1. Flow resistance, work of breathing of humidifiers, and endotracheal tubes in the hyperbaric chamber.
Arieli R; Daskalovic Y; Ertracht O; Arieli Y; Adir Y; Abramovich A; Halpern P
Am J Emerg Med; 2011 Sep; 29(7):725-30. PubMed ID: 20825878
[TBL] [Abstract][Full Text] [Related]
2. Estimation of tracheal pressure and imposed expiratory work of breathing by the endotracheal tube, heat and moisture exchanger, and ventilator during mechanical ventilation.
Uchiyama A; Yoshida T; Yamanaka H; Fujino Y
Respir Care; 2013 Jul; 58(7):1157-69. PubMed ID: 23232731
[TBL] [Abstract][Full Text] [Related]
3. Potential inadequacy of automatic tube compensation to decrease inspiratory work load after at least 48 hours of endotracheal tube use in the clinical setting.
Oto J; Imanaka H; Nakataki E; Ono R; Nishimura M
Respir Care; 2012 May; 57(5):697-703. PubMed ID: 22153219
[TBL] [Abstract][Full Text] [Related]
4. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
[TBL] [Abstract][Full Text] [Related]
5. The impact of heat and moisture exchanging humidifiers on work of breathing.
Johnson PA; Raper RF; Fisher MM
Anaesth Intensive Care; 1995 Dec; 23(6):697-701. PubMed ID: 8669603
[TBL] [Abstract][Full Text] [Related]
6. Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support.
Fujino Y; Uchiyama A; Mashimo T; Nishimura M
Respir Care; 2003 Jan; 48(1):38-45. PubMed ID: 12556260
[TBL] [Abstract][Full Text] [Related]
7. Devices used to humidify respired gases.
Rathgeber J
Respir Care Clin N Am; 2006 Jun; 12(2):165-82. PubMed ID: 16828689
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of resistance in 8 different heat-and-moisture exchangers: effects of saturation and flow rate/profile.
Lucato JJ; Tucci MR; Schettino GP; Adams AB; Fu C; Forti G; de Carvalho CR; de Souza R
Respir Care; 2005 May; 50(5):636-43. PubMed ID: 15871758
[TBL] [Abstract][Full Text] [Related]
9. Intratracheal pressure: a more accurate reflection of pulmonary airway pressure in pediatric patients with respiratory failure.
Dela Cruz RH; Banner MJ; Weldon BC
Pediatr Crit Care Med; 2005 Mar; 6(2):175-81. PubMed ID: 15730605
[TBL] [Abstract][Full Text] [Related]
10. Imposed work of breathing during high-frequency oscillatory ventilation: a bench study.
van Heerde M; van Genderingen HR; Leenhoven T; Roubik K; Plötz FB; Markhorst DG
Crit Care; 2006 Feb; 10(1):R23. PubMed ID: 16469130
[TBL] [Abstract][Full Text] [Related]
11. Effect of the humidification device on the work of breathing during noninvasive ventilation.
Lellouche F; Maggiore SM; Deye N; Taillé S; Pigeot J; Harf A; Brochard L
Intensive Care Med; 2002 Nov; 28(11):1582-9. PubMed ID: 12415444
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of work of breathing in spontaneously breathing animals during partial liquid ventilation.
Heulitt MJ; Holt SJ; Wilson S; Simpson P
Respir Care; 2002 Jan; 47(1):39-47. PubMed ID: 11749686
[TBL] [Abstract][Full Text] [Related]
13. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings.
Hentschel R; Buntzel J; Guttmann J; Schumann S
Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238
[TBL] [Abstract][Full Text] [Related]
14. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
Campbell RS; Davis K; Johannigman JA; Branson RD
Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
[TBL] [Abstract][Full Text] [Related]
15. Mechanical effects of airway humidification devices in difficult to wean patients.
Girault C; Breton L; Richard JC; Tamion F; Vandelet P; Aboab J; Leroy J; Bonmarchand G
Crit Care Med; 2003 May; 31(5):1306-11. PubMed ID: 12771595
[TBL] [Abstract][Full Text] [Related]
16. Resistive pressure of a condenser humidifier in mechanically ventilated patients.
Manthous CA; Schmidt GA
Crit Care Med; 1994 Nov; 22(11):1792-5. PubMed ID: 7956283
[TBL] [Abstract][Full Text] [Related]
17. The esophageal-tracheal combitube resistance and ventilatory pressures.
Gaitini LA; Vaida SJ; Mostafa S; Yanovski B; Ben-David B; Benumof JL
J Clin Anesth; 2005 Feb; 17(1):26-9. PubMed ID: 15721726
[TBL] [Abstract][Full Text] [Related]
18. Effect of heat and moisture exchanger (HME) positioning on inspiratory gas humidification.
Inui D; Oto J; Nishimura M
BMC Pulm Med; 2006 Aug; 6():19. PubMed ID: 16895607
[TBL] [Abstract][Full Text] [Related]
19. [Measurement of the humidity of inspired air in ventilated patients with various humidifer systems].
Christiansen S; Renzing K; Hirche H; Reidemeister JC
Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 May; 33(5):300-5. PubMed ID: 9645289
[TBL] [Abstract][Full Text] [Related]
20. Work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome: a comparison between volume and pressure-regulated breathing modes.
Kallet RH; Campbell AR; Dicker RA; Katz JA; Mackersie RC
Respir Care; 2005 Dec; 50(12):1623-31. PubMed ID: 16318643
[TBL] [Abstract][Full Text] [Related]