These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 20815473)

  • 1. A hybrid scheme for bore design optimization of a brass instrument.
    Noreland JO; Udawalpola MR; Berggren OM
    J Acoust Soc Am; 2010 Sep; 128(3):1391-400. PubMed ID: 20815473
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multiobjective muffler shape optimization with hybrid acoustics modeling.
    Airaksinen T; Heikkola E
    J Acoust Soc Am; 2011 Sep; 130(3):1359-69. PubMed ID: 21895077
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite difference time domain simulation for the brass instrument bore.
    Bilbao S; Chick J
    J Acoust Soc Am; 2013 Nov; 134(5):3860-71. PubMed ID: 24180795
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Model-based optimization of ultrasonic transducers.
    Heikkola E; Laitinen M
    Ultrason Sonochem; 2005 Jan; 12(1-2):53-7. PubMed ID: 15474952
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of wall vibrations on the sound of brass wind instruments.
    Kausel W; Zietlow DW; Moore TR
    J Acoust Soc Am; 2010 Nov; 128(5):3161-74. PubMed ID: 21110611
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An improved quasi-static finite-difference scheme for induced field evaluation based on the biconjugate gradient method.
    Wang H; Liu F; Trakic A; Crozier S
    IEEE Trans Biomed Eng; 2008 Jul; 55(7):1800-8. PubMed ID: 18595798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multiobjective optimization of tibial locking screw design using a genetic algorithm: Evaluation of mechanical performance.
    Hsu CC; Chao CK; Wang JL; Lin J
    J Orthop Res; 2006 May; 24(5):908-16. PubMed ID: 16528743
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design of monolimb using finite element modelling and statistics-based Taguchi method.
    Lee WC; Zhang M
    Clin Biomech (Bristol, Avon); 2005 Aug; 20(7):759-66. PubMed ID: 15963612
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Topology optimization of a novel stent platform with drug reservoirs.
    Wu W; Yang DZ; Huang YY; Qi M; Wang WQ
    Med Eng Phys; 2008 Nov; 30(9):1177-85. PubMed ID: 18407779
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analytical design of iron golf club heads.
    Hartzell TA; Nesbit SM
    J Sports Sci; 1996 Aug; 14(4):311-9. PubMed ID: 8887210
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The direct field boundary impedance of two-dimensional periodic structures with application to high frequency vibration prediction.
    Langley RS; Cotoni V
    J Acoust Soc Am; 2010 Apr; 127(4):2118-28. PubMed ID: 20369993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. On the finite element modelling of balloon-expandable stents.
    Ju F; Xia Z; Sasaki K
    J Mech Behav Biomed Mater; 2008 Jan; 1(1):86-95. PubMed ID: 19627774
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Finite element modelling of medical devices.
    Prendergast PJ; Lally C; Lennon AB
    Med Eng Phys; 2009 May; 31(4):419. PubMed ID: 19329044
    [No Abstract]   [Full Text] [Related]  

  • 14. Realistic finite element-based stent design: the impact of balloon folding.
    De Beule M; Mortier P; Carlier SG; Verhegghe B; Van Impe R; Verdonck P
    J Biomech; 2008; 41(2):383-9. PubMed ID: 17920068
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sound simulation-based design optimization of brass wind instruments.
    Tournemenne R; Petiot JF; Talgorn B; Gilbert J; Kokkolaras M
    J Acoust Soc Am; 2019 Jun; 145(6):3795. PubMed ID: 31255147
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Model optimization of orthotropic distributed-mode loudspeaker using attached masses.
    Lu G; Shen Y
    J Acoust Soc Am; 2009 Nov; 126(5):2294-300. PubMed ID: 19894811
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Downhill simplex algorithm based approach to holey fiber design for tunable fiber parametric wavelength converters.
    Cui S; Liu D; Yu S; Huang B; Ke C; Zhang M; Liu C
    Opt Express; 2010 May; 18(10):9831-9. PubMed ID: 20588832
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computational modeling and prototyping of a pediatric airway management instrument.
    Gonzalez-Cota A; Kruger GH; Raghavan P; Reynolds PI
    Anesth Analg; 2010 Sep; 111(3):649-52. PubMed ID: 20581164
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Structural acoustic control of plates with variable boundary conditions: design methodology.
    Sprofera JD; Cabell RH; Gibbs GP; Clark RL
    J Acoust Soc Am; 2007 Jul; 122(1):271-9. PubMed ID: 17614487
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tapering fibers with complex shape.
    Pricking S; Giessen H
    Opt Express; 2010 Feb; 18(4):3426-37. PubMed ID: 20389352
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.