These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
149 related articles for article (PubMed ID: 20803771)
1. Personalized image-based templates for precise acetabular prosthesis placement in total hip arthroplasty: a pilot study. Chen B; Xiao SX; Gu PC; Lin XJ J Zhejiang Univ Sci B; 2010 Sep; 11(9):673-80. PubMed ID: 20803771 [TBL] [Abstract][Full Text] [Related]
2. Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip. Zhang YZ; Chen B; Lu S; Yang Y; Zhao JM; Liu R; Li YB; Pei GX Int J Med Robot; 2011 Dec; 7(4):469-74. PubMed ID: 22113980 [TBL] [Abstract][Full Text] [Related]
3. Isolated acetabular revision with femoral stem retention using computed tomography-based navigation. Kubota Y; Kaku N; Tagomori H; Kataoka M; Tsumura H Orthop Traumatol Surg Res; 2019 Nov; 105(7):1311-1317. PubMed ID: 31522901 [TBL] [Abstract][Full Text] [Related]
4. [Computer-assisted surgery for acetabular cup positioning in total hip arthroplasty: comparative prospective randomized study]. Parratte S; Argenson JN; Flecher X; Aubaniac JM Rev Chir Orthop Reparatrice Appar Mot; 2007 May; 93(3):238-46. PubMed ID: 17534206 [TBL] [Abstract][Full Text] [Related]
5. An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position. Tetsunaga T; Yamada K; Tetsunaga T; Sanki T; Kawamura Y; Ozaki T J Orthop Surg Res; 2020 Apr; 15(1):147. PubMed ID: 32295628 [TBL] [Abstract][Full Text] [Related]
6. The validity and reproducibility of cross table radiographs compared with CT scans for the measurement of anteversion of the acetabular component after total hip arthroplasty. Pankaj A; Mittal A; Chawla A Bone Joint J; 2017 Aug; 99-B(8):1006-1011. PubMed ID: 28768776 [TBL] [Abstract][Full Text] [Related]
7. Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography. Bayraktar V; Weber M; von Kunow F; Zeman F; Craiovan B; Renkawitz T; Grifka J; Woerner M Int Orthop; 2017 Apr; 41(4):731-738. PubMed ID: 27277948 [TBL] [Abstract][Full Text] [Related]
8. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty. Ogawa H; Hasegawa S; Tsukada S; Matsubara M J Arthroplasty; 2018 Jun; 33(6):1833-1837. PubMed ID: 29502961 [TBL] [Abstract][Full Text] [Related]
9. Accuracy of computer navigation for acetabular component placement in THA. Ryan JA; Jamali AA; Bargar WL Clin Orthop Relat Res; 2010 Jan; 468(1):169-77. PubMed ID: 19629609 [TBL] [Abstract][Full Text] [Related]
10. Efficacy of a computed tomography-based navigation system for placement of the acetabular component in total hip arthroplasty for developmental dysplasia of the hip. Tsutsui T; Goto T; Wada K; Takasago T; Hamada D; Sairyo K J Orthop Surg (Hong Kong); 2017; 25(3):2309499017727954. PubMed ID: 28851263 [TBL] [Abstract][Full Text] [Related]
11. Haptically guided robotic technology in total hip arthroplasty: a cadaveric investigation. Nawabi DH; Conditt MA; Ranawat AS; Dunbar NJ; Jones J; Banks S; Padgett DE Proc Inst Mech Eng H; 2013 Mar; 227(3):302-9. PubMed ID: 23662346 [TBL] [Abstract][Full Text] [Related]
12. Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study. Lin F; Lim D; Wixson RL; Milos S; Hendrix RW; Makhsous M Clin Biomech (Bristol); 2008 Oct; 23(8):1004-11. PubMed ID: 18541352 [TBL] [Abstract][Full Text] [Related]
13. Value of Computed Tomography-Based Three-Dimensional Pre-operative Planning in Cup Placement in Total Hip Arthroplasty With Dysplastic Acetabulum. Wu P; Liu Q; Fu M; Zhang Z; He S; Liao W; Kang Y J Invest Surg; 2019 Nov; 32(7):607-613. PubMed ID: 30303698 [No Abstract] [Full Text] [Related]
14. Ultrasound-based navigation and 3D CT compared in acetabular cup position. Hasart O; Poepplau BM; Asbach P; Perka C; Wassilew GI Orthopedics; 2009 Oct; 32(10 Suppl):6-10. PubMed ID: 19835299 [TBL] [Abstract][Full Text] [Related]
15. Comparison of native anatomy with recommended safe component orientation in total hip arthroplasty for primary osteoarthritis. Merle C; Grammatopoulos G; Waldstein W; Pegg E; Pandit H; Aldinger PR; Gill HS; Murray DW J Bone Joint Surg Am; 2013 Nov; 95(22):e172. PubMed ID: 24257672 [TBL] [Abstract][Full Text] [Related]
16. Comparison of Three-Dimensional Planning-Assisted and Conventional Acetabular Cup Positioning in Total Hip Arthroplasty: A Randomized Controlled Trial. Sariali E; Boukhelifa N; Catonne Y; Pascal Moussellard H J Bone Joint Surg Am; 2016 Jan; 98(2):108-16. PubMed ID: 26791031 [TBL] [Abstract][Full Text] [Related]
17. Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice? Craiovan B; Weber M; Worlicek M; Schneider M; Springorum HR; Zeman F; Grifka J; Renkawitz T Rofo; 2016 Jun; 188(6):574-81. PubMed ID: 27093395 [TBL] [Abstract][Full Text] [Related]
18. Assessment of Acetabular Component Anteversion after Total Hip Arthroplasty: Comparison of Anteroposterior and Cross-Table Lateral Radiographs with Computed Tomography Scans. Goyal T; Paul S; Choudhury AK; Gupta T Clin Orthop Surg; 2021 Sep; 13(3):329-335. PubMed ID: 34484625 [TBL] [Abstract][Full Text] [Related]
19. Acetabular orientation variability and symmetry based on CT scans of adults. Lubovsky O; Peleg E; Joskowicz L; Liebergall M; Khoury A Int J Comput Assist Radiol Surg; 2010 Sep; 5(5):449-54. PubMed ID: 20680495 [TBL] [Abstract][Full Text] [Related]
20. A cadaver study validating CT assessment of acetabular component orientation: the Perth CT hip protocol. Arora V; Hannan R; Beaver R; Fletcher T; Harvie P Skeletal Radiol; 2017 Feb; 46(2):177-183. PubMed ID: 27826701 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]