These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 20813628)

  • 1. Independent component analysis for auditory evoked potentials and cochlear implant artifact estimation.
    Castañeda-Villa N; James CJ
    IEEE Trans Biomed Eng; 2011 Feb; 58(2):348-54. PubMed ID: 20813628
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Semi-automatic attenuation of cochlear implant artifacts for the evaluation of late auditory evoked potentials.
    Viola FC; De Vos M; Hine J; Sandmann P; Bleeck S; Eyles J; Debener S
    Hear Res; 2012 Feb; 284(1-2):6-15. PubMed ID: 22234161
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The selection of optimal ICA algorithm parameters for robust AEP component estimates using 3 popular ICA algorithms.
    Castañeda-Villa N; James CJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5216-9. PubMed ID: 19163893
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Minimization of cochlear implant stimulus artifact in cortical auditory evoked potentials.
    Gilley PM; Sharma A; Dorman M; Finley CC; Panch AS; Martin K
    Clin Neurophysiol; 2006 Aug; 117(8):1772-82. PubMed ID: 16807102
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of the cochlear implant artifact correction tool for auditory electrophysiology.
    Miller S; Zhang Y
    Neurosci Lett; 2014 Aug; 577():51-5. PubMed ID: 24946164
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Beamformer suppression of cochlear implant artifacts in an electroencephalography dataset.
    Wong DD; Gordon KA
    IEEE Trans Biomed Eng; 2009 Dec; 56(12):2851-7. PubMed ID: 19695980
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cochlear implant artifact attenuation in late auditory evoked potentials: a single channel approach.
    Mc Laughlin M; Lopez Valdes A; Reilly RB; Zeng FG
    Hear Res; 2013 Aug; 302():84-95. PubMed ID: 23727626
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automatic correction of artifact from single-trial event-related potentials by blind source separation using second order statistics only.
    Ting KH; Fung PC; Chang CQ; Chan FH
    Med Eng Phys; 2006 Oct; 28(8):780-94. PubMed ID: 16406675
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel method for device-related electroencephalography artifact suppression to explore cochlear implant-related cortical changes in single-sided deafness.
    Kim K; Punte AK; Mertens G; Van de Heyning P; Park KJ; Choi H; Choi JW; Song JJ
    J Neurosci Methods; 2015 Nov; 255():22-8. PubMed ID: 26231621
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Minimization of cochlear implant artifact in cortical auditory evoked potentials in children.
    Bakhos D; Roux S; Robier A; Bonnet-Brilhault F; Lescanne E; Bruneau N
    Int J Pediatr Otorhinolaryngol; 2012 Nov; 76(11):1627-32. PubMed ID: 22910837
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Recording and analysis of electrically evoked compound action potentials (ECAPs) with MED-EL cochlear implants and different artifact reduction strategies in Matlab.
    Bahmer A; Peter O; Baumann U
    J Neurosci Methods; 2010 Aug; 191(1):66-74. PubMed ID: 20558202
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Independent component approach to the analysis of EEG and MEG recordings.
    Vigário R; Särelä J; Jousmäki V; Hämäläinen M; Oja E
    IEEE Trans Biomed Eng; 2000 May; 47(5):589-93. PubMed ID: 10851802
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Source localization of auditory evoked potentials after cochlear implantation.
    Debener S; Hine J; Bleeck S; Eyles J
    Psychophysiology; 2008 Jan; 45(1):20-4. PubMed ID: 17910729
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Auditory steady state responses and cochlear implants: Modeling the artifact-response mixture in the perspective of denoising.
    Mina F; Attina V; Duroc Y; Veuillet E; Truy E; Thai-Van H
    PLoS One; 2017; 12(3):e0174462. PubMed ID: 28350887
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Independent component analysis for cochlear implant artifacts attenuation from electrically evoked auditory steady-state response measurements.
    Deprez H; Gransier R; Hofmann M; van Wieringen A; Wouters J; Moonen M
    J Neural Eng; 2018 Feb; 15(1):016006. PubMed ID: 29211684
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of evoked potentials to dyadic tones after cochlear implantation.
    Sandmann P; Eichele T; Buechler M; Debener S; Jäncke L; Dillier N; Hugdahl K; Meyer M
    Brain; 2009 Jul; 132(Pt 7):1967-79. PubMed ID: 19293240
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A system for automatic artifact removal in ictal scalp EEG based on independent component analysis and Bayesian classification.
    LeVan P; Urrestarazu E; Gotman J
    Clin Neurophysiol; 2006 Apr; 117(4):912-27. PubMed ID: 16458594
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A New Method to Test the Efficiency of Cochlear Implant Artifacts Removal From Auditory Evoked Potentials.
    Attina V; Mina F; Stahl P; Duroc Y; Veuillet E; Truy E; Thai-Van H
    IEEE Trans Neural Syst Rehabil Eng; 2017 Dec; 25(12):2453-2460. PubMed ID: 28692981
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sorted averaging--application to auditory event-related responses.
    Rahne T; von Specht H; Mühler R
    J Neurosci Methods; 2008 Jul; 172(1):74-8. PubMed ID: 18499265
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Semi-automatic identification of independent components representing EEG artifact.
    Viola FC; Thorne J; Edmonds B; Schneider T; Eichele T; Debener S
    Clin Neurophysiol; 2009 May; 120(5):868-77. PubMed ID: 19345611
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.