] [Related]
17. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators]. Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861 [TBL] [Abstract][Full Text] [Related]
18. Comparison of invasive and noninvasive positive pressure ventilation delivered by means of a helmet for weaning of patients from mechanical ventilation. Carron M; Rossi S; Carollo C; Ori C J Crit Care; 2014 Aug; 29(4):580-5. PubMed ID: 24793658 [TBL] [Abstract][Full Text] [Related]
19. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation. DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147 [TBL] [Abstract][Full Text] [Related]
20. "Minimal ventilator settings" and extubation. Hodgson RE; Richards G Am J Respir Crit Care Med; 2012 Jul; 186(2):198-9; author reply 199-200. PubMed ID: 22798418 [No Abstract] [Full Text] [Related] [Next] [New Search]