These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 2077579)

  • 41. Accuracy of electronic apex locators in comparison to actual length--an in vivo study.
    Haffner C; Folwaczny M; Galler K; Hickel R
    J Dent; 2005 Sep; 33(8):619-25. PubMed ID: 16139692
    [TBL] [Abstract][Full Text] [Related]  

  • 42. An in vivo comparison of two frequency-based electronic apex locators.
    Welk AR; Baumgartner JC; Marshall JG
    J Endod; 2003 Aug; 29(8):497-500. PubMed ID: 12929694
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Accuracy of two root canal length measurement devices integrated into rotary endodontic motors when removing gutta-percha from root-filled teeth.
    Uzun O; Topuz O; Tinaz C; Nekoofar MH; Dummer PM
    Int Endod J; 2008 Sep; 41(9):725-32. PubMed ID: 18637852
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [Clinical study of the efficacy of devices for electronic measurement of the working length].
    Ricci C; Dupont AM; Laurichesse JM
    Rev Fr Endod; 1986 Mar; 5(1):13-26. PubMed ID: 3474721
    [No Abstract]   [Full Text] [Related]  

  • 45. [Predictive value of tactile sense in electronic endodontometry].
    Vachey E; Rougé J; Duguet J; Lemagnen G; Roques JC; Duhamel J
    Rev Fr Endod; 1989 Jun; 8(2):25-32. PubMed ID: 2633226
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Apex locators in endodontics: which, when and how?
    Chong BS; Pitt Ford TR
    Dent Update; 1994 Oct; 21(8):328-30. PubMed ID: 7641954
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Comparisons of meter reading values in 5 electronic measuring devices].
    Shinoda K; Hoji T; Nakashima M; Sekine I; Mukouyama Y
    Gifu Shika Gakkai Zasshi; 1990 Jun; 17(1):246-52. PubMed ID: 2134762
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Electronic conductometry in endodontics. A developing technique].
    António PS; Leopoldo FN; Carmen LP
    Rev Port Estomatol Cir Maxilofac; 1991; 31(4):247-51. PubMed ID: 2041976
    [No Abstract]   [Full Text] [Related]  

  • 49. [Estimation of tooth-length].
    Antoniadou P
    Hell Stomatol Chron; 1988; 32(3):197-205. PubMed ID: 3153699
    [TBL] [Abstract][Full Text] [Related]  

  • 50. [Clinical evaluation of the voltage gradient method for root canal measurement].
    Nakamura M; Nakamura Y
    Shigaku; 1989 Oct; 77(3):930-48. PubMed ID: 2489340
    [TBL] [Abstract][Full Text] [Related]  

  • 51. In vivo evaluation of ProPex electronic apex locator.
    Ozsezer E; Inan U; Aydin U
    J Endod; 2007 Aug; 33(8):974-7. PubMed ID: 17878086
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Bio-electronic determination of endodontic working lengths.
    Felger MR
    US Navy Med; 1973 Jan; 61(1):43-6. PubMed ID: 4620773
    [No Abstract]   [Full Text] [Related]  

  • 53. Influence of the concentration of ions and foramen diameter on the accuracy of electronic root canal length measurement--an experimental study.
    Kovacević M; Tamarut T
    J Endod; 1998 May; 24(5):346-51. PubMed ID: 9641111
    [TBL] [Abstract][Full Text] [Related]  

  • 54. An ex vivo comparison of working length determination by 3 electronic apex locators.
    Pascon EA; Marrelli M; Congi O; Ciancio R; Miceli F; Versiani MA
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Sep; 108(3):e147-51. PubMed ID: 19716484
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Endo-radar: a new electronic system for localization of the apical foramen].
    Collesano V; Brusotti C; Fraternale P
    Dent Cadmos; 1980 May; 48(5):35-41. PubMed ID: 6935085
    [No Abstract]   [Full Text] [Related]  

  • 56. Effect of recapitulation on accuracy of electronically determined canal length.
    Rivera EM; Seraji MK
    Oral Surg Oral Med Oral Pathol; 1993 Aug; 76(2):225-30. PubMed ID: 8361736
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [The role of the Neosono in determining canal length].
    Albou JP
    Rev Odontostomatol (Paris); 1985; 14(6):443-6. PubMed ID: 3869333
    [No Abstract]   [Full Text] [Related]  

  • 58. [Measurement of the working length of a tooth root canal using an electro-metric device of original design].
    Necas J; Broz M
    Prakt Zubn Lek; 1987 Jul; 35(6):172-8. PubMed ID: 3479760
    [No Abstract]   [Full Text] [Related]  

  • 59. [Electronic determination of length of root canals].
    Forabosco A; Mincione E; Cappi PL
    Odontostomatol Implantoprotesi; 1981; (5):12-3, 15. PubMed ID: 6984161
    [No Abstract]   [Full Text] [Related]  

  • 60. A comparison between two electronic apex locators: an ex vivo investigation.
    Venturi M; Breschi L
    Int Endod J; 2007 May; 40(5):362-73. PubMed ID: 17309741
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.