BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

284 related articles for article (PubMed ID: 20828746)

  • 1. Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.
    Tuzun E; Rutten M; Dat M; van de Vosse F; Kadipasaoglu C; de Mol B
    J Surg Res; 2011 Dec; 171(2):443-7. PubMed ID: 20828746
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of pump rotation speed on hemodynamics and myocardial oxygen metabolism in left ventricular assist device support with aortic valve regurgitation.
    Iizuka K; Nishinaka T; Takewa Y; Yamazaki K; Tatsumi E
    J Artif Organs; 2017 Sep; 20(3):194-199. PubMed ID: 28429120
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Aortic Valve Function Under Support of a Left Ventricular Assist Device: Continuous vs. Dynamic Speed Support.
    Bozkurt S; van de Vosse FN; Rutten MC
    Ann Biomed Eng; 2015 Aug; 43(8):1727-37. PubMed ID: 25480480
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of aortic valve pressure overload and leaflet functions in an ex vivo beating heart loaded with a continuous flow cardiac assist device.
    Tuzun E; Pennings K; van Tuijl S; de Hart J; Stijnen M; van de Vosse F; de Mol B; Rutten M
    Eur J Cardiothorac Surg; 2014 Feb; 45(2):377-83. PubMed ID: 23818568
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Left ventricular assist device weaning: hemodynamic response and relationship to stroke volume and rate reduction protocols.
    Slaughter MS; Sobieski MA; Koenig SC; Pappas PS; Tatooles AJ; Silver MA
    ASAIO J; 2006; 52(3):228-33. PubMed ID: 16760709
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computational fluid dynamic study of hemodynamic effects on aortic root blood flow of systematically varied left ventricular assist device graft anastomosis design.
    Callington A; Long Q; Mohite P; Simon A; Mittal TK
    J Thorac Cardiovasc Surg; 2015 Sep; 150(3):696-704. PubMed ID: 26092505
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Programmed Speed Reduction Enables Aortic Valve Opening and Increased Pulsatility in the LVAD-Assisted Heart.
    Tolpen S; Janmaat J; Reider C; Kallel F; Farrar D; May-Newman K
    ASAIO J; 2015; 61(5):540-7. PubMed ID: 25961849
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous transcatheter aortic valve closure successfully treats left ventricular assist device-associated aortic insufficiency and improves cardiac hemodynamics.
    Parikh KS; Mehrotra AK; Russo MJ; Lang RM; Anderson A; Jeevanandam V; Freed BH; Paul JD; Karol J; Nathan S; Shah AP
    JACC Cardiovasc Interv; 2013 Jan; 6(1):84-9. PubMed ID: 23347865
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of aortic valve incompetence on the hemodynamics of a continuous flow ventricular assist device in a mock circulation.
    Zamarripa Garcia MA; Enriquez LA; Dembitsky W; May-Newman K
    ASAIO J; 2008; 54(3):237-44. PubMed ID: 18496272
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ventricular assist device outflow-graft site: effect on myocardial blood flow.
    Tuzun E; Narin C; Gregoric ID; Cohn WE; Frazier OH
    J Surg Res; 2011 Nov; 171(1):71-5. PubMed ID: 20605602
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanics of the aortic valve in the continuous flow VAD-assisted heart.
    May-Newman K; Enriquez-Almaguer L; Posuwattanakul P; Dembitsky W
    ASAIO J; 2010; 56(4):301-8. PubMed ID: 20559132
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design and control of the atrio-aortic left ventricular assist device based on O2 consumption.
    Drzewiecki GM; Pilla JJ; Welkowitz W
    IEEE Trans Biomed Eng; 1990 Feb; 37(2):128-37. PubMed ID: 2312137
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device: constant versus increasing pump speed: a pilot study.
    Brassard P; Jensen AS; Nordsborg N; Gustafsson F; Møller JE; Hassager C; Boesgaard S; Hansen PB; Olsen PS; Sander K; Secher NH; Madsen PL
    Circ Heart Fail; 2011 Sep; 4(5):554-60. PubMed ID: 21765126
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro evaluation of aortic insufficiency with a rotary left ventricular assist device.
    Gregory SD; Stevens MC; Wu E; Fraser JF; Timms D
    Artif Organs; 2013 Sep; 37(9):802-9. PubMed ID: 23901787
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effective ventricular unloading by left ventricular assist device varies with stage of heart failure: cardiac simulator study.
    Jhun CS; Reibson JD; Cysyk JP
    ASAIO J; 2011; 57(5):407-13. PubMed ID: 21817896
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accurate Quantification Methods for Aortic Insufficiency Severity in Patients With LVAD: Role of Diastolic Flow Acceleration and Systolic-to-Diastolic Peak Velocity Ratio of Outflow Cannula.
    Grinstein J; Kruse E; Sayer G; Fedson S; Kim GH; Jorde UP; Juricek C; Ota T; Jeevanandam V; Lang RM; Uriel N
    JACC Cardiovasc Imaging; 2016 Jun; 9(6):641-51. PubMed ID: 26684975
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The hemodynamic effects of mechanical prosthetic valve type and orientation on fluid mechanical energy loss and pressure drop in in vitro models of ventricular hypertrophy.
    Travis BR; Heinrich RS; Ensley AE; Gibson DE; Hashim S; Yoganathan AP
    J Heart Valve Dis; 1998 May; 7(3):345-54. PubMed ID: 9651851
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acute in vivo evaluation of an implantable continuous flow biventricular assist system.
    Saeed D; Ootaki Y; Ootaki C; Akiyama M; Horai T; Catanese J; Fumoto H; Dessoffy R; Massiello AL; Horvath DJ; Zhou Q; Chen JF; Benefit S; Golding LA; Fukamachi K
    ASAIO J; 2008; 54(1):20-4. PubMed ID: 18204311
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Left ventricular assist device malfunction: a systematic approach to diagnosis.
    Horton SC; Khodaverdian R; Powers A; Revenaugh J; Renlund DG; Moore SA; Rasmusson B; Nelson KE; Long JW
    J Am Coll Cardiol; 2004 May; 43(9):1574-83. PubMed ID: 15120814
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Is native aortic valve commissural fusion in patients with long-term left ventricular assist devices associated with clinically important aortic insufficiency?
    Letsou GV; Connelly JH; Delgado RM; Myers TJ; Gregoric ID; Smart FW; Frazier OH
    J Heart Lung Transplant; 2006 Apr; 25(4):395-9. PubMed ID: 16563967
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.