  • 1. Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and trans-thoracic echocardiography in patients referred for transcatheter aortic valve implantation.
    Tzikas A; Schultz CJ; Piazza N; Moelker A; Van Mieghem NM; Nuis RJ; van Geuns RJ; Geleijnse ML; Serruys PW; de Jaegere PP
    Catheter Cardiovasc Interv; 2011 May; 77(6):868-75. PubMed ID: 20824762
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation.
    Altiok E; Koos R; Schröder J; Brehmer K; Hamada S; Becker M; Mahnken AH; Almalla M; Dohmen G; Autschbach R; Marx N; Hoffmann R
    Heart; 2011 Oct; 97(19):1578-84. PubMed ID: 21700756
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prosthesis sizing for transcatheter aortic valve implantation--comparison of three dimensional transesophageal echocardiography with multislice computed tomography.
    Husser O; Holzamer A; Resch M; Endemann DH; Nunez J; Bodi V; Schmid C; Riegger GA; Gössmann H; Hamer O; Stroszczynski C; Luchner A; Hilker M; Hengstenberg C
    Int J Cardiol; 2013 Oct; 168(4):3431-8. PubMed ID: 23688431
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography.
    Ng AC; Delgado V; van der Kley F; Shanks M; van de Veire NR; Bertini M; Nucifora G; van Bommel RJ; Tops LF; de Weger A; Tavilla G; de Roos A; Kroft LJ; Leung DY; Schuijf J; Schalij MJ; Bax JJ
    Circ Cardiovasc Imaging; 2010 Jan; 3(1):94-102. PubMed ID: 19920027
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Aortic annulus evaluation in transcatheter aortic valve implantation.
    Hutter A; Opitz A; Bleiziffer S; Ruge H; Hettich I; Mazzitelli D; Will A; Tassani P; Bauernschmitt R; Lange R
    Catheter Cardiovasc Interv; 2010 Dec; 76(7):1009-19. PubMed ID: 20518012
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation.
    Watanabe Y; Morice MC; Bouvier E; Leong T; Hayashida K; Lefèvre T; Hovasse T; Romano M; Chevalier B; Donzeau-Gouge P; Farge A; Cormier B; Garot P
    JACC Cardiovasc Interv; 2013 Sep; 6(9):955-64. PubMed ID: 23954060
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation.
    Messika-Zeitoun D; Serfaty JM; Brochet E; Ducrocq G; Lepage L; Detaint D; Hyafil F; Himbert D; Pasi N; Laissy JP; Iung B; Vahanian A
    J Am Coll Cardiol; 2010 Jan; 55(3):186-94. PubMed ID: 20117398
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement.
    Stortecky S; Heg D; Gloekler S; Wenaweser P; Windecker S; Buellesfeld L
    EuroIntervention; 2014 Jul; 10(3):339-46. PubMed ID: 24273249
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation.
    Husser O; Rauch S; Endemann DH; Resch M; Nunez J; Bodi V; Hilker M; Schmid C; Riegger GA; Luchner A; Hengstenberg C
    Catheter Cardiovasc Interv; 2012 Nov; 80(6):956-63. PubMed ID: 22419651
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Role of multislice computed tomography in transcatheter aortic valve replacement.
    Wood DA; Tops LF; Mayo JR; Pasupati S; Schalij MJ; Humphries K; Lee M; Al Ali A; Munt B; Moss R; Thompson CR; Bax JJ; Webb JG
    Am J Cardiol; 2009 May; 103(9):1295-301. PubMed ID: 19406275
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis.
    Schultz C; Rossi A; van Mieghem N; van der Boon R; Papadopoulou SL; van Domburg R; Moelker A; Mollet N; Krestin G; van Geuns RJ; Nieman K; de Feyter P; Serruys PW; de Jaegere P
    EuroIntervention; 2011 Sep; 7(5):564-72. PubMed ID: 21930460
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method.
    Blanke P; Siepe M; Reinöhl J; Zehender M; Beyersdorf F; Schlensak C; Langer M; Pache G
    Eur J Cardiothorac Surg; 2010 Dec; 38(6):750-8. PubMed ID: 20472458
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis.
    Schultz CJ; Tzikas A; Moelker A; Rossi A; Nuis RJ; Geleijnse MM; van Mieghem N; Krestin GP; de Feyter P; Serruys PW; de Jaegere PP
    Catheter Cardiovasc Interv; 2011 Sep; 78(3):446-55. PubMed ID: 21793166
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Comparison of aortic annular diameter defined by different measurement mordalities before transcatheter aortic valve implantation].
    Qi RX; You XD; Pu ZX; Yang Q; Huang ZX; Zhou LM; Huang PT
    Zhonghua Xin Xue Guan Bing Za Zhi; 2017 May; 45(5):409-414. PubMed ID: 28511326
    [No Abstract]   [Full Text] [Related]  

  • 15. Evaluation of aortic root for definition of prosthesis size by magnetic resonance imaging and cardiac computed tomography: implications for transcatheter aortic valve implantation.
    Koos R; Altiok E; Mahnken AH; Neizel M; Dohmen G; Marx N; Kühl H; Hoffmann R
    Int J Cardiol; 2012 Jul; 158(3):353-8. PubMed ID: 21315460
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation.
    Bernhardt P; Rodewald C; Seeger J; Gonska B; Buckert D; Radermacher M; Hombach V; Rottbauer W; Wöhrle J
    Clin Res Cardiol; 2016 Mar; 105(3):273-8. PubMed ID: 26395021
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation.
    Sherif MA; Ince H; Maniuc O; Reiter T; Voelker W; Ertl G; Öner A
    BMC Cardiovasc Disord; 2015 Dec; 15():181. PubMed ID: 26715337
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis.
    Mizia-Stec K; Pysz P; Jasiński M; Adamczyk T; Drzewiecka-Gerber A; Chmiel A; Krejca M; Bochenek A; Woś S; Sosnowski M; Gąsior Z; Trusz-Gluza M; Tendera M
    Int J Cardiovasc Imaging; 2012 Feb; 28(2):343-52. PubMed ID: 21279693
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimal prosthesis sizing in transcatheter aortic valve implantation by exclusive use of three-dimensional transoesophageal echocardiography.
    Kretzschmar D; Lauten A; Goebel B; Doenst T; Poerner TC; Ferrari M; Figulla HR; Hamadanchi A
    Clin Physiol Funct Imaging; 2016 Mar; 36(2):99-105. PubMed ID: 25316588
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement.
    Tops LF; Wood DA; Delgado V; Schuijf JD; Mayo JR; Pasupati S; Lamers FP; van der Wall EE; Schalij MJ; Webb JG; Bax JJ
    JACC Cardiovasc Imaging; 2008 May; 1(3):321-30. PubMed ID: 19356444
    [TBL] [Abstract][Full Text] [Related]  