81 related articles for article (PubMed ID: 20828136)
1. Theory for inverse pulsing of the shutter grid in ion mobility spectrometry.
Spangler GE
Anal Chem; 2010 Oct; 82(19):8052-9. PubMed ID: 20828136
[TBL] [Abstract][Full Text] [Related]
2. Peak-peak repulsion in ion mobility spectrometry.
Ilbeigi V; Tabrizchi M
Anal Chem; 2012 Apr; 84(8):3669-75. PubMed ID: 22455316
[TBL] [Abstract][Full Text] [Related]
3. A study of the performance of an ion shutter for drift tubes in atmospheric pressure ion mobility spectrometry: computer models and experimental findings.
Tadjimukhamedov FK; Puton J; Stone JA; Eiceman GA
Rev Sci Instrum; 2009 Oct; 80(10):103103. PubMed ID: 19895050
[TBL] [Abstract][Full Text] [Related]
4. Inverse ion mobility spectrometry.
Tabrizchi M; Jazan E
Anal Chem; 2010 Jan; 82(2):746-50. PubMed ID: 20038156
[TBL] [Abstract][Full Text] [Related]
5. Programmable gate delayed ion mobility spectrometry-mass spectrometry: a study with low concentrations of dipropylene-glycol-monomethyl-ether in air.
Hill CA; Thomas CL
Analyst; 2005 Aug; 130(8):1155-61. PubMed ID: 16021214
[TBL] [Abstract][Full Text] [Related]
6. Bradbury-Nielsen-gate-grid structure for further enhancing the resolution of ion mobility spectrometry.
Du Y; Wang W; Li H
Anal Chem; 2012 Jul; 84(13):5700-7. PubMed ID: 22762264
[TBL] [Abstract][Full Text] [Related]
7. Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis.
Sysoev A; Adamov A; Viidanoja J; Ketola RA; Kostiainen R; Kotiaho T
Rapid Commun Mass Spectrom; 2004; 18(24):3131-9. PubMed ID: 15565719
[TBL] [Abstract][Full Text] [Related]
8. Direct analysis of pharmaceutical drug formulations using ion mobility spectrometry/quadrupole-time-of-flight mass spectrometry combined with desorption electrospray ionization.
Weston DJ; Bateman R; Wilson ID; Wood TR; Creaser CS
Anal Chem; 2005 Dec; 77(23):7572-80. PubMed ID: 16316164
[TBL] [Abstract][Full Text] [Related]
9. Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas.
Eiceman GA; Krylov EV; Krylova NS; Nazarov EG; Miller RA
Anal Chem; 2004 Sep; 76(17):4937-44. PubMed ID: 15373426
[TBL] [Abstract][Full Text] [Related]
10. [Ion mobility spectrometry for the isomeric volatile organic compounds].
Han HY; Jia XD; Huang GD; Wang HM; Li JQ; Jin SP; Jiang HH; Chu YN; Zhou SK
Guang Pu Xue Yu Guang Pu Fen Xi; 2007 Oct; 27(10):1925-8. PubMed ID: 18306763
[TBL] [Abstract][Full Text] [Related]
11. An approach to enhancing coverage of the urinary metabonome using liquid chromatography-ion mobility-mass spectrometry.
Harry EL; Weston DJ; Bristow AW; Wilson ID; Creaser CS
J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Aug; 871(2):357-61. PubMed ID: 18502703
[TBL] [Abstract][Full Text] [Related]
12. A comparison of the ion chemistry for mono-substituted toluenes and anilines by three methods of atmospheric pressure ionization with ion mobility spectrometry.
Borsdorf H; Neitsch K; Eiceman GA; Stone JA
Talanta; 2009 Jun; 78(4-5):1464-75. PubMed ID: 19362218
[TBL] [Abstract][Full Text] [Related]
13. Characterization of a distributed plasma ionization source (DPIS) for ion mobility spectrometry and mass spectrometry.
Waltman MJ; Dwivedi P; Hill HH; Blanchard WC; Ewing RG
Talanta; 2008 Oct; 77(1):249-55. PubMed ID: 18804628
[TBL] [Abstract][Full Text] [Related]
14. A novel surface ionization source for ion mobility spectrometer.
Hui-yong G; Xiu-li H; Xiao-guang G; Jian J; Jian-ping L
Anal Chim Acta; 2007 Mar; 587(1):137-41. PubMed ID: 17386765
[TBL] [Abstract][Full Text] [Related]
15. Theoretical and experimental study of the achievable separation power in resistive-glass atmospheric pressure ion mobility spectrometry.
Kwasnik M; Fernández FM
Rapid Commun Mass Spectrom; 2010 Jul; 24(13):1911-8. PubMed ID: 20533321
[TBL] [Abstract][Full Text] [Related]
16. Radial stratification of ions as a function of mass to charge ratio in collisional cooling radio frequency multipoles used as ion guides or ion traps.
Tolmachev AV; Udseth HR; Smith RD
Rapid Commun Mass Spectrom; 2000; 14(20):1907-13. PubMed ID: 11013419
[TBL] [Abstract][Full Text] [Related]
17. Characterization of gas-phase molecular interactions on differential mobility ion behavior utilizing an electrospray ionization-differential mobility-mass spectrometer system.
Levin DS; Vouros P; Miller RA; Nazarov EG; Morris JC
Anal Chem; 2006 Jan; 78(1):96-106. PubMed ID: 16383315
[TBL] [Abstract][Full Text] [Related]
18. Achieving high gating performance for ion mobility spectrometry by manipulating ion swarm spatiotemporal behaviors in the vicinity of ion shutter.
Chen H; Chen C; Li M; Wang W; Jiang D; Li H
Anal Chim Acta; 2019 Apr; 1052():96-104. PubMed ID: 30685046
[TBL] [Abstract][Full Text] [Related]
19. [Discharge ion mobility spectrometry of ketonic organic compounds].
Huang GD; Han HY; Jia XD; Jin SP; Li JQ; Wang HM; Tang XS; Jiang HH; Chu YN; Zhou SK
Guang Pu Xue Yu Guang Pu Fen Xi; 2007 May; 27(5):833-6. PubMed ID: 17655083
[TBL] [Abstract][Full Text] [Related]
20. Rapid separation and quantitative analysis of peptides using a new nanoelectrospray- differential mobility spectrometer-mass spectrometer system.
Levin DS; Miller RA; Nazarov EG; Vouros P
Anal Chem; 2006 Aug; 78(15):5443-52. PubMed ID: 16878881
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]