These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 2077094)

  • 21. Challenges in measuring moisture content of feeds.
    Thiex N; Richardson CR
    J Anim Sci; 2003 Dec; 81(12):3255-66. PubMed ID: 14677883
    [TBL] [Abstract][Full Text] [Related]  

  • 22. International consensus on the standardization of sodium and potassium measurements by ion-selective electrodes in undiluted samples.
    Külpmann WR; Höbbel T
    Scand J Clin Lab Invest Suppl; 1996; 224():145-60. PubMed ID: 8865430
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Determination of trace element silver in animal serum, tissues and organs by microwave digestion-ICP-MS].
    Yuan JJ; Xie YZ; Han C; Sun W; Zhang K; Zhao J; Lu X; Lu JX; Ren W
    Guang Pu Xue Yu Guang Pu Fen Xi; 2014 Sep; 34(9):2533-7. PubMed ID: 25532359
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Determination of sodium in foods by flame atomic absorption spectrometry after microwave digestion: NMKL interlaboratory study.
    Julshamn K; Lea P; Norli HS
    J AOAC Int; 2005; 88(4):1212-6. PubMed ID: 16152942
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Analytical evaluation of Kone Microlyte determination of ionized magnesium.
    van Ingen HE; Huijgen HJ; Kok WT; Sanders GT
    Clin Chem; 1994 Jan; 40(1):52-5. PubMed ID: 8287544
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The serum anion gap. Has the reference interval really fallen?
    Roberts WL; Johnson RD
    Arch Pathol Lab Med; 1997 Jun; 121(6):568-72. PubMed ID: 9199620
    [TBL] [Abstract][Full Text] [Related]  

  • 27. On the certification of cadmium at trace and ultratrace levels in standard reference materials using ID ICP-MS.
    Murphy KE; Long SE; Vocke RD
    Anal Bioanal Chem; 2007 Apr; 387(7):2453-61. PubMed ID: 17082873
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The accuracy of laboratory measurements in clinical chemistry: a study of 11 routine chemistry analytes in the College of American Pathologists Chemistry Survey with fresh frozen serum, definitive methods, and reference methods.
    Ross JW; Miller WG; Myers GL; Praestgaard J
    Arch Pathol Lab Med; 1998 Jul; 122(7):587-608. PubMed ID: 9674541
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Speciation analysis of arsenic in prenatal and children's dietary supplements using microwave-enhanced extraction and ion chromatography-inductively coupled plasma mass spectrometry.
    Wolle MM; Rahman GM; Kingston HM; Pamuku M
    Anal Chim Acta; 2014 Mar; 818():23-31. PubMed ID: 24626399
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.
    Tai SS; Welch MJ
    Anal Chem; 2004 Feb; 76(4):1008-14. PubMed ID: 14961732
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Methods of assigning accurate values to reference serum. Part 2. The use of definitive methods, reference laboratories, transferred values and consensus values.
    Eldjarn L; Broughton PM
    Ann Clin Biochem; 1985 Nov; 22 ( Pt 6)():635-49. PubMed ID: 4073795
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Slurry sampling in serum blood for mercury determination by CV-AFS.
    Aranda PR; Gil RA; Moyano S; De Vito I; Martinez LD
    J Hazard Mater; 2009 Jan; 161(2-3):1399-403. PubMed ID: 18572311
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Serum water determination by means of microwave evaporation.
    van Kreel BK; Wulkan RW; Leijnse BL
    J Clin Chem Clin Biochem; 1988 Sep; 26(9):579-81. PubMed ID: 3199080
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Candidate reference measurement procedure for determination of urea in serum by liquid chromatography-tandem mass spectrometry.
    Han L; Huang X; Zhang L; Zhang Q; Wang J; Lin H; Yan J; Zhuang J; Huang X
    J Pharm Biomed Anal; 2019 Jan; 162():124-129. PubMed ID: 30236820
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Comparison of ion-selective electrodes and flame photometry for the determination of serum Na+ and K+ for clinical purposes (author's transl)].
    Preusse CJ; Fuchs C
    J Clin Chem Clin Biochem; 1979 Oct; 17(10):639-45. PubMed ID: 501292
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Determination of 28 selected elements in textiles by axially viewed inductively coupled plasma optical emission spectrometry.
    Rezić I; Zeiner M; Steffan I
    Talanta; 2011 Jan; 83(3):865-71. PubMed ID: 21147330
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improvement of AOAC Official Method 984.27 for the determination of nine nutritional elements in food products by Inductively coupled plasma-atomic emission spectroscopy after microwave digestion: single-laboratory validation and ring trial.
    Poitevin E; Nicolas M; Graveleau L; Richoz J; Andrey D; Monard F
    J AOAC Int; 2009; 92(5):1484-518. PubMed ID: 19916387
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Preparation of Commutable Frozen Human Serum Candidate Reference Materials for Standardization of Sodium Measurements.
    Zhang R; Zhang S; Wang Q
    Clin Lab; 2017 Jul; 63(7):1243-1250. PubMed ID: 28792714
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Application of ICP-OES to the determination of barium in blood and urine in clinical and forensic analysis.
    Lech T
    J Anal Toxicol; 2013 May; 37(4):222-6. PubMed ID: 23471954
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Determination of 13 elements in food by microwave plasma-atomic emission spectrometry].
    Han F; Meng Z; Liu Y; Sun L; Ouyang Kun ; Xie K; Huang Z
    Wei Sheng Yan Jiu; 2016 Jan; 45(1):76-80. PubMed ID: 26987201
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.