BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 20737585)

  • 1. Does stem preheating have a beneficial effect on PMMA bulk porosity in cemented THA?
    Madrala A; Nuño N; Bureau MN
    J Biomed Mater Res B Appl Biomater; 2010 Oct; 95(1):1-8. PubMed ID: 20737585
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of stem preheating and precooling on residual stress formation at stem/cement interface for cemented hip implants.
    Madrala A; Nuño N
    J Biomed Mater Res B Appl Biomater; 2010 Apr; 93(1):258-65. PubMed ID: 20091924
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [New PMMA bone cements for vacuum mixing systems].
    Schelling K; Heisel C; Schnürer SM; Mau H; Breusch SJ
    Orthopade; 2002 Jun; 31(6):556-62. PubMed ID: 12149927
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Porosity reduction in bone cement at the cement-stem interface.
    Bishop NE; Ferguson S; Tepic S
    J Bone Joint Surg Br; 1996 May; 78(3):349-56. PubMed ID: 8636165
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of preheating of hip prostheses on the stem-cement interface.
    Iesaka K; Jaffe WL; Kummer FJ
    J Bone Joint Surg Am; 2003 Mar; 85(3):421-7. PubMed ID: 12637425
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Vacuum-mixing cement does not decrease overall porosity in cemented femoral stems: an in vitro laboratory investigation.
    Messick KJ; Miller MA; Damron LA; Race A; Clarke MT; Mann KA
    J Bone Joint Surg Br; 2007 Aug; 89(8):1115-21. PubMed ID: 17785755
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of vacuum mixing and pre-heating the femoral component on the mechanical properties of the cement mantle.
    Baleani M; Bialoblocka-Juszczyk E; Engels GE; Viceconti M
    J Bone Joint Surg Br; 2010 Mar; 92(3):454-60. PubMed ID: 20190321
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The significance of the micropores at the stem-cement interface in total hip replacement.
    Zhang H; Blunt L; Jiang X; Brown L; Barrans S
    J Biomater Sci Polym Ed; 2011; 22(7):845-56. PubMed ID: 21144164
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of a new power-operated PMMA vacuum mixing and delivery system for cemented femoral stem insertion.
    Lahav A; DiMaio FR
    Orthopedics; 2004 Jan; 27(1):57-8. PubMed ID: 14763531
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Precooling of the femoral canal enhances shear strength at the cement-prosthesis interface and reduces the polymerization temperature.
    Hsieh PH; Tai CL; Chang YH; Lee MS; Shih HN; Shih CH
    J Orthop Res; 2006 Sep; 24(9):1809-14. PubMed ID: 16865715
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Integrity of the stem-cement interface in THA: effects of stem surface finish and cement porosity.
    Iesaka K; Jaffe WL; Kummer FJ
    J Biomed Mater Res B Appl Biomater; 2008 Oct; 87(1):77-82. PubMed ID: 18386841
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interface gap after implantation of a cemented femoral stem in pigs.
    Wang JS; Franzén H; Lidgren L
    Acta Orthop Scand; 1999 Jun; 70(3):234-9. PubMed ID: 10429597
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of fluid penetration and interfacial porosity on the fixation of cemented femoral components.
    Iesaka K; Jaffe WL; Jones CM; Kummer FJ
    J Bone Joint Surg Br; 2005 Sep; 87(9):1298-302. PubMed ID: 16129762
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The influence of stem insertion rate on the porosity of the cement mantle of hip joint replacements.
    Baleani M; Fognani R; Toni A
    Proc Inst Mech Eng H; 2003; 217(3):199-205. PubMed ID: 12807160
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preheating acrylic bone cement powder is not recommended for all brands.
    Lewis G; Janna S
    J Arthroplasty; 2007 Apr; 22(3):428-34. PubMed ID: 17400099
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pre-heating of components in cemented total hip arthroplasty.
    Jafri AA; Green SM; Partington PF; McCaskie AW; Muller SD
    J Bone Joint Surg Br; 2004 Nov; 86(8):1214-9. PubMed ID: 15568540
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does vacuum mixing affect diameter shrinkage of a PMMA cement mantle during in vitro cemented acetabulum implantation?
    Boote AT; Bigsby RJ; Deehan DJ; Rankin KS; Swailes DC; Hyde PJ
    Proc Inst Mech Eng H; 2021 Feb; 235(2):133-140. PubMed ID: 33054541
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stem-cement porosity may explain early loosening of cemented femoral hip components: experimental-computational in vitro study.
    Mann KA; Damron LA; Miller MA; Race A; Clarke MT; Cleary RJ
    J Orthop Res; 2007 Mar; 25(3):340-50. PubMed ID: 17149748
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty.
    Oonishi H; Akiyama H; Takemoto M; Kawai T; Yamamoto K; Yamamuro T; Oonishi H; Nakamura T
    Acta Orthop; 2011 Oct; 82(5):553-8. PubMed ID: 22103279
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The contradictory effects of pores on fatigue cracking of bone cement.
    Janssen D; Aquarius R; Stolk J; Verdonschot N
    J Biomed Mater Res B Appl Biomater; 2005 Aug; 74(2):747-53. PubMed ID: 15981172
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.