These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

66 related articles for article (PubMed ID: 2083807)

  • 1. [Comparison of 6 and 8 French catheters for arterial catheterization and coronarography: prospects of the development of coronarography in ambulatory care].
    Campolo L; Leonardi G; Millan G; Formentini A; Salvadè P; De Biase AM; Roghi A; Danzi G; Silva P
    G Ital Cardiol; 1990 Dec; 20(12):1118-24. PubMed ID: 2083807
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Outpatient coronary angiography with 4 French catheters.
    Burger W; Gärtner J; Kneissl GD; Rothe WK; Hartmann A
    J Invasive Cardiol; 1999 Feb; 11(2):66-9. PubMed ID: 10745483
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Randomized comparison of 4F and 6F catheters for diagnostic coronary angiographies via the femoral approach].
    Ballout J; André F; Cottin Y; Laurent G; Eicher JC; Bulté C; Zeller M; Jirina K; Louis P; Wolf JE
    Arch Mal Coeur Vaiss; 2000 Jan; 93(1):35-9. PubMed ID: 11227716
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Coronary angioplasty through 6 French guiding catheters].
    Morís de la Tassa C; Rodríguez Lambert JL; Santos AE; Villa RB; Rodríguez Blanco VM; Barriales Alvarez V; Llosa AC
    Rev Esp Cardiol; 1996 Feb; 49(2):124-9. PubMed ID: 8948722
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Heart catheterization via the femoral artery with a 4 French and mobilization at 2 hours].
    Conte L; Dutto M; Dutto S; Giachello G; Lice G; Tomatis M; Russo P; Dellavalle A; Ribichini F; Steffenino G
    G Ital Cardiol; 1999 May; 29(5):529-32. PubMed ID: 10367220
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of 4 and 6 French catheters for coronary angiography: real-world modeling.
    Durst R; Lotan C; Nassar H; Gotsman M; Mor E; Varshitzki B; Greganski P; Jabara R; Admon D; Meerkin D; Mosseri M
    Isr Med Assoc J; 2007 Apr; 9(4):290-3. PubMed ID: 17491224
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Percutaneous femoral artery coronary arteriography. 300 consecutive cases with French 5 catheters].
    Favereau X; Corcos T; Duc P; Quennevat P; Benarroch E; Desoutter P
    Arch Mal Coeur Vaiss; 1988 Jul; 81(7):903-6. PubMed ID: 3142388
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Percutaneous brachial approach in left heart catheterization with 5 French catheters. Preliminary experience].
    Piscione F; Villari B; Focaccio A; Cappelli-Bigazzi M; Indolfi C; Chiariello M
    G Ital Cardiol; 1988 Jan; 18(1):17-22. PubMed ID: 3384243
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Outpatient coronary angiography using 7 French catheters in Singapore.
    Mak KH; Tan AT; Na KX; Kam RM; Koh PS
    Singapore Med J; 1995 Feb; 36(1):49-51. PubMed ID: 7570135
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safety of decreasing bedrest after coronary angiography.
    Baum RA; Gantt DS
    Cathet Cardiovasc Diagn; 1996 Nov; 39(3):230-3. PubMed ID: 8933962
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A randomized trial of 5 versus 7 French guiding catheters for transfemoral percutaneous coronary stent implantation.
    Büchler JR; Ribeiro EE; Falcão JL; Martinez EE; Büchler RD; Feres F; Maielo JR; Haddad N; Ramires JF; Ellis SG
    J Interv Cardiol; 2008 Feb; 21(1):50-5. PubMed ID: 18093100
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Outpatient heart catheterization. An analysis of experience accumulated over 10 months].
    Chaves AJ; Suarez DG; Cano MN; Maldonado G; Esteves CA; Braga SL; Feres F; Mattos LA; Centemero M; Sousa AG
    Arq Bras Cardiol; 1992 Nov; 59(5):369-72. PubMed ID: 1340736
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Ambulatory coronary arteriography with 5 French catheters: experience with 604 procedures].
    Tamburino C; Corcos T; Favereau X; Russo G; Giuffrida G
    Cardiologia; 1992 Mar; 37(3):203-6. PubMed ID: 1504964
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety and efficacy of a multipurpose coronary angiography strategy using the transradial technique.
    Sanmartin M; Esparza J; Moxica J; Baz JA; Iñiguez-Romo A
    J Invasive Cardiol; 2005 Nov; 17(11):594-7. PubMed ID: 16264204
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Percutaneous radial approach for coronary angiography].
    D'Urbano M; Cafiero F
    G Ital Cardiol; 1996 Oct; 26(10):1149-55. PubMed ID: 9005160
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Coronary transluminal angioplasty using 6-french diagnostic catheters. A preliminary study].
    Meyer P; Schmitt R; Durand P; Guarino L; Lena P; Gomez-Moreno J
    Arch Mal Coeur Vaiss; 1994 Apr; 87(4):491-7. PubMed ID: 7848038
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [One center's experience of coronary angioplasty with a 5 French catheter guide by a femoral approach at the same time as coronary angiography].
    Brasselet C; Metz D; Perotin S; Maillier B; Tassan-Mangina S; Deschildre A; Bonfils L; Jennessaux C; Blaise C; Elaerts J
    Arch Mal Coeur Vaiss; 2002 Apr; 95(4):269-74. PubMed ID: 12055765
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Coronary angiography by a radial artery approach: feasibility, learning curve. One operator's experience].
    Louvard Y; Pezzano M; Scheers L; Koukoui F; Marien C; Benaim R; Goy P; Lardoux H
    Arch Mal Coeur Vaiss; 1998 Feb; 91(2):209-15. PubMed ID: 9749247
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of 4 French catheters for quantitative coronary analysis: in vivo variability assessment using 6 French guiding catheters as reference scaling devices.
    Sanmartin M; Goicolea J; Castellanos R; Bravo M; Ocaranza R; Cuevas D; Mantilla R; Ruiz-Salmeron R
    J Invasive Cardiol; 2004 Mar; 16(3):113-6. PubMed ID: 15152158
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effectiveness of right or left radial approach for coronary angiography.
    Kawashima O; Endoh N; Terashima M; Ito Y; Abe S; Ootomo T; Ogata K; Honda H; Takizawa K; Miyazaki Y; Sugawara D; Komatsu M; Sawazi Y; Ozaki T; Uchimuro T; Meguro T; Isoyama S
    Catheter Cardiovasc Interv; 2004 Mar; 61(3):333-7. PubMed ID: 14988891
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.