These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 20839699)

  • 41. A cadaveric study of posterior dislocation after total hip replacement-effects of head diameter and acetabular anteversion.
    Ng FY; Zhang JT; Chiu KY; Yan CH
    Int Orthop; 2011 Mar; 35(3):325-9. PubMed ID: 20177891
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Influence of surgical experience on accuracy of acetabular cup positioning in total hip arthroplasty.
    Reize P; Geiger EV; Suckel A; Rudert M; Wülker N
    Am J Orthop (Belle Mead NJ); 2008 Jul; 37(7):360-3. PubMed ID: 18795183
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Measurement of acetabular cup anteversion with the circle theorem.
    Kosiyatrakul A; Luenam S; Chotanaphuti T
    J Med Assoc Thai; 2009 Dec; 92 Suppl 6():S128-33. PubMed ID: 20120674
    [TBL] [Abstract][Full Text] [Related]  

  • 44. New method for measuring acetabular component positioning with EOS imaging: feasibility study on dry bone.
    Journé A; Sadaka J; Bélicourt C; Sautet A
    Int Orthop; 2012 Nov; 36(11):2205-9. PubMed ID: 22949124
    [TBL] [Abstract][Full Text] [Related]  

  • 45. A three-dimensional parameterized and visually kinematic simulation module for the theoretical range of motion of total hip arthroplasty.
    Ji WT; Tao K; Wang CT
    Clin Biomech (Bristol); 2010 Jun; 25(5):427-32. PubMed ID: 20189695
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [Comparison of the acetabular orientation after minimally-invasive total hip arthroplasty with and without computer-navigation: a clinical report of 106 hip in 87 patients].
    Guo XZ; Dou BX; Liu Q; Huang Y; Zhou YX
    Zhonghua Yi Xue Za Zhi; 2007 Sep; 87(35):2489-93. PubMed ID: 18067812
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Role of the acetabular labrum and the iliofemoral ligament in hip stability: an in vitro biplane fluoroscopy study.
    Myers CA; Register BC; Lertwanich P; Ejnisman L; Pennington WW; Giphart JE; LaPrade RF; Philippon MJ
    Am J Sports Med; 2011 Jul; 39 Suppl():85S-91S. PubMed ID: 21709037
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Open reduction internal fixation and primary total hip arthroplasty of selected acetabular fractures.
    Boraiah S; Ragsdale M; Achor T; Zelicof S; Asprinio DE
    J Orthop Trauma; 2009 Apr; 23(4):243-8. PubMed ID: 19318866
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Arthroscopic treatment of acetabular labrum lesions: a series of 12 patients with a 4-year follow-up].
    Bonnomet F; Lefèbvre Y; Clavert P; Gicquel P; Marcillou P; Katzner M; Kempf JF
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Dec; 86(8):787-93. PubMed ID: 11148416
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Quantifying the Relationship Between the Transverse Acetabular Ligament and the Radiographic Teardrop.
    Harris MJ; Tam J; Fineberg SJ; Lucas PA; Zelicof SB
    J Arthroplasty; 2017 Jan; 32(1):296-299. PubMed ID: 27542856
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Bousquet's device in the treatment of recurrent dislocation of a total hip prosthesis. Apropos of 13 cases].
    Leclercq S; el Blidi S; Aubriot JH
    Rev Chir Orthop Reparatrice Appar Mot; 1995; 81(5):389-94. PubMed ID: 8560007
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [Application of acetabulum reinforcement ring for reconstructing acetabular defects in artificial hip replacement].
    Han W; Zhang H
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Feb; 23(2):201-4. PubMed ID: 19275103
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Pitfalls in the use of acetabular reinforcement rings in total hip revision.
    Bader R; Mittelmeier W; Zeiler G; Tokar I; Steinhauser E; Schuh A
    Arch Orthop Trauma Surg; 2005 Oct; 125(8):558-63. PubMed ID: 16189686
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Total hip replacement through a posterior approach using a 22 mm diameter femoral head : the role of the transverse acetabular ligament and capsular repair in reducing the rate of dislocation.
    Kumar V; Sharma S; James J; Hodgkinson JP; Hemmady MV
    Bone Joint J; 2014 Sep; 96-B(9):1202-6. PubMed ID: 25183591
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Modular necks improve the range of hip motion in cases with excessively anteverted or retroverted femurs in THA.
    Matsushita A; Nakashima Y; Fujii M; Sato T; Iwamoto Y
    Clin Orthop Relat Res; 2010 Dec; 468(12):3342-7. PubMed ID: 20473596
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Error in acetabular socket alignment due to the thick anterior pelvic soft tissues.
    Lee YS; Yoon TR
    J Arthroplasty; 2008 Aug; 23(5):699-706. PubMed ID: 18534380
    [TBL] [Abstract][Full Text] [Related]  

  • 57. In vitro investigation of the influence of pelvic tilt on acetabular cup alignment.
    Kalteis TA; Handel M; Herbst B; Grifka J; Renkawitz T
    J Arthroplasty; 2009 Jan; 24(1):152-7. PubMed ID: 18977116
    [TBL] [Abstract][Full Text] [Related]  

  • 58. The ligaments of the canine hip joint revisited.
    Casteleyn C; den Ouden I; Coopman F; Verhoeven G; Van Cruchten S; Van Ginneken C; Van Ryssen B; Simoens P
    Anat Histol Embryol; 2015 Dec; 44(6):433-40. PubMed ID: 25308720
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Posterolateral minimal incision for total hip replacement: technique and early results.
    Hartzband MA
    Orthop Clin North Am; 2004 Apr; 35(2):119-29. PubMed ID: 15062697
    [TBL] [Abstract][Full Text] [Related]  

  • 60. An approach to comparative anatomy of the acetabulum from amphibians to primates.
    Canillas F; Delgado-Martos MJ; Touza A; Escario A; Martos-Rodriguez A; Delgado-Baeza E
    Anat Histol Embryol; 2011 Dec; 40(6):466-73. PubMed ID: 21714810
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.