159 related articles for article (PubMed ID: 20727307)
21. Primary stability and stiffness in ankle arthrodes-crossed screws versus anterior plating.
Betz MM; Benninger EE; Favre PP; Wieser KK; Vich MM; Espinosa N
Foot Ankle Surg; 2013 Sep; 19(3):168-72. PubMed ID: 23830164
[TBL] [Abstract][Full Text] [Related]
22. [A biomechanical study on internal and external fixation devices for treatment of humeral shaft fracture].
Niu X; Huang F; Cen S; Qin T; Wang R; Shang Z; Liu A; Zheng H
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 May; 22(5):516-9. PubMed ID: 18630425
[TBL] [Abstract][Full Text] [Related]
23. A biomechanical comparison of micromotion after ankle fusion using 2 fixation techniques: intramedullary arthrodesis nail or Ilizarov external fixator.
Fragomen AT; Meyers KN; Davis N; Shu H; Wright T; Rozbruch SR
Foot Ankle Int; 2008 Mar; 29(3):334-41. PubMed ID: 18348832
[TBL] [Abstract][Full Text] [Related]
24. Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants.
Füchtmeier B; May R; Hente R; Maghsudi M; Völk M; Hammer J; Nerlich M; Prantl L
Arch Orthop Trauma Surg; 2007 Aug; 127(6):441-7. PubMed ID: 17457598
[TBL] [Abstract][Full Text] [Related]
25. Tibiotalocalcaneal arthrodesis using a dynamically locked retrograde intramedullary nail.
Pelton K; Hofer JK; Thordarson DB
Foot Ankle Int; 2006 Oct; 27(10):759-63. PubMed ID: 17054874
[TBL] [Abstract][Full Text] [Related]
26. Biomechanical comparison of different fixation methods in tibiotalocalcaneal arthrodesis: a cadaver study.
Trost M; Yarkin S; Knieps M; Frey S; Neiss WF; Eysel P; Gick S; Dargel J
J Orthop Surg Res; 2023 Dec; 18(1):971. PubMed ID: 38105223
[TBL] [Abstract][Full Text] [Related]
27. [Tibiotalocalcaneal arthrodesis using a retrograde nail locked in the sagittal plane].
Veselý R; Procházka V; Visna P; Valentová J; Savolt J
Acta Chir Orthop Traumatol Cech; 2008 Apr; 75(2):129-33. PubMed ID: 18454918
[TBL] [Abstract][Full Text] [Related]
28. Angle-stable and compressed angle-stable locking for tibiotalocalcaneal arthrodesis with retrograde intramedullary nails. Biomechanical evaluation.
Mückley T; Hoffmeier K; Klos K; Petrovitch A; von Oldenburg G; Hofmann GO
J Bone Joint Surg Am; 2008 Mar; 90(3):620-7. PubMed ID: 18310713
[TBL] [Abstract][Full Text] [Related]
29. Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture.
Huh J; Glisson RR; Matsumoto T; Easley ME
Foot Ankle Int; 2016 Apr; 37(4):411-8. PubMed ID: 26637274
[TBL] [Abstract][Full Text] [Related]
30. The effect of implant overlap on the mechanical properties of the femur.
Harris T; Ruth JT; Szivek J; Haywood B
J Trauma; 2003 May; 54(5):930-5. PubMed ID: 12777906
[TBL] [Abstract][Full Text] [Related]
31. Biomechanical evaluation of primary stiffness of tibiotalocalcaneal fusion with intramedullary nails.
Mückley T; Eichorn S; Hoffmeier K; von Oldenburg G; Speitling A; Hoffmann GO; Bühren V
Foot Ankle Int; 2007 Feb; 28(2):224-31. PubMed ID: 17296144
[TBL] [Abstract][Full Text] [Related]
32. Tibiotalocalcaneal arthrodesis: a biomechanical assessment of stability.
Bennett GL; Cameron B; Njus G; Saunders M; Kay DB
Foot Ankle Int; 2005 Jul; 26(7):530-6. PubMed ID: 16045843
[TBL] [Abstract][Full Text] [Related]
33. Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri.
Siffri PC; Peindl RD; Coley ER; Norton J; Connor PM; Kellam JF
J Orthop Trauma; 2006 Sep; 20(8):547-54. PubMed ID: 16990726
[TBL] [Abstract][Full Text] [Related]
34. Tibiotalocalcaneal arthrodesis with intramedullary interlocking nail fixation.
Fox IM; Shapero C; Kennedy A
Clin Podiatr Med Surg; 2000 Jan; 17(1):19-31, v. PubMed ID: 10652653
[TBL] [Abstract][Full Text] [Related]
35. A modified and enhanced test setup for biomechanical investigations of the hindfoot, for example in tibiotalocalcaneal arthrodesis.
Evers J; Schulze M; Gehweiler D; Lakemeier M; Raschke MJ; Wähnert D; Ochman S
BMC Musculoskelet Disord; 2016 Jul; 17():318. PubMed ID: 27472925
[TBL] [Abstract][Full Text] [Related]
36. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate.
Heiney JP; Barnett MD; Vrabec GA; Schoenfeld AJ; Baji A; Njus GO
J Trauma; 2009 Feb; 66(2):443-9. PubMed ID: 19204519
[TBL] [Abstract][Full Text] [Related]
37. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate.
Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L
Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766
[TBL] [Abstract][Full Text] [Related]
38. Biomechanical assessment of anterior lumbar interbody fusion with an anterior lumbosacral fixation screw-plate: comparison to stand-alone anterior lumbar interbody fusion and anterior lumbar interbody fusion with pedicle screws in an unstable human cadaver model.
Gerber M; Crawford NR; Chamberlain RH; Fifield MS; LeHuec JC; Dickman CA
Spine (Phila Pa 1976); 2006 Apr; 31(7):762-8. PubMed ID: 16582849
[TBL] [Abstract][Full Text] [Related]
39. Primary stability of an intramedullary calcaneal nail and an angular stable calcaneal plate in a biomechanical testing model of intraarticular calcaneal fracture.
Goldzak M; Simon P; Mittlmeier T; Chaussemier M; Chiergatti R
Injury; 2014 Jan; 45 Suppl 1():S49-53. PubMed ID: 24219899
[TBL] [Abstract][Full Text] [Related]
40. Torsional stability of intramedullary compression nails: tibial osteotomy model.
Brown NA; Bryan NA; Stevens PM
Clin Biomech (Bristol, Avon); 2007 May; 22(4):449-56. PubMed ID: 17250938
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]