These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

70 related articles for article (PubMed ID: 2078665)

  • 1. [Long-term stability of the detection and threshold behavior of titanium nitride pacemaker electrodes].
    Bolz A; Matlok H; Still M; Schaldach M; Hubmann M; Hardt R
    Biomed Tech (Berl); 1990; 35 Suppl 3():131-3. PubMed ID: 2078665
    [No Abstract]   [Full Text] [Related]  

  • 2. [The detection and stimulus threshold behavior of titanium nitride cardiac pacemaker electrodes].
    Schaldach M; Hubmann M; Hardt R; Weikl A
    Biomed Tech (Berl); 1989; 34 Suppl():54-6. PubMed ID: 2819208
    [No Abstract]   [Full Text] [Related]  

  • 3. [Titanium nitride cardiac pacemaker electrodes].
    Schaldach M; Hubmann M; Hardt R; Weikl A
    Biomed Tech (Berl); 1989; 34(7-8):185-90. PubMed ID: 2775825
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The threshold current and optimal design of cardiac pacemaker electrodes (author's transl)].
    Tamura F; Teraoka K
    Iyodenshi To Seitai Kogaku; 1977 Oct; 15(6):397-402. PubMed ID: 604569
    [No Abstract]   [Full Text] [Related]  

  • 5. [An experimental study on detection impedance of the pacemaker electrodes (author's transl)].
    Tamura F
    Iyodenshi To Seitai Kogaku; 1980 Sep; 18(5):360-4. PubMed ID: 7241847
    [No Abstract]   [Full Text] [Related]  

  • 6. The carbon tip electrode.
    Elmqvist H; Schueller H; Richter G
    Pacing Clin Electrophysiol; 1983 Mar; 6(2 Pt 2):436-9. PubMed ID: 6189089
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Effect of the overall electrical resistance of the tissues on the work of an implanted cardiac pacemaker].
    González N; Vetkin AN; Taín J; Camacho V; Cartina J
    Med Tekh; 1972; 4():58-63. PubMed ID: 4663451
    [No Abstract]   [Full Text] [Related]  

  • 8. Interference in implanted cardiac devices--Part II.
    Irnich W
    Pacing Clin Electrophysiol; 2003 Feb; 26(2 Pt 1):658. PubMed ID: 12710332
    [No Abstract]   [Full Text] [Related]  

  • 9. Polarisation impedance of pacemaker electrodes: in vitro studies simulating practical operation.
    Fischler H; Schwan HP
    Med Biol Eng Comput; 1981 Sep; 19(5):579-88. PubMed ID: 7334866
    [No Abstract]   [Full Text] [Related]  

  • 10. Ti as an anode and as a container for the heart pacemaker--an accelerated test.
    James HI
    Ann Biomed Eng; 1978 Jun; 6(2):93-107. PubMed ID: 717869
    [No Abstract]   [Full Text] [Related]  

  • 11. Signal source impedance of implanted pacemaker electrodes estimated from the spectral ratio between loaded and unloaded electrograms in man.
    Mörkrid L; Ohm OJ; Hammer E
    Med Biol Eng Comput; 1980 Mar; 18(2):223-33. PubMed ID: 7392689
    [No Abstract]   [Full Text] [Related]  

  • 12. [Progress of medical engineering in pacemaker technology].
    Togawa T
    Kokyu To Junkan; 1983 Jul; 31(7):699-703. PubMed ID: 6361938
    [No Abstract]   [Full Text] [Related]  

  • 13. Threshold behavior of electrodes in long-term ventricular pacing.
    Luceri RM; Furman S; Hurzeler P; Escher DJ
    Am J Cardiol; 1977 Aug; 40(2):184-8. PubMed ID: 879024
    [No Abstract]   [Full Text] [Related]  

  • 14. [Effectiveness of detection and stimulation of myocardium with titanium electrodes coated with titanium nitride].
    Shaldakh M; Bolts A; Breme Iu; Khubman M; Khardt R
    Med Tekh; 1994; (1):36-41. PubMed ID: 8208088
    [No Abstract]   [Full Text] [Related]  

  • 15. A new test for pacemaker leads: capacitance measurement.
    Aubert AE; Ector H; De Geest H; Peytier A; Geysen W
    J Electrocardiol; 1978 Oct; 11(4):379-84. PubMed ID: 712289
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Histological evaluation of porous titanium cardiac pacemaker electrode tips.
    Hirshorn MS; Holley LK; Money DK; Spector M; Young FA; Hales JR
    J Biomed Mater Res; 1984 Jan; 18(1):47-60. PubMed ID: 6699032
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Stimulation threshold dynamics and their significance in the construction of cardiac pacemakers and electrodes].
    Peleska V; Vrana M; Blazek Z; Netusil M
    Elektromed Biomed Tech; 1969 Sep; 14(5):177-81. PubMed ID: 5409305
    [No Abstract]   [Full Text] [Related]  

  • 18. Pacemaker electrodes and problems related to cardiac pacing and sensing: current solutions and future trends.
    Pioger G; Garberoglio B
    Life Support Syst; 1984; 2(3):169-81. PubMed ID: 6503346
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Method of introducing electrodes in electric cardiac pacemaker].
    Huch OO; Nesterenko VL
    Klin Khir; 1997; (9-10):105. PubMed ID: 9511369
    [No Abstract]   [Full Text] [Related]  

  • 20. [Local steroid elution via pacemaker electrodes: improved stimulation and sensing functions].
    Schuchert A; Kuck KH
    Dtsch Med Wochenschr; 1992 Apr; 117(16):607-12. PubMed ID: 1568427
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.