289 related articles for article (PubMed ID: 20725754)
21. A novel four-dimensional strategy combining protein and peptide separation methods enables detection of low-abundance proteins in human plasma and serum proteomes.
Tang HY; Ali-Khan N; Echan LA; Levenkova N; Rux JJ; Speicher DW
Proteomics; 2005 Aug; 5(13):3329-42. PubMed ID: 16052622
[TBL] [Abstract][Full Text] [Related]
22. Reversed-phase high-performance liquid chromatographic prefractionation of immunodepleted human serum proteins to enhance mass spectrometry identification of lower-abundant proteins.
Martosella J; Zolotarjova N; Liu H; Nicol G; Boyes BE
J Proteome Res; 2005; 4(5):1522-37. PubMed ID: 16212403
[TBL] [Abstract][Full Text] [Related]
23. iTRAQ compatibility of peptide immobilized pH gradient isoelectric focusing.
Lengqvist J; Uhlén K; Lehtiö J
Proteomics; 2007 Jun; 7(11):1746-52. PubMed ID: 17476709
[TBL] [Abstract][Full Text] [Related]
24. Modeling the isoelectric focusing of peptides in an OFFGEL multicompartment cell.
Lam HT; Josserand J; Lion N; Girault HH
J Proteome Res; 2007 May; 6(5):1666-76. PubMed ID: 17397209
[TBL] [Abstract][Full Text] [Related]
25. Study on stability mechanism of immobilized pH gradient in isoelectric focusing via the Svensson-Tiselius differential equation and moving reaction boundary.
Guo CG; Li S; Wang HY; Zhang D; Li GQ; Zhang J; Fan LY; Cao CX
Talanta; 2013 Jul; 111():20-7. PubMed ID: 23622521
[TBL] [Abstract][Full Text] [Related]
26. Differential radioactive proteomic analysis of microdissected renal cell carcinoma tissue by 54 cm isoelectric focusing in serial immobilized pH gradient gels.
Poznanović S; Wozny W; Schwall GP; Sastri C; Hunzinger C; Stegmann W; Schrattenholz A; Buchner A; Gangnus R; Burgemeister R; Cahill MA
J Proteome Res; 2005; 4(6):2117-25. PubMed ID: 16335957
[TBL] [Abstract][Full Text] [Related]
27. Effect of separation dimensions on resolution and throughput using very narrow-range IEF for 2-DE after solution phase isoelectric fractionation of a complex proteome.
Lee K; Pi K
J Sep Sci; 2009 Apr; 32(8):1237-42. PubMed ID: 19301322
[TBL] [Abstract][Full Text] [Related]
28. Immobilized pH gradient isoelectric focusing as a first-dimension separation in shotgun proteomics.
Cargile BJ; Sevinsky JR; Essader AS; Stephenson JL; Bundy JL
J Biomol Tech; 2005 Sep; 16(3):181-9. PubMed ID: 16461941
[TBL] [Abstract][Full Text] [Related]
29. Use of narrow-range peptide IEF to improve detection of lung adenocarcinoma markers in plasma and pleural effusion.
Pernemalm M; De Petris L; Eriksson H; Brandén E; Koyi H; Kanter L; Lewensohn R; Lehtiö J
Proteomics; 2009 Jul; 9(13):3414-24. PubMed ID: 19609957
[TBL] [Abstract][Full Text] [Related]
30. Optimized peptide separation and identification for mass spectrometry based proteomics via free-flow electrophoresis.
Malmström J; Lee H; Nesvizhskii AI; Shteynberg D; Mohanty S; Brunner E; Ye M; Weber G; Eckerskorn C; Aebersold R
J Proteome Res; 2006 Sep; 5(9):2241-9. PubMed ID: 16944936
[TBL] [Abstract][Full Text] [Related]
31. Narrow-band fractionation of proteins from whole cell lysates using isoelectric membrane focusing and nonporous reversed-phase separations.
Zhu Y; Lubman DM
Electrophoresis; 2004 Apr; 25(7-8):949-58. PubMed ID: 15095432
[TBL] [Abstract][Full Text] [Related]
32. Peptide mapping with mobile phases of intermediate pH value using capillary reversed-phase high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry.
Yang Y; Boysen RI; Harris SJ; Hearn MT
J Chromatogr A; 2009 May; 1216(18):3767-73. PubMed ID: 19285675
[TBL] [Abstract][Full Text] [Related]
33. A versatile peptide pI calculator for phosphorylated and N-terminal acetylated peptides experimentally tested using peptide isoelectric focusing.
Gauci S; van Breukelen B; Lemeer SM; Krijgsveld J; Heck AJ
Proteomics; 2008 Dec; 8(23-24):4898-906. PubMed ID: 19003858
[TBL] [Abstract][Full Text] [Related]
34. Making broad proteome protein measurements in 1-5 min using high-speed RPLC separations and high-accuracy mass measurements.
Shen Y; Strittmatter EF; Zhang R; Metz TO; Moore RJ; Li F; Udseth HR; Smith RD; Unger KK; Kumar D; Lubda D
Anal Chem; 2005 Dec; 77(23):7763-73. PubMed ID: 16316187
[TBL] [Abstract][Full Text] [Related]
35. Interrogation of MS/MS search data with an pI Filter algorithm to increase protein identification success.
Uwaje NC; Mueller NS; Maccarrone G; Turck CW
Electrophoresis; 2007 Jun; 28(12):1867-74. PubMed ID: 17516581
[TBL] [Abstract][Full Text] [Related]
36. Peptide separation with immobilized pI strips is an attractive alternative to in-gel protein digestion for proteome analysis.
Hubner NC; Ren S; Mann M
Proteomics; 2008 Dec; 8(23-24):4862-72. PubMed ID: 19003865
[TBL] [Abstract][Full Text] [Related]
37. Isoelectric point-based prefractionation of proteins from crude biological samples prior to two-dimensional gel electrophoresis.
Sahab ZJ; Suh Y; Sang QX
J Proteome Res; 2005; 4(6):2266-72. PubMed ID: 16335975
[TBL] [Abstract][Full Text] [Related]
38. A miniaturized multichamber solution isoelectric focusing device for separation of protein digests.
Tan A; Pashkova A; Zang L; Foret F; Karger BL
Electrophoresis; 2002 Oct; 23(20):3599-607. PubMed ID: 12412130
[TBL] [Abstract][Full Text] [Related]
39. Divergent-flow isoelectric focusing for separation and preparative analysis of peptides.
Duša F; Křenková J; Moravcová D; Kahle V; Slais K
Electrophoresis; 2012 Jul; 33(12):1687-94. PubMed ID: 22740456
[TBL] [Abstract][Full Text] [Related]
40. Calculation of the isoelectric point of tryptic peptides in the pH 3.5-4.5 range based on adjacent amino acid effects.
Cargile BJ; Sevinsky JR; Essader AS; Eu JP; Stephenson JL
Electrophoresis; 2008 Jul; 29(13):2768-78. PubMed ID: 18615785
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]