These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 20828006)

  • 1. [Detection of metal residue in aqueous solutions by electrolyte cathode atmospheric glow discharge emission spectroscopy].
    Zheng PC; Wang HM; Li JQ; Han HY; Xi XQ; Chu YN
    Guang Pu Xue Yu Guang Pu Fen Xi; 2010 Jul; 30(7):1948-51. PubMed ID: 20828006
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The improvement of the analytical performance of direct current atmospheric pressure glow discharge generated in contact with the small-sized liquid cathode after the addition of non-ionic surfactants to electrolyte solutions.
    Gręda K; Jamróz P; Pohl P
    Talanta; 2013 Apr; 108():74-82. PubMed ID: 23601872
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of trace heavy metals in environmental and biological samples by solution cathode glow discharge-atomic emission spectrometry and addition of ionic surfactants for improved sensitivity.
    Zhang Z; Wang Z; Li Q; Zou H; Shi Y
    Talanta; 2014 Feb; 119():613-9. PubMed ID: 24401463
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Detection of Lead in Water by Electrolyte Cathode Atmospheric Glow Discharge Emission Spectroscopy].
    Zheng PC; Zhang B; Wang JM; Wang XM; Liu HD; Yang R
    Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Jul; 35(7):2012-6. PubMed ID: 26717769
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of calcium and zinc in gluconates oral solution and blood samples by liquid cathode glow discharge-atomic emission spectrometry.
    Yu J; Zhang X; Lu Q; Wang X; Sun D; Wang Y; Yang W
    Talanta; 2017 Dec; 175():150-157. PubMed ID: 28841972
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In-situ generation of Ag, Cd, Hg, In, Pb, Tl and Zn volatile species by flowing liquid anode atmospheric pressure glow discharge operated in gaseous jet mode - Evaluation of excitation processes and analytical performance.
    Greda K; Gorska M; Welna M; Jamroz P; Pohl P
    Talanta; 2019 Jul; 199():107-115. PubMed ID: 30952233
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An atmospheric pressure glow discharge optical emission source for the direct sampling of liquid media.
    Marcus RK; Davis WC
    Anal Chem; 2001 Jul; 73(13):2903-10. PubMed ID: 11467534
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of liquid cathode glow discharge-atomic emission spectrometry for determination of copper and lead in ores samples.
    Yu J; Yang S; Lu Q; Sun D; Zheng J; Zhang X; Wang X; Yang W
    Talanta; 2017 Mar; 164():216-221. PubMed ID: 28107920
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Laser-excited atomic fluorescence in a pulsed hollow-cathode glow discharge.
    Glick M; Smith BW; Winefordner JD
    Anal Chem; 1990 Jan; 62(2):157-61. PubMed ID: 2310012
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-Sensitivity Determination of K, Ca, Na, and Mg in Salt Mines Samples by Atomic Emission Spectrometry with a Miniaturized Liquid Cathode Glow Discharge.
    Yu J; Zhang Z; Lu Q; Sun D; Zhu S; Zhang X; Wang X; Yang W
    J Anal Methods Chem; 2017; 2017():7105831. PubMed ID: 29238624
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enhancement of emission from indium in flowing liquid anode atmospheric pressure glow discharge using organic media.
    Greda K; Burhenn S; Pohl P; Franzke J
    Talanta; 2019 Nov; 204():304-309. PubMed ID: 31357298
    [TBL] [Abstract][Full Text] [Related]  

  • 12. On the coupling of hydride generation with atmospheric pressure glow discharge in contact with the flowing liquid cathode for the determination of arsenic, antimony and selenium with optical emission spectrometry.
    Greda K; Jamroz P; Jedryczko D; Pohl P
    Talanta; 2015 May; 137():11-7. PubMed ID: 25770600
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of Hg(2+) by on-line separation and pre-concentration with atmospheric-pressure solution-cathode glow discharge atomic emission spectrometry.
    Li Q; Zhang Z; Wang Z
    Anal Chim Acta; 2014 Oct; 845():7-14. PubMed ID: 25201266
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Direct optical emission spectroscopy of liquid analytes using an electrolyte as a cathode discharge source (ELCAD) integrated on a micro-fluidic chip.
    Jenkins G; Franzke J; Manz A
    Lab Chip; 2005 Jul; 5(7):711-8. PubMed ID: 15970963
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Liquid-interfaced oscillating glow discharge detector for a flowing liquid system.
    Herring CJ; Piepmeier EH
    Anal Chem; 1995 Mar; 67(5):878-84. PubMed ID: 7762824
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Surface oxidation of polyethylene using an atmospheric pressure glow discharge with liquid electrolyte cathode.
    Choi HS; Shikova TG; Titov VA; Rybkin VV
    J Colloid Interface Sci; 2006 Aug; 300(2):640-7. PubMed ID: 16690073
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On line vapor generation of osmium based on solution cathode glow discharge for the determination by ICP-OES.
    Zhu Z; Huang C; He Q; Xiao Q; Liu Z; Zhang S; Hu S
    Talanta; 2013 Mar; 106():133-6. PubMed ID: 23598105
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Compact glow discharge for the elemental analysis of aqueous samples.
    Webb MR; Andrade FJ; Hieftje GM
    Anal Chem; 2007 Oct; 79(20):7899-905. PubMed ID: 17824668
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-throughput elemental analysis of small aqueous samples by emission spectrometry with a compact, atmospheric-pressure solution-cathode glow discharge.
    Webb MR; Andrade FJ; Hieftje GM
    Anal Chem; 2007 Oct; 79(20):7807-12. PubMed ID: 17784731
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Determination of aqueous potassium and sodium ions with liquid-phase diaphragm glow discharge-atomic emission spectrometry].
    Liu YJ; Wang L
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Sep; 33(9):2570-3. PubMed ID: 24369674
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.