159 related articles for article (PubMed ID: 20831078)
1. Evaluation of MatriXX for IMRT and VMAT dose verifications in peripheral dose regions.
Han Z; Ng SK; Bhagwat MS; Lyatskaya Y; Zygmanski P
Med Phys; 2010 Jul; 37(7):3704-14. PubMed ID: 20831078
[TBL] [Abstract][Full Text] [Related]
2. An oscillating sweeping gap test for VMAT quality assurance.
Bhagwat MS; Han Z; Ng SK; Zygmanski P
Phys Med Biol; 2010 Sep; 55(17):5029-44. PubMed ID: 20702923
[TBL] [Abstract][Full Text] [Related]
3. Angular dependence correction of MatriXX and its application to composite dose verification.
Shimohigashi Y; Araki F; Tominaga H; Sakata J; Kawasaki K; Kanetake N; Iwashita Y; Yoshimura S; Kawakami T; Ishihara T; Okuda T; Kogo K
J Appl Clin Med Phys; 2012 Sep; 13(5):3856. PubMed ID: 22955651
[TBL] [Abstract][Full Text] [Related]
4. Characterization and clinical evaluation of a novel 2D detector array for conventional and flattening filter free (FFF) IMRT pre-treatment verification.
Sekar Y; Thoelking J; Eckl M; Kalichava I; Sihono DSK; Lohr F; Wenz F; Wertz H
Z Med Phys; 2018 Apr; 28(2):134-141. PubMed ID: 29030203
[TBL] [Abstract][Full Text] [Related]
5. Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT.
Nelms BE; Opp D; Zhang G; Moros E; Feygelman V
Med Phys; 2014 Jun; 41(6):061704. PubMed ID: 24877799
[TBL] [Abstract][Full Text] [Related]
6. Angular dose dependence of Matrixx TM and its calibration.
Wolfsberger LD; Wagar M; Nitsch P; Bhagwat MS; Zygmanski P
J Appl Clin Med Phys; 2010 Jan; 11(1):3057. PubMed ID: 20160692
[TBL] [Abstract][Full Text] [Related]
7. IMAT-SIM: a new method for the clinical dosimetry of intensity-modulated arc therapy (IMAT).
Iori M; Cagni E; Nahum AE; Borasi G
Med Phys; 2007 Jul; 34(7):2759-73. PubMed ID: 17821983
[TBL] [Abstract][Full Text] [Related]
8. Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I'mRT MatriXX--a feasibility study.
Dobler B; Streck N; Klein E; Loeschel R; Haertl P; Koelbl O
Phys Med Biol; 2010 Jan; 55(2):N39-55. PubMed ID: 20023326
[TBL] [Abstract][Full Text] [Related]
9. A synthetic diamond diode in volumetric modulated arc therapy dosimetry.
Zani M; Bucciolini M; Casati M; Talamonti C; Marinelli M; Prestopino G; Tonnetti A; Verona-Rinati G
Med Phys; 2013 Sep; 40(9):092103. PubMed ID: 24007172
[TBL] [Abstract][Full Text] [Related]
10. The inter- and intrafraction reproducibilities of three common IMRT delivery techniques.
Buckey CR; Stathakis S; Papanikolaou N
Med Phys; 2010 Sep; 37(9):4854-60. PubMed ID: 20964202
[TBL] [Abstract][Full Text] [Related]
11. Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance.
Yewondwossen M
Med Dosim; 2012; 37(3):250-6. PubMed ID: 22189031
[TBL] [Abstract][Full Text] [Related]
12. Investigation of pulsed IMRT and VMAT for re-irradiation treatments: dosimetric and delivery feasibilities.
Lin MH; Price RA; Li J; Kang S; Li J; Ma CM
Phys Med Biol; 2013 Nov; 58(22):8179-96. PubMed ID: 24200917
[TBL] [Abstract][Full Text] [Related]
13. Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.
Létourneau D; Publicover J; Kozelka J; Moseley DJ; Jaffray DA
Med Phys; 2009 May; 36(5):1813-21. PubMed ID: 19544800
[TBL] [Abstract][Full Text] [Related]
14. Peripheral doses from pediatric IMRT.
Klein EE; Maserang B; Wood R; Mansur D
Med Phys; 2006 Jul; 33(7):2525-31. PubMed ID: 16898456
[TBL] [Abstract][Full Text] [Related]
15. Optimizing the accuracy of a helical diode array dosimeter: a comprehensive calibration methodology coupled with a novel virtual inclinometer.
Kozelka J; Robinson J; Nelms B; Zhang G; Savitskij D; Feygelman V
Med Phys; 2011 Sep; 38(9):5021-32. PubMed ID: 21978046
[TBL] [Abstract][Full Text] [Related]
16. Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.
Togno M; Wilkens JJ; Menichelli D; Oechsner M; Perez-Andujar A; Morin O
Med Phys; 2016 May; 43(5):2283. PubMed ID: 27147340
[TBL] [Abstract][Full Text] [Related]
17. Characterization of a novel two dimensional diode array the "magic plate" as a radiation detector for radiation therapy treatment.
Wong JH; Fuduli I; Carolan M; Petasecca M; Lerch ML; Perevertaylo VL; Metcalfe P; Rosenfeld AB
Med Phys; 2012 May; 39(5):2544-58. PubMed ID: 22559625
[TBL] [Abstract][Full Text] [Related]
18. Evaluation and improvement of angular response for a commercial 2D detector array for patient-specific QA.
Wang S; Zheng Y
J Appl Clin Med Phys; 2023 Sep; 24(9):e14106. PubMed ID: 37593989
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric effects of multileaf collimator leaf width on intensity-modulated radiotherapy for head and neck cancer.
Hong CS; Ju SG; Kim M; Kim JI; Kim JM; Suh TS; Han Y; Ahn YC; Choi DH; Nam H; Park HC
Med Phys; 2014 Feb; 41(2):021712. PubMed ID: 24506603
[TBL] [Abstract][Full Text] [Related]
20. 2D lag and signal nonlinearity correction in an amorphous silicon EPID and their impact on pretreatment dosimetric verification.
Warkentin B; Rathee S; Steciw S
Med Phys; 2012 Nov; 39(11):6597-608. PubMed ID: 23127054
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]