These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 2073487)

  • 1. Speed of injection does not affect subarachnoid distribution of plain bupivacaine 0.5%.
    Stienstra R; Van Poorten F
    Reg Anesth; 1990; 15(4):208-10. PubMed ID: 2073487
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of speed of injection on the maximum sensory level for spinal anesthesia using plain bupivacaine 0.5% at room temperature.
    Bucx MJ; Kroon JW; Stienstra R
    Reg Anesth; 1993; 18(2):103-5. PubMed ID: 8489974
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The temperature of bupivacaine 0.5% affects the sensory level of spinal anesthesia.
    Stienstra R; van Poorten JF
    Anesth Analg; 1988 Mar; 67(3):272-6. PubMed ID: 3344977
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Plain or hyperbaric bupivacaine for spinal anesthesia.
    Stienstra R; van Poorten JF
    Anesth Analg; 1987 Feb; 66(2):171-6. PubMed ID: 3813061
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Spread of spinal anesthesia in patients having perianal surgery in the jackknife position: effects of baricity of 0.5% bupivacaine and positioning during and after induction of spinal anesthesia.
    Ariyama J; Hayashida M; Sugimoto Y; Imanishi H; To-Oyma Y; Kitamura A
    J Clin Anesth; 2009 Sep; 21(6):408-13. PubMed ID: 19833273
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The addition of epinephrine to subarachnoid administered hyperbaric bupivacaine with fentanyl for cesarean delivery: the effect on onset time.
    Moore CH; Wilhite A; Pan PH; Blass NH
    Reg Anesth; 1992; 17(4):202-4. PubMed ID: 1515385
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Needle direction affects the sensory level of spinal anesthesia.
    Stienstra R; van Poorten F; Kroon JW
    Anesth Analg; 1989 Apr; 68(4):497-500. PubMed ID: 2929982
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The influence of epidural volume extension on spinal block with hyperbaric or plain bupivacaine for Caesarean delivery.
    Kucukguclu S; Unlugenc H; Gunenc F; Kuvaki B; Gokmen N; Gunasti S; Guclu S; Yilmaz F; Isik G
    Eur J Anaesthesiol; 2008 Apr; 25(4):307-13. PubMed ID: 17888192
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Level of injection in spinal anesthesia: effect on sensory anesthetic level.
    Becker N; Callesen T; Thage B; Bertelsen F; Christiansen C
    Reg Anesth; 1993; 18(1):44-6. PubMed ID: 8448098
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [The effect of volume and dosage of isobaric bupivacaine on the sensory spread of spinal anesthesia].
    Schmidt A; Schwagmeier R; Broja E; Nolte H
    Reg Anaesth; 1990 Sep; 13(7):159-62. PubMed ID: 2236712
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of the subarachnoid position of microcatheters on onset of analgesia and dose of plain bupivacaine 0.5% in continuous spinal anesthesia.
    Standl T; Beck H
    Reg Anesth; 1994; 19(4):231-6. PubMed ID: 7947422
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Epidural volume extension and intrathecal dose requirement: plain versus hyperbaric bupivacaine.
    Tyagi A; Kumar A; Sethi AK; Mohta M
    Anesth Analg; 2008 Jul; 107(1):333-8. PubMed ID: 18635505
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Barbotage and spinal anaesthesia. The effect of barbotage on the spread of analgesia during isobaric spinal anaesthesia.
    Nightingale PJ
    Anaesthesia; 1983 Jan; 38(1):7-9. PubMed ID: 6824158
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The influence of temperature and speed of injection on the distribution of a solution containing bupivacaine and methylene blue in a spinal canal model.
    Stienstra R; Gielen M; Kroon JW; Van Poorten F
    Reg Anesth; 1990; 15(1):6-11. PubMed ID: 2275917
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spinal anesthesia with plain bupivacaine 0.5%: regression of sensory and motor blockade with different temperatures of the anesthetic solution.
    Stienstra R; Gielen M; van Poorten F; Kroon JW
    Anesth Analg; 1989 Nov; 69(5):593-7. PubMed ID: 2802194
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The effect of injection speed and needle gauge on the spread of sensory blockade in spinal anesthesia].
    Schwagmeier R; Schmidt A; Nolte H
    Reg Anaesth; 1990 Sep; 13(7):148-52. PubMed ID: 2236710
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Influence of injection speed of the spread of 4.0 ml of 0.5% isobaric bupivacaine in spinal anesthesia].
    Nasuhara H; Ohmi S; Yokoyama K
    Masui; 2000 Dec; 49(12):1363-6. PubMed ID: 11193512
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Clinical research of hyperbaric, isobaric, and hypobaric solutions of bupivacaine in continuous spinal anesthesia].
    Yang HW; Bai NY; Guo QL
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2005 Feb; 30(1):84-7. PubMed ID: 15871196
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of hyperbaric bupivacaine temperature on the spread of spinal anesthesia.
    Arai YC; Ueda W; Takimoto E; Manabe M
    Anesth Analg; 2006 Jan; 102(1):272-5. PubMed ID: 16368842
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Continuous spinal anesthesia with hyperbaric bupivacaine: a dose-response analysis.
    Burgess FW; Woiwood MD; Lutz RL; Walz EJ; Perkins DE
    Reg Anesth; 1991; 16(1):52-6. PubMed ID: 2007107
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.